Home›Caterpillar›Caterpillar 3176

Caterpillar 3176 Generator Set

The Caterpillar 3176 is a diesel generator set powered by a Caterpillar 3176C engine. It holds about 28.5 L (7.5 gal) of oil and 10.2 L (2.7 gal) of coolant.

10.3 L
Displacement
28.5 L
Oil capacity
3
Document types

How to read your Caterpillar serial & model number →

Service parts for the 3176

Grouped by system, with how many of each the parts manual calls for.

Fuel system

1 required

Hydraulic system

1 required
9T0973Hydraulic filter$92.60eBay

Prices captured from merchant listings; some links are affiliate links. Confirm against your serial number before ordering.

Specifications

Fueldiesel
Oil capacity28.5 L

Engine

Caterpillar 3176C
Oil capacity28.5 L
Coolant capacity10.2 L
Displacement10.3 L
AspirationATAAC
Rated speed2100 rpm

Filters for the Caterpillar 3176C

7

Engine-mounted filters the filter manufacturers list for this engine family. These come from the engine, not from this generator set’s own parts list, so confirm against your serial number before ordering.

SystemFilterDescriptionCross-references
Oil filterP554005Lube Filter, Spin-On Full FlowCATERPILLAR 1R0716, CATERPILLAR 1W2660, NAPA 1792, BALDWIN BF46150-O FridayParts $41.73
Oil filterP551808Lube Filter, Spin-On Full FlowCATERPILLAR 1R1808, CATERPILLAR 1R808, NAPA 7792, BALDWIN B7299 KuduParts $80.00
Fuel filterP550625Fuel Filter, Spin-On SecondaryCATERPILLAR 1165436, CATERPILLAR 1R0762, NAPA 3640, BALDWIN BF7753 buy
Fuel filterP551311Fuel Filter, Spin-On SecondaryCATERPILLAR 1R0749, CATERPILLAR 3089679, BALDWIN BF7587, TAMROCK 019854051 KuduParts $147.00 FridayParts $151.84
Fuel / water separatorP551858Fuel Filter, Water Separator Spin-OnCATERPILLAR 1335673, CATERPILLAR 1700061, NAPA 3780, BALDWIN BF1265 FridayParts $39.00 KuduParts $48.00

Listed for this engine in only one kind of machine, so they may depend on how the engine was installed:

SystemFilterDescriptionCross-references
Coolant filterP554071Coolant Filter, Spin-OnCATERPILLAR 1112369, CATERPILLAR 1112370, NAPA 4071, WALGAHN-MOTORENTECHN 00811412 FridayParts $397.60
Coolant filterP554073Coolant Filter, Spin-OnCATERPILLAR 0C2000, CATERPILLAR 0C2017, NAPA 4073, VERSATILE 00104040 KuduParts $40.00

Maintenance & consumables

for the Caterpillar 3176C
ItemSpecCapacityPart #Interval
Fuel filterHigh Efficiency Fuel Filter1R-0750 Amazon eBay $33.80 eBay $33.80 NAPA $21.82 NAPA $21.82 KuduParts $17.00 FridayParts $29.50
Hydraulic filterFilter hydraulic/transmission9T0973 eBay $92.60 NAPA $151.86 KuduParts $75.00 FridayParts $77.02
OilSAE 15W-40—500 hr

