Engine specifications
| Oil capacity | 46.4 L |
|---|
| Coolant capacity | 44.0 L |
|---|
| Displacement | 15.9 L |
|---|
| Aspiration | Turbocharged, Intercooled |
|---|
| Rated speed | 1800 rpm |
|---|
Service intervals
15| Item | Action | Hours | Months | Notes |
|---|
| System | Test | 1 hr | | ToCI quarterly: exercise system under full load for 1 hour |
| Battery | Test | | 6 mo | Load-test battery at each semi-annual visit |
| Coolant antifreeze | Change | | 12 mo | NCCI/RCI: antifreeze change once per year during contract term |
| Engine tune-up | Other | | 12 mo | Annual: engine tune-up with parts |
| Fuel filters | Change | | 12 mo | Annual: change fuel filters |
| Generator sets and associated systems | Inspect | | 6 mo | Semi-annual inspection, testing and preventive maintenance (default unless Appendix A states otherwise) |
| Load bank | Test | | 12 mo | Annual four (4) hour load bank test / emergency service operation with four (4) hours full load test once per year |
| Lube oil | Change | | 12 mo | CMC/HCF: additional services on second visit - lube, oil and filter change |
| Lube oil analysis | Test | | 12 mo | Annual: lube oil analysis |
| Oil | Change | | 12 mo | NCCI/RCI: oil shall be changed once every 12 months |
| Oil filter, fuel filter and air filter | Change | | 12 mo | NCCI: change once every 12 months during the contract period |
| Primary and bypass lube filters | Change | | 12 mo | Annual: change primary and bypass lube filters |
| Transfer switch | Lubricate | | 12 mo | ToCI annual: check, clean and lubricate transfer switches and breakers |
| Valve clearance | Adjust | | 12 mo | ToCI annual: check valve clearance |
| Water filters | Change | | 12 mo | Annual: change water filters |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Service specifications
5| Type | Item | Value | Unit | Condition |
|---|
| Other | Exercise under full load | 1 | hour | ToCI quarterly |
| Other | Full load test duration | 4 | hours | Once per year |
| Other | Load bank data recording interval | 15 | minutes | During load bank test |
| Other | Load bank test load level | 80 | % of generator nameplate capacity | 4-hour resistive load bank test |
| Other | Load bank test profile | 2 hours at 50%, 1 hour at 75%, 1 hour at 100% | | Annual four (4) hour load bank test |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Recommended fluids
| Fluid | Grade | Standard | Ambient | Capacity | Notes |
|---|
| Engine oil | meeting manufacturer's specs | | | | Add crankcase oil (grade meeting manufacturer's specs) to correct level (SCI) |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Procedures
11Automatic Transfer Switch Semi-Annual Service maintenance
- Verify proper operation of exerciser clock; adjust if necessary.
- Provide visual inspection of all contacts and connection points.
- Perform building load test if practical and inspect for proper transfer and re-transfer.
- Verify operation of all control lamps.
Battery and Battery Charger System Semi-Annual Service maintenance
- Clean all battery terminals; verify integrity of cables and connectors.
- Load-test battery.
- Measure specific gravity of each battery cell.
- Inspect electrolyte level and add fluid if necessary.
- Verify proper operation and float voltage of external battery charger.
- Verify and record output of engine alternator.
Controls Semi-Annual Service maintenance
- Verify and record output voltage and adjust voltage regulator, if necessary.
- Calibrate control meters.
- Verify and record output frequency and adjust governor, if necessary.
- Verify operation of all control panel lamps.
- Inspect for any loose connections, terminals or discoloration.
Coolant System Semi-Annual Service maintenance
- Inspect all clamps, verify condition of all hoses and identify any leaks.
- Verify proper operation of engine water jacket heater.
- Test coolant freeze point and verify coolant level.
- Test coolant additive package for proper corrosion inhibitors.
- Inspect belt condition and tension; correct as required.
- Inspect radiator core for visual blockage or obstructions.
- Inspect for proper operation of intake louvers.
- Verify proper operation of remote radiator and belt condition.
