The Waukesha L1616-GSIU is a 26.4 L 12-cylinder turbocharged engine rated at 1800 rpm, producing up to 700 kW. It powers generator sets from Cummins/Onan, including the WF series and WK Series. It holds 25 L (6.6 gal) of oil and 25 L (6.6 gal) of coolant.

Also known as: Waukesha L1616-GSIU

Part of the Waukesha L1616 engine family — 4 variants share parts & fitment.

26.4 L
Displacement
12
Cylinders
1800 rpm
Rated speed
700 kW
Gross power

Engine specifications

Oil capacity25.0 L
Coolant capacity25.0 L
Displacement26.4 L
Cylinders12
AspirationTurbocharged
Rated speed1800 rpm
Gross power700 kW

Generator sets powered by this engine

2
Cummins/Onan WF seriesCummins/Onan WK Series

Common problems

11
  • Overspeed lamp lights - no fault condition exists.
    Fix: Replace overspeed circuit board.
  • Overcrank fault lamp lights and engine stops cranking after approximately 75 seconds.
    Fix: See engine service manual for troubleshooting fuel system, ignition system, etc. After correcting problem, reset the engine monitor by moving run-stop-remote switch to stop position, and depressing reset switch. PENN STATE. Move and hold run-stop-remote switch to OFF. Press reset, release and move switch to ON.
  • Overcrank fault lamp lights after engine has run for approximately 75 seconds.
    Fix: Replace start-disconnect circuit board.
  • Low oil pressure lamp lights after engine is running.
    Fix: Check: a. Oil level - engine will shut down after approximately 12-1/2 seconds if oil pressure is low.
  • Low oil pressure fault lamp lights - no fault condition exists.
    Fix: Be certain that no fault condition exists. Disconnect lead 30 from T B l l inside control box (refer to wiring diagram). If low oil pressure lamp still lights, remove and replace engine monitor plug-in printed circuit board.
  • High engine temperature lamp lights as soon as engine starts.
    Fix: Check for defective sensor or actual high temperature condition.
  • High engine temperature lamp lights after engine is running.
    Fix: Check for: a. Defective thermostat/thermostats. b. Low coolant level. c. Defective high engine temperature sensor.
  • Fault lamp lights immediately after engine starts.
    Fix: Check for: a. overspeed condition as engine starts. b. high temperature condition. c. faulty high engine temperature sensor or overspeed switch. d. faulty starter disconnect.
  • Fault lamp lights and engine stops cranking after approximately 75 seconds.
    Fix: See engine service manual for troubleshooting fuel system, ignition system, etc. After correcting problem, reset the engine monitor by holding run-stop-remote switch in stop position, and depressing reset switch. Release and return to run position.
  • Fault lamp lights afterengine is running.
    Fix: Check the following: a. Oil level-engine will shut down after approximately 12-1/2 seconds if low oil pressure sensor does not open. b. Oil pressure sensor may be defective. c. High engine temperature - caused by low coolant level, faulty thermostat, etc. d. Faulty high engine temperature sensor. e. Faulty starter disconnect.
  • Fault lamp lights - no fault condition exists.
    Fix: Be certain that no fault condition exists. Disconnect lead 30 and 31 from T B l l inside control box (refer to wiring diagram). If fault lamp still lights with leads disconnected, remove and replace engine monitor plug-in printed circuit board.

Compiled from service & troubleshooting documentation across every generator set that uses the Waukesha L1616-GSIU.

Maintenance schedule

ItemSpecCapacityPart #Interval
Air filterAir Filter—200 hr
Fuel filterFuel Filter—200 hr
Oil filterOil Filter232AI489200 hr Amazon eBay
BatteryBattery—200 hr
BeltDrive Belt—200 hr
CoolantCoolant25.0 gallons—200 hr
OilEngine Oil25.0 gallons232AI490200 hr Amazon eBay PartsGeek $17.97
Spark plugSpark Plug—200 hr

Pooled from every document that names this exact engine — confirm the interval and part number against your unit's serial number.