Service intervals

12
ItemActionHoursMonthsNotes
Engine oil (S-O-S oil sample)Test125 hrSevere service occurs at high loads, in high temperatures, and in dusty conditions
Coolant (S-O-S coolant analysis Level 1)Test250 hrCat ELC - Every 250 Hours; also the recommended sampling interval for all conventional heavy-duty coolant/antifreeze and for commercial coolants that meet Cat EC-1
Engine crankcase oil (S-O-S oil sample)Test250 hrTable 6 S-O-S Oil Sampling Interval; severe applications may require a more frequent oil sampling interval
SCA (Supplemental Coolant Additive) concentrationTest250 hrTest the concentration of SCA or submit a coolant sample at 250 hour intervals or at PM Level 1 intervals; check at every oil change or every 250 hours, whichever occurs first
Coolant (S-O-S coolant analysis Level 2)Test500 hr12 moFirst service — For new systems, refilled systems, and converted systems that use Cat ELC or Cat DEAC; also every year; use the interval that occurs first
oilChange500 hr3000 Series service intervals increased to 500 hours as standard (3013C, 3024C, 3054, 3056)
Cat ELC Extender addition (cooling system)Other6000 hrTreat the cooling system with Cat ELC Extender at 6000 hours or one half of the coolant service life
Coolant (Cat ELC)Change12000 hr12000 service hours or six years; use the interval that occurs first
minor overhaulOther20000 hr3600 engines designed to run 20 000 hours between minor overhauls using No. 2 fuel
major overhaulOther40000 hr3600 engines designed to run 40 000 hours between major overhauls using No. 2 fuel
cylinder liners and pistonsOther80000 hr3600 cylinder liners and pistons designed for 80 000 hours using No. 2 fuel
Coolant (S-O-S coolant analysis Level 1 and Level 2)Test12 moCat DEAC - Yearly

