The MTU 16V 4000 G23 is a 76.3 L 20-cylinder exhaust turbocharging (etc) and charge air cooling (cac) engine rated at 1500 rpm. It powers generator sets from MTU and Talles, including the 16 V 4000 G23, 16V4000 DS2250, DP 2145 D5S FW and DS 2285 D5S FW. It holds 300 L (79.3 gal) of oil and 260 L (68.7 gal) of coolant.
Also known as: MTU 16V 4000 G23
Part of the MTU 16V4000 engine family — 66 variants share parts & fitment.
| Oil capacity | 300.0 L |
|---|---|
| Coolant capacity | 260.0 L |
| Displacement | 76.3 L |
| Cylinders | 20 |
| Aspiration | Exhaust turbocharging (ETC) and charge air cooling (CAC) |
| Rated speed | 1500 rpm |
Shared across brands: MTU, Talles
Compiled from service & troubleshooting documentation across every generator set that uses the MTU 16V 4000 G23.
| Item | Action | Hours | Months | Notes |
|---|---|---|---|---|
| Engine coolant | Change | 12 mo | If engine is out of service for more than one year, change engine coolant and charge-air coolant | |
| Valve gear | Lubricate | 6 mo | Lubricate valve gear every 6 months (out-of-service >3 months procedure) |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Type | Item | Value | Unit | Condition |
|---|---|---|---|---|
| Clearance | Centrifugal oil filter maximum layer thickness of oil residues | 45 | mm | if exceeded, shorten maintenance interval |
| Clearance | Valve clearance adjustment trigger deviation | 0.1 | mm | if deviation from reference value exceeds this |
| Clearance | Valve clearance deviation from reference value (adjustment threshold) | 0.1 | mm | |
| Other | Cold start capability air temperature (w/o start aid, w/o preheating, case A) | 10 | °C | |
| Other | Compressed-air tank condensate drain pressure drop | must not exceed 1 | bar | |
| Other | Coolant preheating temperature (min.) | 32 | °C | |
| Other | Engine coolant pump relief bore - permissible coolant discharge | up to 10 | drops per hour | |
| Other | Engine coolant pump relief bore - permissible oil discharge | up to 5 | drops/hour | |
| Other | Permissible coolant discharge (coolant pump relief bore) | up to 10 | drops/hour | |
| Other | Permissible oil discharge (coolant pump relief bore) | up to 5 | drops/hour | |
| Pressure | Final compression pressure | 24 to 28 | bar | at 120 rpm |
| Pressure | Fuel prefilter differential pressure (flush filter element threshold) | 0.3 | bar | engine running at full load or rated power |
| Pressure | Fuel prefilter differential pressure flush limit | ≥ 0.3 | bar | engine at full load / rated power |
| Pressure | Fuel pressure at engine supply connection, max. (starting) | 1.5 | bar | when engine is starting |
| Pressure | Fuel pressure at engine supply connection, min. (starting) | -0.1 | bar | when engine is starting |
| Pressure | Lube oil operating pressure before engine (12V 4000 Gx3, continuous 3B) | 5.0 to 6.0 | bar | |
| Pressure | Lube oil operating pressure before engine (16V 4000 Gx3, standby 3D) | 4.2 to 6.5 | bar | |
| Pressure | Lube oil operating pressure before engine, from/to | 5.0 to 7.0 | bar | 12V engines |
| Speed | Firing speed | 80 to 120 | rpm | |
| Speed | Firing speed, from/to | 80 to 120 | rpm | |
| Temperature | Coolant preheating, preheating temperature (min.) | 32 | °C | |
| Temperature | Coolant temperature after engine, alarm | 102 | °C | |
| Temperature | Coolant temperature after engine, shutdown | 104 | °C | |
| Temperature | Coolant temperature at engine connection (outlet to cooling equipment) | 100 | °C | |
| Temperature | Jacket water heater adjustable thermostat | 32 to 55 | °C | |
| Torque | Battery-charging generator drive belt screw (2) | 60 to 65 | Nm | |
| Torque | Battery-charging generator drive belt tension screw (1) | 42 | Nm | |
| Torque | Belt drive screw (1) | 42 | Nm | |
| Torque | Belt drive screw (2) | 60 to 65 | Nm | |
| Torque | Centrifugal oil filter clamp | 8 to 10 | Nm | |
| Torque | Centrifugal oil filter cover nut | 5 to 7 | Nm | |
| Torque | Centrifugal oil filter rotor cover nut | 35 to 45 | Nm | |
| Torque | Crankcase breather cover screws | 10 ±2 | Nm | oil separator / diaphragm cover |
| Torque | Crankcase breather oil separator cover screws | 10 Nm -2 | Nm | |
| Torque | Cylinder head cover screws | 42 | Nm | |
| Torque | Engine oil drain plugs (2) and (3) | 100 Nm +10 | Nm | |