Service intervals

3
ItemActionHoursMonthsNotes
Crankcase oilChange100 hrUnder dust and dirt conditions: change crankcase oil at least every 100 operating hours
CoolantCheckFirst service — On initial run, check coolant level several times and add liquid to compensate for air pockets
Generating plantOtherFirst service — Break-in: run plant at 50% rated load for the first 1/2 hour after reaching operating temperature

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Service specifications

28
TypeItemValueUnitCondition
ClearanceGenerator support to skid base shim clearance.035inchesadded to each side of the skid base
OtherBHP at 1,800 rpm (nominal)7001,800 rpm
OtherBattery charging rate, initial2 to 10ampereswhen plant first starts
OtherBattery electrolyte specific gravity, diluted (hot locations)1.225ambient above 90°F
OtherBattery electrolyte specific gravity, full charge1.275
OtherCranking limiter time limit45seconds
OtherMaximum crank time30secondsdo not crank longer at one time
PressureLow oil pressure cut-out (shutdown)14psishuts down if oil pressure drops below
PressureNormal engine oil pressure40-50psiat operating temperature
Speed50 cycle operating speed1500rpm
Speed60 cycle operating speed1800rpm
SpeedAC frequency regulation5%
SpeedGovernor regulation5%
SpeedOverspeed shutdown2100rpmshuts down if plant speed exceeds
TemperatureCity water cooling flow adjustment (water temperature)165-195°Fmaintain while viewing water temperature gauge
TemperatureHigh water temperature cut-out215°Fshutdown above
TemperatureNormal operating water/coolant temperature160-180°F
TorqueAlternator torque REF 130in.-lb.
TorqueAlternator torque REF 230-35ft.-lb.
TorqueAlternator torque REF 3450-500ft.-lb.
TorqueAlternator torque REF 4150-200ft.-lb.
TorqueAlternator torque REF 5195-200ft.-lb.
TorqueAlternator torque REF 6275-280ft.-lb.
TorqueAlternator torque REF 7120-125ft.-lb.
TorqueAlternator torque REF 825ft.-lb.min.
TorqueAlternator torque REF 97-10ft.-lb.
TorqueDiodes (rotating rectifier)30in. lb.or finger tight plus a quarter turn
VoltageAC voltage regulation±2%

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Recommended fluids

FluidGradeStandardAmbientCapacityNotes
CoolantClean soft water51.0 gallonsCooling system capacity including radiator. Use a good rust and scale inhibitor; use ethylene glycol base antifreeze if exposed to freezing temperatures. Maintain 165°F to 195°F.
Engine oilMIL-L-2104B military specification (oils designated for MS or DG service)25.0 U.S. gallonsApproximate oil pan capacity; extra oil may be required for oil filter or accessories. Do not use multi-viscosity oil such as 10W-30; do not mix brands or grades. Use oil of recommended viscosity according to ambient temperature.
FuelNatural gasRefer to Waukesha manual for fuel specifications; keep fuel supply clean

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Procedures

8
Testing Rotating Rectifier Assembly (Diodes) diagnostic

Tools: ohmmeter

  1. Remove access cover from exciter end of the generator.
  2. Isolate each diode by disconnecting one end from its connection point.
  3. Use an ohmmeter to measure resistance in the individual diode; reverse the ohmmeter leads and repeat.
  4. A good diode should have a high resistance value one way and a low value when leads are reversed; replace if not good.
  5. Check all diodes in accordance with step 3.
Align Generator Support to Skid Base installation

⚠ The generator support must be aligned to the skid base to prevent premature generator bearing failure; failure to do so could void the warranty.