Cooling System Semi-Annual Service (SCI) maintenance
- Visual inspection of Radiator/Heat exchanger for leaks, damage and obstructions.
- Add coolant to correct level.
- Inspect radiator cap, gasket and sealing surface.
- Visual inspection of water pump and cooling system gaskets for leaks.
- Inspect belts for cracking and fraying.
- Check water jacket heater for proper operation and adjust thermostat setting as needed.
- Check belt tension.
- Inspect flexible water connections for cracking, leaks and pliability.
- Inspect pulleys for excessive wear.
- Analyze coolant for proper antifreeze percentage.
- Analyze coolant conditioner level and add supplemental coolant additive as needed.
- Tighten hose clamps as needed.
- Lubricate fan drive with bearing lubricant.
Engine Semi-Annual Service maintenance
- Verify and record oil pressure and water temperature.
- Test all safety shutdown circuits and alarms (overspeed, overcrank, low oil pressure, high water temp, low coolant level).
- Inspect air intake system (air filter, crankcase breather, turbocharger).
- Inspect muffler system and drain condensation trap; verify rain cap operation.
- Inspect engine starting system; verify cable integrity and connections.
- Inspect exhaust flex coupling and piping for leaks and proper connection.
- Check for abnormal vibration or noise.
- Inspect spark plugs, plug wires and distributor.
Fuel System Semi-Annual Service maintenance
- Inspect all fuel lines and hoses for leaks and general condition.
- Inspect day tank and float assembly for proper operation and leaks.
- Inspect fuel pump for leaks.
- Verify proper operation of governor and governor linkage.
- Check fuel level in primary supply tank.
- Drain water and sediment from fuel filter and fuel supply tanks.
Generator Semi-Annual Service maintenance
- Inspect and lubricate generator end bell bearing.
- Inspect brushes, brush holders and commutators.
- Inspect cooling screen and general condition of alternator.
- Inspect for abnormal vibration.
- Verify connections and insulation condition.
- Verify proper operation of shunt trip on mainline circuit breaker.
Lubrication System Semi-Annual Service (SCI) maintenance
- Add crankcase oil (grade meeting manufacturer's specs) to correct level.
- Inspect oil heater for proper operation and leaks.
- With engine running, check for excessive crankcase blow-by.
- Visually inspect front and rear crankshaft seals and lubrication system gaskets for leaks.
- Check crankcase breather, inspect hose and connections.
- Take oil sample and perform oil analysis.
Optional Load Bank Testing maintenance
- Perform 4-hour resistive load bank test at 80% of generator nameplate capacity.
- Record all performance data at fifteen minute intervals including oil pressure, water temperature, voltage and frequency.
- Identify proper operation of fuel system, cooling system and overall condition of engine/generator set.
- Load bank testing shall be performed with no interruption to the normal power supply.
Starting System Semi-Annual Service (SCI) maintenance
- Check electrolyte level and add as needed.
- Check and record battery charger amperage.
- Check battery charger and adjust float rate for optimum battery performance and life.
- With engine running, check and record alternator for proper charge rate.
- Check for proper cranking termination upon engine start.
- Clean lead acid battery terminals and apply corrosion inhibitor.
- Tighten battery cable connections as needed.
- Inspect and tighten starter motors, connections and wiring.
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Parts cataloged across the MTU 8V2000 family
2| Part # | Description | Category |
|---|
| 343259 | Element, air cleaner | Air filter |
| 291502 | Hose, 90 deg. elbow, 5.50 in. OD | Hose |
Parts cataloged across all variants of this engine family — verify the exact part fits your specific variant and serial number before ordering.
Common questions
What is the oil capacity of the MTU 8V2000 G81 R083-7K36?
The MTU 8V2000 G81 R083-7K36 engine has an oil capacity of 46.4 liters.
What is the displacement of the MTU 8V2000 G81 R083-7K36?
The MTU 8V2000 G81 R083-7K36 has a displacement of 15.9 liters.
Which generators use the MTU 8V2000 G81 R083-7K36 engine?
The MTU 8V2000 G81 R083-7K36 powers 2 generator set(s), including Kohler 500ROZD, MTU 500 DS-4.