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Service specifications

1
TypeItemValueUnitCondition
PressureUnit injector fuel injection pressure1240bar (18 000 psi)

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Recommended fluids

FluidGradeStandardAmbientCapacityNotes
CoolantCat DEACDiesel; 3,000 Service Hours or Three Years; annual S·O·SSM Level 2 coolant sampling and analysis
CoolantCat DEAC (Diesel Engine Antifreeze/Coolant)Acceptable coolant; commercial heavy-duty antifreeze/coolant must meet ASTM D4985 or ASTM D6210Conventional heavy-duty coolant/antifreeze. Caterpillar recommends a 1:1 mixture of water and glycol. Do not use a commercial coolant/antifreeze that only meets the ASTM D3306 specification. Do not use Cat SCA at the initial fill when Cat DEAC is used.
CoolantCat ELCDiesel; 12,000 Service Hours or Six Years; add Cat ELC Extender at 6,000 service hours or one half of service life; annual S·O·SSM Level 2 coolant sampling and analysis
CoolantCat ELC (Extended Life Coolant)Caterpillar EC-1 specification (preferred); also meets ASTM D4985, ASTM D6210, and ASTM D3306Service life of 12000 service hours or six years. Premixed ELC provides freeze protection to -37 C (-34 F); ELC Concentrate can be used to lower the freezing point to -52 C (-62 F). An Extender is the only additional maintenance needed at 6000 service hours or one half of the ELC service life. Cat ELC cooling systems can withstand contamination to a maximum of ten percent of conventional heavy-duty coolant/antifreeze and/or SCA.
CoolantCat NGECNatural Gas; 16,000 Service Hours or Three Years; use interval that occurs first
CoolantCat SCA (Supplemental Coolant Additive) with waterSCA concentration in a cooling system that uses SCA and water should be six to eight percent by volume; do not exceed the eight percent maximum concentration. If Cat SCA is not used, the commercial SCA must provide a minimum of 2400 mg/L or 2400 ppm (140 grains/US gal) of nitrites in the final coolant mixture when used with water, and a minimum of 1400 mg/L or 1400 ppm (82 grains/US gal) with heavy-duty coolant/antifreeze.
CoolantGlycol (ethylene glycol / propylene glycol)Propylene glycol coolant must meet ASTM D6210-04Ethylene glycol: 50 percent = freeze protection -37 C (-34 F), boil protection 106 C (223 F); 60 percent = -52 C (-62 F), 111 C (232 F). Propylene glycol: 50 percent = -32 C (-26 F), 106 C (223 F). Do not use propylene glycol in concentrations that exceed 50 percent; do not use ethylene glycol in concentrations that exceed 60 percent. All Caterpillar diesel engines equipped with air-to-air aftercooling (ATAAC) require a minimum of 30 percent glycol.
Engine oilCat DEO (Diesel Engine Oil) 10W-30 and 15W-40Cat ECF-1 (exceeds); API CI-4, API CI-4 PLUS, API CH-4, API CG-4, API CF (Cat DEO SAE 15W-40)Caterpillar oils are used to fill diesel engines at the factory. Non-Caterpillar commercial oils are second choice oils. Do not use API CF-4 oils in Caterpillar diesel engines. Do not use single grade API CF oils or multigrade API CF oils in 3500 Series, C175 Series and smaller DI diesel engines.
Engine oilCat NGEONatural Gas
Engine oilCommercial oils (DI engines)Cat ECF-1 required; API CG-4 multigrade acceptable; API CH-4, API CI-4 and API CI-4 PLUS acceptable only if the requirements of Cat ECF-1 are met; do not use API CF-4 oilsMinimum TBN must be 10 times the fuel sulfur level (ASTM D2896); minimum TBN of the oil is 5 regardless of a low fuel sulfur level. API CG-4 oils: do not exceed the standard oil drain interval.
Engine oilCommercial oils (PC engines)Cat ECF-1; API CH-4, API CI-4, API CI-4 PLUS (if Cat ECF-1 requirements met); API CG-4 multigrade; API CF-4 multigrade; API CFMinimum TBN of the oil that is used in PC engines must be 20 times the fuel sulfur level; minimum TBN of new oil is five. Change the oil when the TBN deteriorates to 50 percent of the original TBN.
Engine oilRe-refined base stock oilsAcceptable if they meet the performance requirements specified by Caterpillar; filtering is inadequate for producing high quality re-refined base stock oils.
Engine oilSynthetic base stock oilsAcceptable if they meet the performance requirements specified for the engine compartment. Caterpillar does not recommend the automatic extension of oil drain intervals for any type of oil.
Engine oilCat Arctic DEO SYN SAE 0W-30-40°C to 30°CEngine Crankcase; Industrial Engines
Engine oilSAE 0W-20-40°C to 10°CTable 1 Lubricant Viscosities for Ambient Temperatures (DI diesel engines)
Engine oilSAE 0W-30-40°C to 30°CTable 1 Lubricant Viscosities for Ambient Temperatures (DI diesel engines)
Engine oilSAE 0W-40-40°C to 40°CTable 1 Lubricant Viscosities for Ambient Temperatures (DI diesel engines)
Engine oilCat DEO SYN SAE 5W-40-30°C to 50°CEngine Crankcase; Industrial Engines
Engine oilSAE 5W-30-30°C to 30°CTable 1 Lubricant Viscosities for Ambient Temperatures (DI diesel engines)
Engine oilSAE 5W-40-30°C to 50°CTable 1 Lubricant Viscosities for Ambient Temperatures (DI diesel engines)
Engine oilCat DEO SAE 10W-30-18°C to 40°CEngine Crankcase; Industrial Engines
Engine oilSAE 10W-30-18°C to 40°CTable 1 Lubricant Viscosities for Ambient Temperatures (DI diesel engines); SAE 10W-30 is the preferred viscosity grade for the 3116, 3126, C7, C-9 and C9 diesel engines between -18 C (0 F) and 40 C (104 F)
Engine oilSAE 10W-40-18°C to 50°CTable 1 Lubricant Viscosities for Ambient Temperatures (DI diesel engines)
Engine oilCat DEO SAE 15W-40-9°C to 50°CEngine Crankcase; Industrial Engines
Engine oilSAE 15W-40-9°C to 50°CTable 1 Lubricant Viscosities for Ambient Temperatures (DI diesel engines)
Engine oilCat SAEO SAE 30API CF-4 category0°C to 40°CTable 2 - 3116 and 3126 Marine Engines with mechanical unit injection; factory fill has API CF-4 category and viscosity grade of SAE 30
Engine oilSAE 300°C to 40°CTable 3 Lubricant Viscosities for Ambient Temperatures - PC engines only
Engine oilCat SAEO SAE 40API CF-4 category5°C to 50°CTable 2 - 3116 and 3126 Marine Engines with mechanical unit injection. Caterpillar does not recommend the use of multigrade oils in the 3116 and 3126 Marine Diesel Engines that use mechanical unit injection.
Engine oilSAE 405°C to 50°CTable 3 Lubricant Viscosities for Ambient Temperatures - PC engines only
FuelBiodiesel blendsCaterpillar biodiesel specification, ASTM D6751, or EN 14214May be blended in amounts up to a maximum of 30 percent (models C6.6, C7, C9, C11, C13, C15, C18, C27, C32, 3114, 3116, 3126, 3176, 3196, 3208, 3306, C-9, C-10, C-12, 3406, C-15, C-16, C-18, 3456, 3408, 3412, 3500 Series, C175 Series, 3600 Series, C280 Series, CM20, CM25 and CM32); for 3003 through 3034, 3046, 3054, 3056, 3064, and 3066 engines, maximum ratio of 5% biodiesel to 95% acceptable diesel fuel. Caterpillar recommends a maximum of one year for fuel storage.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Procedures