Tools: feeler gauge or dial indicator, jackscrews

  1. Set plant on its mounting foundation using vibration isolators; secure skid base to foundation.
  2. Remove the two mounting bolts and shims securing the generator support to the skid base.
  3. Use the mounting bolts as jackscrews in the threaded holes; remove tension and allow generator to hang free.
  4. Measure clearance from top of skid base to each generator support mounting surface.
  5. Add .035 inches to each side of the skid base; this determines the amount of shims required.
  6. Turn jackscrews to allow clearance for placing shims between skid base and generator support.
  7. Lower generator on shims and recheck total clearance (must equal base-to-support clearance plus .035 in.).
  8. Remove jackscrews and install as mounting bolts through generator support, shims and skid base; secure and lock.
Battery Electrolyte Dilution for Hot Locations maintenance

⚠ Avoid skin or clothing contact with electrolyte; dispose of it in a safe manner.

Tools: hydrometer or filler bulb

  1. Fully charge the battery.
  2. With battery still on charge, draw off all electrolyte above the plates in each cell; do not pour off.
  3. Refill each cell with distilled water to normal level.
  4. Continue charging for one hour at a 4- to 6 ampere rate.
  5. Test each cell; if specific gravity is still above 1.225, repeat steps 2, 3 and 4.
Out-Of-Service Protection (More Than 30 Days) maintenance
  1. Run plant until thoroughly warm.
  2. Drain oil from oil base while still warm; refill and attach a warning tag stating oil viscosity used.
  3. Remove each spark plug; pour one ounce of rust inhibitor (or SAE #50 oil) into each cylinder; install spark plug.
  4. Service air cleaners as outlined in Waukesha manual.
  5. Clean throttle linkage and protect by wrapping with a clean cloth.
  6. Plug exhaust outlets to prevent entrance of moisture, bugs, dirt, etc.
  7. Wipe entire unit; coat parts susceptible to rust with a light film of grease or oil.
  8. If battery is used, disconnect and follow standard battery storage procedure.
  9. Provide a suitable cover for the entire unit.
Starting the Plant operation
  1. Press the RUN-STOP switch to its RUN position, holding in contact to crank the engine.
  2. Do not crank for more than 30 seconds at one time; investigate any failure to start.
  3. If engine fails to crank, check that the cranking limiter switch is closed.
Stopping the Plant operation
  1. If conditions permit, disconnect electrical load and allow the plant to run a few minutes at no load.
  2. Press the RUN-STOP switch to its STOP position to stop the plant.
Brush Assembly Removal (Battery Charging DC Alternator) repair
  1. Remove the three No. 10-24 screws which fasten voltage regulator to DC alternator; remove regulator to gain access to phenolic cover, disconnecting leads as required.
  2. Remove the two No. 8-32 screws on phenolic cover and lift out cover and gasket.
  3. Pull brush assembly straight up and lift out.
  4. For reassembly, reverse procedure.
Replacement of Diodes repair

⚠ Do not over-torque the diode.

Tools: proper size wrenches

  1. Use proper size wrenches to hold the body of the diode while removing the nut attaching it to the heat sink.
  2. Push the diode free of its mounting hole in the heat sink.
  3. Be sure new diode is installed in the same position (direction) as defective diode; parts have directional arrows.
  4. Insert new diode into its mounting hole in the heat sink.
  5. Using nut and washer provided, secure diode, being careful not to allow it to turn while tightening; do not over-torque.
  6. Connect leadwires to appropriate terminals.
  7. Replace access cover.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Voltage reconnection

VoltagePhaseConnectionLeadsNotes
120/24034 Wire DeltaL0 (neutral), L1, L2, L3Supplies 120 volt single phase and 240 volt three phase. For 3 phase operation L0 is not used; L1 and L2 are 'hot' terminals and L0 is the neutral (can be grounded if required). If no 3 phase output used, usable 1 phase output is 2/3 of 3 phase KVA.
Three phase33 Phase, 3 WireL1, L2, L3No terminal is grounded. Connect separate load wires to each plant terminal L1, L2 and L3. Single phase obtained from any two terminals (L1-L2, L1-L3, L2-L3); load on any one single-phase circuit must not be greater than 1/3 rated capacity.
Three phase, 4 wire (Wye)3Wye connectedL0 (grounded neutral), L1, L2, L3Single phase voltage is the lower nameplate voltage; three phase voltage is the higher nameplate voltage. Connect neutral (white) to L0 and hot (black) to L1, L2 or L3; not more than 1/3 rated capacity from any one circuit.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Parts cataloged across the Waukesha L1616 family

