Specifications
| Fuel | Diesel |
|---|---|
| Frequency | 60.0 Hz |
| Standby power | 200 kW |
| Standby kVA | 250 |
| Prime power | 180 kW |
| Controller | 2001 |
| Oil capacity | 26.5 L (28.0 US qt) |
| Voltage options | 277/480 V, 266/460 V, 120/240 V, 127/220 V, 120/208 V, 347/600 V |
| Phase | 3-Phase |
| Power factor | 0.8 |
| Battery voltage | 24 V |
| Coolant capacity | 37.2 L |
| Max ambient | 50 °C |
| Dimensions (L×W×H) | 2971×1003×1717 mm |
| Wet weight | 2007 kg |
| Sound level | 97.0 dBA @ 1 m |
Engine
| Oil capacity | 26.5 L (28.0 US qt) |
|---|---|
| Coolant capacity | 37.2 L |
| Displacement | 8.7 L |
| Aspiration | Turbocharged, AA Charge Cooled |
| Rated speed | 1800 rpm |
Filters for the Perkins 1306E87TA
2Engine-mounted filters the filter manufacturers list for this engine family. These come from the engine, not from this generator set’s own parts list, so confirm against your serial number before ordering.
Listed for this engine in only one kind of machine, so they may depend on how the engine was installed:
| System | Filter | Description | Cross-references | |
|---|---|---|---|---|
| Oil filter | P550367 | Lube Filter, Spin-On Full Flow | PERKINS 26540244, PERKINS P26540238, BALDWIN B7030, LOESING 025153 | buy |
| Oil filter | P502107 | Lube Filter, Spin-On Full Flow | NAPA 1374, LEYLAND-DAF (LDV) 12G24OO, MANITOU 136508, ORENSTEIN & KOPPEL 1499499 | buy |
Same engine, other brands
1 brandThe Perkins 1306E87TA in this set also powers 1 generator set sold under 1 other brand. Service parts and maintenance intervals for the engine are shared; enclosure, alternator, controller and ratings are not.
| Brand | Models |
|---|---|
| Olympian | D200P4 |
Service specifications
4| Type | Item | Value | Unit | Condition |
|---|---|---|---|---|
| Other | Frequency regulation | ±0.25% | for constant load, no load to full load | |
| Other | Waveform distortion | THD < 1.8% | at no load | |
| Speed | Overspeed limit | 2250 | rpm | |
| Voltage | Voltage regulation | ±0.5% | steady state from no load to full load |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Recommended fluids
| Fluid | Grade | Standard | Ambient | Capacity | Notes |
|---|---|---|---|---|---|
| Engine oil | API CF-4 | 26.5 L | Total oil capacity for D200P4 |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Common questions
What size generator is the Caterpillar D200P4?
The Caterpillar D200P4 is rated 200 kW standby (250.0 kVA).
What engine is in the Caterpillar D200P4?
The Caterpillar D200P4 is powered by the Perkins 1306E87TA engine.
Is the Caterpillar D200P4 diesel or gas?
The Caterpillar D200P4 runs on Diesel.
What is the oil capacity of the Caterpillar D200P4?
The Caterpillar D200P4 takes 26.5 L (28.0 US qt) of engine oil, per 0059bafc Caterpillar-Olympian-D200P4-spec-sheet.
How much coolant does the Caterpillar D200P4 hold?
The Caterpillar D200P4 cooling system holds 37.2 liters (9.8 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.
What is the continuous rating of the Caterpillar D200P4?
The Caterpillar D200P4 is rated 180 kW prime (225 kVA), against 200 kW standby.
What is the sound level of the Caterpillar D200P4?
The Caterpillar D200P4 is rated at 97.0 dBA at 1 m, per the manufacturer specification sheet.
What voltage does the Caterpillar D200P4 produce?
The Caterpillar D200P4 is offered in 277/480 V, 266/460 V, 120/240 V, 127/220 V, 120/208 V, 347/600 V, 3-Phase-phase.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| Prime | 50% | 30.5 | 8.06 |
| Prime | 75% | 412.2 | 11.1 |
| Prime | 100% | 55.5 | 14.66 |
| Standby | 50% | 33.6 | 8.9 |
| Standby | 75% | 46.4 | 12.3 |
| Standby | 100% | 61.26 | 16.18 |
Source — consumption: 0059bafc Caterpillar-Olympian-D200P4-spec-sheet.
Available documents