HomeAirmanAirman SDG60S-3B1

Airman SDG60S-3B1 Generator Set

The Airman SDG60S-3B1 is a 150 kW (165 kVA) Diesel oil standby generator set powered by a Isuzu BH-6UZ1X engine. It is available at 200/220 V and 400/440 V, 3-phase, 50 Hz and rated 197 A. It holds about 41 L (10.8 gal) of oil and 47.5 L (12.5 gal) of coolant, with a maximum ambient rating of 40 °C. Starting uses 2 group-95 batteries at 12 V. The set measures 3×1×1 mm (0.1×0.0×0.0 in), weighs about 3 kg (7 lb) and produces 88 dBA at 7 m. An integrated tank holds 400 L (105.7 gal), roughly 8 hours of runtime.

150 kW
Standby
9.839 L
Displacement
41.0 L
Oil capacity
1
Document types

Compare with other 150–155 kW Diesel generators →

Specifications

FuelDiesel oil
Frequency50.0 Hz
Standby power150 kW
Standby kVA165
Prime power142 kW
EmissionsJPN Stage 3
ControllerAutomatic Voltage Regulator
Oil capacity41.0 L
AlternatorIsuzu BH-6UZ1X (6-pole, Class F insulation)
Voltage options200/220 V, 400/440 V
Phase3-phase
Rated current197 A
Power factor0.8 (lagging) / Single-phase 1.0
Circuit breaker197 A
Battery group95D31Rx2
Battery voltage12V V
Battery quantity2
Coolant capacity47.5 L
Max ambient40 °C
Dimensions (L×W×H)3×1×1 mm
Dry weight3 kg
Sound level88.0 dBA @ 7 m
Fuel tank400.0 L
Tank runtime8.0 hr

Engine

Isuzu BH-6UZ1X
Oil capacity41.0 L
Coolant capacity47.5 L
Displacement9.839 L
AspirationTurbo-Charged, Intercooled
Rated speed1 rpm

Filters & service parts

model family
ItemSpecCapacityPart #Interval
Air filterAir Filter500 hr find
Fuel filterFuel Filter500 hr find
Oil filterOil Filter500 hr find
OilEngine Oil38.0 L500 hr

Compiled from this model's family documentation — may include parts for closely-related variants. Confirm the exact part for your serial number.

Common questions

What is the power rating of the Airman SDG60S-3B1?

The Airman SDG60S-3B1 is rated 150 kW standby (165.0 kVA).

What engine does the Airman SDG60S-3B1 use?

The Airman SDG60S-3B1 is powered by the Isuzu BH-6UZ1X engine.

What fuel does the Airman SDG60S-3B1 use?

The Airman SDG60S-3B1 runs on Diesel oil.

What is the oil capacity of the Airman SDG60S-3B1?

The Isuzu BH-6UZ1X engine in the Airman SDG60S-3B1 has an oil capacity of 41.0 liters.

What alternator does the Airman SDG60S-3B1 use?

The Airman SDG60S-3B1 uses a Isuzu BH-6UZ1X alternator. It has 6 poles. Insulation class F.

Parts

1
Part #DescriptionQtySystem
95D31Rx2Battery2Battery PartsGeek

Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.

Fuel consumption

RatingLoadL/hgal/h
Prime50%18.56.5
Prime75%26.19.2
Standby50%15.85.5
Standby75%22.88.0

Available documents

Parts manual — 2305 generators sdg series 36p no04 en (Airman)