109
Part #DescriptionCategory
302A61Ammeter, ChargeAmmeter
302P640Ammeter, AC (Check Ammeter Scale - Select According to Rating)Ammeter
302P641Ammeter, AC (Check Ammeter Scale - Select According to Rating)Ammeter
302P642Ammeter, AC (Check Ammeter Scale - Select According to Rating)Ammeter
A9562-12 VOLT BATTERIESBattery
332A795Ammeter, Charge (30-0-30)Block
332AI006Block, TerminalBlock
332AI009Block, TerminalBlock
301D2903Box, ControlBox
130-0465BraceBrace
130-0466BraceBrace
301A2393Bracket, Relay MountingBracket
322P69Bracket, Mounting - EngineBracket
110-1168Bracket & Nipple AssemblyBracket nipple
505-0270Bushing, Reducer (2 x 1-1/4")Bushing reducer
503-0059ClampClamp
330A5Cover - BOICover
505-0453Elbow (90° )Elbow 90
130-0740Flange AssemblyFlange assembly
232AI490Engine OilFluid
301C2906Frame. Control Panel MountingFrame
232AI817Onan OE FilterFuel filter
A955Fill pipe for underground fuel tankFuel tank
193B112Gauge, Water TemperatureGauge
193B194Gauge, Oil PressureGauge
502-0391Adapter, HoseHose
503-0359Hose (1-5/8" I.D. x 3 ' )'Hose
503-0512Hose (2-7/8" I.D. x 18" )Hose
322P74Knob, RheostatKnob
322-17Bulb, (2) Panel ( I ) PilotLamp
322-81Lamp, PanelLamp
309-0243Valve, Control - Temperature RegulatingMarsh valve
302B213Meter, Frequency (60 Hertz)Meter
302B234Meter, Frequency (50 Hertz)Meter
302P465RESISTOR-STABILIZINGMeter
302P466For 220/380-V, 3-Ph, 60-Cycle (Model H)Meter
302P468For 120/208-V,120/240-V, & 347/600-V 3PH. 50 Cy!. (825-Ohm, 75-Watt)Meter
302P469For 220/380-V, 3Ph. 50-CycleMeter
302P470For 277/480-V, 3-Ph, 50-Cyclo (5-P!)Meter
402A70Mount, Rubber - Control Box.FrameMount
505-0328Nipple ( 3 x 6 " )Nipple
505-0604Nipple (3 x 9-3/4" )Nipple
505-0615Nipple (3 x 24" )Nipple
505-0437Nipple, Half (1-1/4 x 4")Nipple half
130-0687StandpipeService part / kit
232A90Shim (0.020 inch thick, 2 x 3 gauge metal)Service part / kit
232AI489Laminated ShimService part / kit
301A1914Bracket, Panel StopService part / kit
302A6ISwitch, Panel LightService part / kit
302P422Scale Reads 0-600Service part / kit
302P467For 277/480 Volt,3 Phase, 60 Cycle Plants.Service part / kit
304A262RESISTOR. FIXED 50-Ohm, 10 WattService part / kit
304A446RESISTOR. FIXED 150-Ohm, 10 WanService part / kit
307-0839Valve, SolenoidService part / kit
307-0844Valve, SolenoidService part / kit
307A655Relay, Emergency LatchService part / kit
307A899Relay, Oil PressureService part / kit
307P778Spring, Relay Hold-downService part / kit
308-2Switch, Panel LightService part / kit
308PI38Strip, Blk. Marker (55 through 62)Service part / kit
30IAI685Block, Terminal (8-Place)Service part / kit
30ID2I24Cover, Output Terminal BoxService part / kit
320AI04Limiter, CrankingService part / kit
323-52SocketService part / kit
332AI005Block, Terminal (20-Place)Service part / kit
501-0186Line, FlexibleService part / kit
501-0187Line, FlexibleService part / kit
504-0003Cock, Drain (1/4 NPT)Service part / kit