3
Determining the cause of a plugged fuel filter (ice or wax) diagnostic
  1. Remove the fuel filters.
  2. Cut the fuel filters open.
  3. Inspect the fuel filter before the filter warms. The inspection will show that the filter is filled with particles of either ice or wax.
Changing to Cat ELC maintenance

⚠ Do not leave an empty SCA maintenance element on a system that is filled with ELC. The element housing may corrode and leak causing an engine failure.

⚠ Improper or incomplete rinsing of the cooling system can result in damage to copper and other metal components.

⚠ The cooling system cleaner must be thoroughly flushed from the cooling system. Cooling system cleaner that is left in the system will contaminate the coolant. The cleaner may also corrode the cooling system.

Tools: Caterpillar cleaner for cooling systems, 5P-3413 Pipe Sealant, Suitable containers to collect fluids

  1. Drain the coolant into a suitable container.
  2. Dispose of the coolant according to local regulations.
  3. If equipped, remove the empty SCA maintenance element and the element base. Plug the coolant lines or bypass the coolant lines.
  4. Flush the system with clean water in order to remove any debris.
  5. Use Caterpillar cleaner for cooling systems in order to clean the system. Follow the instructions on the label.
  6. Drain the cleaner into a suitable container. Flush the cooling system with clean water.
  7. In systems with heavy deposits, disconnect the hoses. Clean deposits and debris from the hoses and fittings. Install the hoses and tighten the hose fittings.
  8. Fill the cooling system with clean water and operate the engine until the engine is warmed to 49 C to 66 C (120 F to 151 F).
  9. Drain the cooling system into a suitable container and flush the cooling system with clean water.
  10. Repeat Steps 8 and 9 until the system is completely clean.
  11. Fill the cooling system with the Cat ELC.
  12. Operate the engine until the engine is warmed. While the engine is running, inspect the engine for leaks. Tighten hose clamps and connections in order to stop any leaks.
  13. Attach the Special Publication, PEEP5027, "Label" to the cooling system filler for the engine in order to indicate the use of Cat ELC.
Calculating the amount of lighter fuel required to modify the cloud point or the pour point operation
  1. Obtain the specification for the cloud point or the pour point of both fuels from your fuel supplier.
  2. Locate the cloud point or the pour point of the heavier fuel on the left side of the table. Mark the point on the table.
  3. Locate the cloud point or the pour point of the lighter fuel on the right side of the table. Mark the point on the table.
  4. Draw a line between the two points that were established. Label this line "A".
  5. Find the lowest outside temperature for machine operation on the left side of the table. Draw a horizontal line from this point until it intersects line "A". Label this new line "C".
  6. Mark the intersection of line "C" and line "A". Draw a vertical line to the bottom of the table. Label this line "B". The point at the bottom of line "B" reveals the percentage of lighter fuel that is

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Common questions

Which engine powers the Caterpillar 3176?

The Caterpillar 3176 is powered by the Caterpillar 3176C engine.

What fuel does the Caterpillar 3176 use?

The Caterpillar 3176 runs on diesel.

