HomeCummins/OnanCummins/Onan MCE 5.0

Cummins/Onan MCE 5.0 Generator Set

The Cummins/Onan MCE 5.0 is a 5 kW (5 kVA) Unleaded, 88 Octane standby generator set powered by a Cummins/Onan MCE engine. It is available at 220 V and 110/220 V, single-phase and 50 Hz. It holds about 2.8 L (0.7 gal) of oil and 2.8 L (0.7 gal) of coolant. Starting uses 1 battery rated 360 CCA at 12 V.

5 kW
Standby
2.8 L
Oil capacity
1
Document types

How to read your Cummins/Onan serial & model number →

Service parts for the MCE 5.0

Grouped by system, with how many of each the parts manual calls for.

Oil system

1 required
518-0347Oil filtersee priceAmazon

Belts

1 required
M-1823Beltsee priceAmazon

Ignition

1 required
ES-I374Spark plugsee priceAmazon

Prices captured from merchant listings; some links are affiliate links. Confirm against your serial number before ordering.

Specifications

FuelUnleaded, 88 Octane
Frequency50.0 Hz
Standby power5 kW
Standby kVA5
Oil capacity2.8 L
Voltage options220 V, 110/220 V
Phase1
Power factor1.0
Battery cranking360 CCA
Battery voltage12 V
Battery quantity1
Coolant capacity2.8 L

Engine

Cummins/Onan MCE
Oil capacity2.8 L
Coolant capacity2.8 L
AspirationNaturally aspirated
Rated speed1800 rpm

Maintenance & consumables

for the Cummins/Onan MCE
ItemSpecCapacityPart #Interval
Air filter
Fuel filter35 hr
Oil filter518-0347 Amazon eBay
Batterycleaning, checking specific gravity, checking electrolyte level100 hr
BeltM-1823 Amazon eBay
Coolant2.8 L100 hr
Oil2.8 L250 hr
Spark plugES-I374 Amazon eBay

Common questions

What size generator is the Cummins/Onan MCE 5.0?

The Cummins/Onan MCE 5.0 is rated 5 kW standby (5.0 kVA).

What engine does the Cummins/Onan MCE 5.0 use?

The Cummins/Onan MCE 5.0 is powered by the Cummins/Onan MCE engine.

What fuel does the Cummins/Onan MCE 5.0 use?

The Cummins/Onan MCE 5.0 runs on Unleaded, 88 Octane.

How much oil does the Cummins/Onan MCE 5.0 take?

The Cummins/Onan MCE engine in the Cummins/Onan MCE 5.0 has an oil capacity of 2.8 liters.

What oil filter fits the Cummins/Onan MCE 5.0?

The Cummins/Onan MCE 5.0 uses oil filter part number 518-0347.

Troubleshooting

4

Symptoms & remedies

SymptomCauseRemedy
Engine Does Not Crank1. Control fuse F11 open. 2. Insufficient voltage for cranking due to: A. Terminal connection loose or corroded. 6. Battery dead or not charged 3. If engine cranks at set but not at the remote control panel, cause may be: A. Open circuit in remote B. Fault with remote start control switch. 4. If engine cranks at remote control panel but not at set, cause may be: A. Open circuit in wiring B. Fault in S11 switch between S11 switch and engine monitor PCB (A1 1). 5. There is voltage at terminal S, but not at S1 of starter solenoid K11 during START. 6. There is voltage at the starter motor terminal during START. 7. There is no voltage at terminal S of starter solenoid K11 during START.1. Replace fuse (10 ampere) A. Clean and tighten connections at battery, K11 start solenoid, and the starter motor. B. Check condition of battery and recharge or replace. 3. A. Check for continuity and correct if circuit is open. B. Replace remote start switch. 4. A. Check for continuity and correct if circuit is open. B. Replace S11 switch. 5. Check voltage at terminal 1 of solenoid K11. If it is not “0”, fix lead to ground. If voltage at terminal 1 of solenoid K11 is “0, replace faulty solenoid K11. 6. Service or replace defective starter. 7. Fix open circuit between K11 and engine monitor PCB (A1 1). If OK, replace defective engine monitor board (A1 1).
Engine Cranks But Does Not Start1. Faulty ignition due to defective spark plugs, plug wires, coil, or electronic module. 2. Faulty fuel system due to sticking choke, faulty fuel pump, plugged filter, or carburetor misadjustment 3. There is no voltage at igniter coil or fuel pump positive terminal.
Engine Starts But Stops When Start Switch is Released1. Fault condition. 2. Defective Fault Sensor. 3. Defective relay on engine monitor PCB (A1 1). 4. Defective fault circuit breaker CBI 2. 5. SOVAC not present across AC terminals of engine monitor PCB (A1 1) because of: A. Defective flash diode CR1 B. Defective generator
Low Battery, Generator Set Does Not Recharge1. Weak or discharged battery. 2. Load connected to battery while set is turned off. 3. Generator set not run long enough for built-in charger to recharge battery. 4. Defective VR2 voltage regulator. 5. Defective stator winding (B1 -B2).

Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing.

Repair guides

1

Step-by-step procedures compiled from the Cummins/Onan service manual for this model.

Parts

4
Part #DescriptionQtySystem
927-01Oil Filter24Oil filter Amazon eBay
ES-I374Spark plug gap checkSpark plug Amazon eBay
0-1174Figure 4-6. CHECKING BRUSH WEARService part / kit Amazon eBay
518-0347Sealant, ThreadService part / kit Amazon eBay

Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.

Fuel consumption

RatingLoadL/hgal/h
Standby100%5.01.3

Available documents

Service manual — 927-0505 Onan MCE Ensign series Marine Gensat Service Manual (09-1995) (Cummins/Onan)