| Torque | HP fuel line - injector side | 20 Nm +5 | Nm | |
| Torque | HP fuel line - rail side | 30 Nm +5 | Nm | |
| Torque | HP fuel line, injector side | 30 ±5 | Nm | |
| Torque | HP fuel line, rail side | 30 ±5 | Nm | |
| Torque | Injector adapter | 100 ±10 | Nm | |
| Torque | Injector adapter (pretighten) | 5 to 10 | Nm | |
| Torque | Injector hold-down clamp screw (pretighten) | 5 to 10 | Nm | |
| Torque | Injector hold-down screw and adapter | 100 Nm +10 | Nm | |
| Torque | Oil drain plugs (2) and (3) | 100 ±10 | Nm | equipment carrier |
| Torque | Valve clearance locknut | 90 +9 | Nm | holding adjusting screw firm |
| Torque | Valve clearance locknut | 90 ±9 | Nm | holding adjusting screw firm |
| Valve clearance | Exhaust valve clearance (short rocker arm) | 0.5 | mm | cold engine |
| Valve clearance | Exhaust valves (short rocker arm) | 0.5 | mm | cold engine |
| Valve clearance | Inlet valve clearance (long rocker arm) | 0.2 | mm | cold engine |
| Valve clearance | Inlet valves (long rocker arm) | 0.2 | mm | cold engine |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Fluid | Grade | Standard | Ambient | Capacity | Notes |
|---|---|---|---|---|---|
| Coolant | MTU Fluids and Lubricants Specification A001061 | 160.0 liters | Engine coolant capacity, engine side (without cooling equipment): 12V = 160 liters, 16V = 260 liters. Coolant antifreeze content max. 50%. | ||
| Engine oil | MTU Fluids and Lubricants Specification A001061 | 260.0 liters | 12V engines: total engine oil capacity at initial filling 260 liters (standard oil system); 16V engines: 300 liters | ||
| Fuel | Diesel #2 | Recommended Fuel for diesel gensets (e.g. DS30, DS40, DS50, DS80, DS100, DS125, DS150, DS180, DS200, DS230, DS250, DS275, DS300, DS350, DS400, DS450, DS500) | |||
| Fuel | Diesel fuel | Only fuels of the specified quality required to achieve emission limits must be used | |||
| Grease | Kluthe Hakuform 30-10 / Emulgier | Grease for injector O-rings; part X00029933 | |||
| Other | Cleaner Hakutex 60 | Cleaner for centrifugal oil filter rotor parts | |||
| Other | Isopropyl alcohol | Cleaning agent for connectors / contacts; part 461 81 | |||
| Other | Optimoly Paste White T | Assembly paste for injector sealing ring / nozzle retaining nut; part 40477 |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Code | Name | Meaning | Severity | Action |
|---|---|---|---|---|
| 003 | HI T-Fuel | Preliminary warning: fuel temperature too high. | Warning | Contact Service. |
| 004 | SS T-Fuel | Main warning: fuel temperature too high; engine stop. | Shutdown | Contact Service. |
| 005 | HI T-Charge Air | Preliminary warning: charge-air temperature too high. | Warning | Reduce power. Check intercooler. |
| 006 | SS T-Charge Air | Main warning: charge-air temperature too high; engine stop. | Shutdown | Reduce power. Check intercooler. |
| 009 | AL L1 T-Coolant Intercooler | Preliminary warning: coolant temperature in intercooler too low. | Warning | Reduce power. |
| 010 | AL L2 T-Coolant Intercooler | Main warning: charge-air coolant temperature too high; engine stop. | Shutdown | Reduce power. |
| 015 | LO P-Lube Oil | Preliminary warning: lube oil pressure too low. | Warning | Check oil level, top up as necessary (Page 146). |
| 016 | SS P-Lube Oil | Main warning: lube oil pressure too low; engine will be shut down. | Shutdown | Check oil level; attempt to restart engine (Page 57). |
| 019 | HI T-Exhaust A | Preliminary warning: exhaust gas temperature (A-side) too high. | Warning | Check cabling (Page 171); Contact Service. |
| 020 | SS T-Exhaust A | Main warning: exhaust gas temperature (A-side) too high. Engine stop. | Shutdown | Check cabling; Contact Service. |
| 021 | HI T-Exhaust B | Preliminary warning: exhaust gas temperature (B-side) too high. | Warning | Check cabling; Contact Service. |
| 022 | SS T-Exhaust B | Main warning: exhaust gas temperature (B-side) too high. Engine stop. | Shutdown | Check cabling; Contact Service. |
| 023 | LO Coolant Level | Alarm configuration limit value 1; coolant level too low. | Warning | Check coolant level in expansion tank (Page 153). |
| 024 | SS Coolant Level | Alarm configuration limit value 2; coolant level too low. | Shutdown | Check coolant level in expansion tank (Page 153). |