How much oil does the Caterpillar 3176 take?

The Caterpillar 3176C engine in the Caterpillar 3176 has an oil capacity of 28.5 liters.

What is the cooling system capacity of the Caterpillar 3176?

The Caterpillar 3176 cooling system holds 10.2 liters (2.7 US gallons) for the engine, per the manufacturer specification sheet.

What fuel filter fits the Caterpillar 3176?

The Caterpillar 3176 uses fuel filter part number 1R-0750.

Parts

14
Part #DescriptionQtySystem
1R-0749Fuel Secondary - ADV1Fuel filter Amazon Amazon eBay $135.88 eBay $135.88 NAPA $28.51 NAPA $28.51 KuduParts $17.00 FridayParts $47.50
1R-0750High Efficiency Fuel Filter1Fuel filter Amazon eBay $33.80 eBay $33.80 NAPA $21.82 NAPA $21.82 KuduParts $17.00 FridayParts $29.50
1R-0751High Efficiency Fuel Filter1Fuel filter Amazon Amazon eBay $20.19 eBay $48.88 NAPA $22.53 NAPA $22.53 KuduParts $36.00 FridayParts $37.23
1R-0755High Efficiency Fuel Filter1Filter Amazon eBay $34.99 eBay $96.90 NAPA $82.67 NAPA $82.67 KuduParts $54.00 FridayParts $71.99
1R-0756High Efficiency Fuel FilterFuel filter Amazon eBay $18.99 eBay $18.99 NAPA $34.69 KuduParts $33.00 FridayParts $34.98
1R-0766High Efficiency Fuel Filter1Fuel filter Amazon eBay $50.07 NAPA $61.32 KuduParts $41.00 FridayParts $43.25
9T0973Filter hydraulic/transmissionHydraulic filter eBay $92.60 NAPA $151.86 KuduParts $75.00 FridayParts $77.02
M-4626474Gasket Set - Rear StructureGasket Amazon eBay
M-4652364Gasket Set - Oil Cooler & LinesGasket Amazon eBay
PEHP7069-01Reman Water PumpWater pump Amazon eBay
RE558676ALTERNATOR1Alternator Amazon eBay $156.95 NAPA $326.29 FridayParts $168.00
AEHQ5438-01Replaces AEHQ5438Service part / kit Amazon eBay
AEHQ5487-02Replaces AEHQ5487-011Service part / kit Amazon eBay
AEHQ5574-01Replaces AEHQ5574Service part / kit Amazon eBay

Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.

Available documents

Engine spec — LECH3874-02 (Caterpillar)Engine spec — Spec Sheet - Cat 3176C Propulsion (Caterpillar)Engine spec — cat-3176c-propulsion (Caterpillar)Engine spec — lehh6334 (Caterpillar)Engine spec — lehh8135 (Caterpillar)Engine spec — lehh8348-01 (Caterpillar)Engine spec — lehm6388 (Caterpillar)Engine spec — leht5386 (Caterpillar)Engine spec — leht5387 (Caterpillar)Engine spec — lehw4181 (Caterpillar)Engine spec — lfhh5400 (Caterpillar)Engine spec — lfhh5448 (Caterpillar)Engine spec — lfhh6261 (Caterpillar)Engine spec — lghh5400 (Caterpillar)Engine spec — llhh5400 (Caterpillar)Engine spec — lshh6258 (Caterpillar)Engine spec — lshh6261 (Caterpillar)Parts manual — Caterpillar Engines (Caterpillar)Parts manual — KMP-Brand®Parts-Guide-Suitable-for-Caterpillar®By-Product (Caterpillar)Parts manual — pedp7026 (Caterpillar)Service manual — Caterpillar Diesel Engine Fluid Recommendations (Caterpillar)

This page was generated from the 21 manufacturer documents above by automated extraction; every figure shown is copied from one of them. How the data is compiled.

Full service, cheapest listings

Priced items from this model's own parts manual.

Fuel filter 1R-0750$21.82
Hydraulic filter 9T0973$92.60
2 priced items$114.42