504-0062Valve, ReliefService part / kit
505-0004Nipple, Pipe (1.0 x 1.50)Service part / kit
505-0041Elbow, Pipe ( 1 " x 90°)Service part / kit
505-0088Nipple, Pipe (1 x 4-1/2")Service part / kit
505-0178-Nipple; HalfService part / kit
505-0258Nipple (1-1/4 x 3")Service part / kit
505-0394Bushing, Reducer (2 x 1")Service part / kit
505-0669TeeService part / kit
505-0679Nipple (3 x 12" )Service part / kit
800-0091Part 800-0091Service part / kit
850-0040Washer, Lock - Spring (1/4")Service part / kit
850-0060Screw, Cap - Hex Head (5/16-18 X 7-1/2" )Service part / kit
862-0001Nut, Hex (1/4-20)Service part / kit
862-0005Nut (1/2-13)Service part / kit
I93BI94Gauge, Oil PressureService part / kit
TB12terminal block for remote connections and common alarm (inside control)Service part / kit
TB21TERMINAL BLOCKService part / kit
301C2908Panel. ControlPanel
301C2915Panel, ControlPanel
304A305Panel Only, Lower Cont.Panel
301A2905Plate. Control Box - SidePlate
301B2904Plate. Control Box - TopPlate
308-3Plate, On-Off SwitchPlate
322-73Receptacle, Panel LampReceptacle
322P73Receptacle, Panel LampReceptacle
307P820Relay, Adjustabe Start Disconnect & Crankshaft LimiterRelay
320B259Relay, CrankingRelay
304A66Resistor, 4xELIResistor
322-65Resistor. Adjustable - 45,000 Ohm, lOWatt (277/480 V o l t )Resistor
308-13Rheostat, Voltage AdjustmentRheostat
337-44Strap, GroundStrap
332AI134Strip,. Terminal Block MarkerStrip
308P138Switch, Run-Stop-RemoteSwitch
308P139Switch, Voltage & Current SelectorSwitch
309P253THEHCOSTATThehcostat
333PI3BTheHCostatThehcostat
302B645Transformer, Current (Check Transformer Nameplate - Select According to Rating)Transformer
302P643Transformer, Current (Check Transformer Nameplate - Select According to Rating)Transformer
302P644Transformer, Current (Check Transformer Nameplate - Select According to Rating)Transformer
315B292Transformer, Potential (120/208 V o l t Plants)Transformer
302P421Scale Reads 0-300Voltmeter

Parts cataloged across all variants of this engine family — verify the exact part fits your specific variant and serial number before ordering.

Common questions

What is the oil capacity of the Waukesha L1616-GSIU?

The Waukesha L1616-GSIU engine has an oil capacity of 25.0 liters.

What is the displacement of the Waukesha L1616-GSIU?

The Waukesha L1616-GSIU has a displacement of 26.4 liters with 12 cylinders.

Which generators use the Waukesha L1616-GSIU engine?

The Waukesha L1616-GSIU powers 2 generator set(s), including Cummins/Onan WF series, Cummins/Onan WK Series.

How often should you change the oil in the Waukesha L1616-GSIU?

The Waukesha L1616-GSIU oil change interval is every 200 hours.

What is a common problem with the Waukesha L1616-GSIU engine?

A commonly reported issue on generators using the Waukesha L1616-GSIU is: Overspeed lamp lights - no fault condition exists.. Fix: Replace overspeed circuit board..