Home›Engines›Volvo Penta TAD1641GE-B

Volvo Penta TAD1641GE-B Engine

The Volvo Penta TAD1641GE-B is a 16.12 L 6-cylinder turbocharged, charge air-cooled engine rated at 1800 rpm, producing up to 565 kW. It powers generator sets from Kohler and MTU, including the 500REOZVC, 6R0269 DS450 and 6R0269 DS500. It holds 48 L (12.7 gal) of oil and 33 L (8.7 gal) of coolant.

Also known as: Volvo TAD1641GE-B

Part of the Volvo Penta TAD1641 engine family — 3 variants share parts & fitment.

16.12 L
Displacement
6
Cylinders
1800 rpm
Rated speed
565 kW
Gross power

Engine specifications

Oil capacity48.0 L
Coolant capacity33.0 L
Displacement16.12 L
Cylinders6
AspirationTurbocharged, Charge Air-Cooled
Rated speed1800 rpm
Gross power565 kW

Parts cataloged across the Volvo Penta TAD1641 family

49
Part #DescriptionCategory
7746012Air filterAir filter
7746032Fuel filterFuel filter
SPN16FUEL FILTER DIFF P pressure difference over fuel filterFuel filter
SPN95FUEL FILTER DIFF P pressure difference over fuel filterFuel filter
SPN97WATER IN FUEL water in fuelFuel filter
3803637Injector/UIInjector
7746022Oil filterOil filter
SPN99OIL FILTER DIFF P pressure difference over oil filterOil filter
AV133539-03GPart for 500REOZT exIVService part / kit
AV137912-01GPart for 500REOZT exIVService part / kit
CL130110-200Hotstart Pre heaterService part / kit
CM302/CM403Automatik-PaketService part / kit
CM307-CM407Analoge Anzeige der WerteService part / kit
EN04Pumpe für ÖlwechselService part / kit
FD05Diesel-Vorfilter mit AbscheiderService part / kit
FMI00HIGH LEVEL SHUTDOWN high level shutdownService part / kit
FMI01LOW LEVEL SHUTDOWN low level shutdownService part / kit
FMI15HIGH LEVEL WARNING high level warningService part / kit
FMI16HIGH LEVEL ALARM high level alarmService part / kit
FMI17LOW LEVEL WARNING low level warningService part / kit
FMI18LOW LEVEL ALARM low level alarmService part / kit
GM41339Cylinder head (includes items 2--34)Service part / kit
GM41427Rocker arm shaft (includes item 2)Service part / kit
GM65855Cylinder head (includes 2--34)Service part / kit
GM65981Rocker arm shaftService part / kit
GM78736Rocker armService part / kit
SPN100OIL PRESSURE oil pressureService part / kit
SPN101CRANKCASE PRESS crankcase pressureService part / kit
SPN105INTAKE MANIF TEMP intake manifold temperatureService part / kit
SPN106AIR INLET PRESSURE air inlet pressureService part / kit
SPN110COOLANT TEMP coolant temperatureService part / kit
SPN111COOLANT LEVEL coolant levelService part / kit
SPN158BATT VOLTAGE battery voltageService part / kit
SPN171AMBIENT AIR TEMP ambient air temperatureService part / kit
SPN172AIR IN TEMP air in temperatureService part / kit
SPN174FUEL TEMP fuel temperatureService part / kit
SPN175OIL TEMP oil temperatureService part / kit
SPN190SPEED speedService part / kit
SPN51THROTTLE POS throttle positionService part / kit
SPN52INTERCOOL TEMP intercooler temperatureService part / kit
SPN94FUEL PRESS fuel pressureService part / kit
SPN98OIL LEVEL oil levelService part / kit
TAD1641GEEngine ModelService part / kit
X25.1to be wired for the remote start switch.Service part / kit
X25.2to be wired for the remote start switch.Service part / kit
X25.3TerminalsService part / kit
X25.4TerminalsService part / kit
SPN102TURBO BOOST PRESS turbo boost pressureTurbocharger
SPN104TURBO OIL PRESS turbo oil pressureTurbocharger

Parts cataloged across all variants of this engine family — verify the exact part fits your specific variant and serial number before ordering.

Also used in

1
  • Volvo Penta TAD1641GE — Engine

Other equipment known to use this engine, via filter-application cross-reference — useful for sourcing parts even when your exact machine isn't listed elsewhere on this page.

Common questions

What is the oil capacity of the Volvo Penta TAD1641GE-B?

The Volvo Penta TAD1641GE-B engine has an oil capacity of 48.0 liters.

What is the displacement of the Volvo Penta TAD1641GE-B?

The Volvo Penta TAD1641GE-B has a displacement of 16.12 liters with 6 cylinders.

Which generators use the Volvo Penta TAD1641GE-B engine?

The Volvo Penta TAD1641GE-B powers 3 generator set(s), including Kohler 500REOZVC, MTU 6R0269 DS450, MTU 6R0269 DS500.