| 025 | HI P-Diff. Lube Oil | Preliminary warning: oil filter differential pressure too high. | Warning | Replace oil filter (Page 150). |
| 026 | HI P-Diff. Lube Oil | Preliminary warning: Oil filter differential pressure too high | Warning | Replace oil filter |
| 027 | HI Leak Fuel Level | Preliminary warning: leak-off fuel level too high. | Warning | Check fuel system; Contact Service. |
| 029 | HI ETC 2 idle speed | Idle speed of ETC 2 too high | Warning | Contact Service |
| 030 | SS Engine Speed | Alarm configuration limit value 2; engine overspeed; reduced fuel injection. | Shutdown | Acknowledge alarm; attempt to restart engine. |
| 031 | HI ETC 1 overspeed | Preliminary warning: speed of primary turbocharger too high | Warning | Contact Service |
| 032 | SS ETC 1 overspeed | Speed of primary turbocharger too high | Shutdown | 1. Automatic power reduction by engine control system. 2. Check air filters. |
| 036 | HI ETC 2 overspeed | Preliminary warning: speed of secondary turbocharger too high | Warning | 1. Reduce power. 2. Contact Service. |
| 037 | SS ETC 2 overspeed | Main warning: speed of secondary turbocharger too high; Fuel limitation to a fixed value | Shutdown | 1. Reduce power. 2. Contact Service. |
| 038 | AL ETC Synchro Fault | Synchronization error between ETCs 1 and 2 | Warning | 1. Reduce power. 2. Contact Service. |
| 039 | AL ETC 2 cut-in failure | ETC2 failed to cut in | Warning | 1. Reduce power. 2. Contact Service. |
| 044 | L1 Coolant Level Intercooler | Intercooler coolant level too low. | Warning | Check coolant level (Page 161). |
| 051 | HI T-Lube Oil | Preliminary warning: lube oil temperature too high. | Warning | Reduce power. |
| 052 | SS T-Lube Oil | Main warning: lube oil temperature too high; engine stop. | Shutdown | Reduce power; check engine oil level (Page 146). |
| 057 | LO P-Coolant | Preliminary warning: coolant pressure too low. | Warning | Check coolant circuit. |
| 058 | SS P-Coolant | Main warning: coolant pressure too low; engine stop or reduced injection quantity. | Shutdown | Automatic engine shutdown; check coolant level. |
| 063 | HI P-Crankcase | Preliminary warning: crankcase pressure too high. | Warning | Reduce power; replace oil separator element (Page 114). |
| 064 | SS P-Crankcase | Main warning: crankcase pressure too high; engine stop. | Shutdown | Replace oil separator element; Contact Service. |
| 065 | LO P-Fuel | Preliminary warning: fuel supply pressure too low. | Warning | Check fuel lines for leaks; clean/flush fuel prefilter; replace filter element; replace fuel filter. |
| 066 | SS P-Fuel | Main warning: fuel supply pressure too low; engine stop. | Shutdown | Check fuel lines; clean/flush/replace fuel prefilter element; replace fuel filter. |
| 067 | HI T-Coolant | Preliminary warning: coolant temperature too high. | Warning | Reduce power. |
| 068 | SS T-Coolant | Main warning: coolant temperature too high; engine stop. | Shutdown | Allow engine to cool down; check coolant cooler; restart engine; Contact Service. |
| 081 | AL Rail Leakage | Pressure gradient in rail too low during starting or too high during stopping; HP system leaky, air in system | Warning | Contact Service |
| 082 | HI P-Fuel (Common Rail) | Rail pressure > reference value; DBR fuel limitation, start of injection readjusted towards late | Warning | Contact Service |
| 083 | LO P-Fuel (Common Rail) | Rail pressure < reference value; DBR fuel limitation; suction restrictor faulty or leakage in HP fuel system | Warning | Contact Service |
| 085 | HI T-Recirculation | Preliminary warning: Recirculation temperature too high | Warning | Reduce power. |
| 086 | HI T-Recirculation | Main warning: Recirculation temperature too high | Warning | Reduce power. |
| 089 | AL Stalling Engine | Alarm configuration limit value; engine speed too low. | Warning | Check for additional messages. |
| 090 | SS No Idling Speed | Alarm configuration limit value; idling speed was not attained. | Shutdown | Contact Service. |
| 091 | SS No Runup Speed | Alarm configuration limit value; runup speed was not attained. | Shutdown | Contact Service. |
| 092 | SS No Starter Speed | Starter speed was not attained; termination of starting sequence; starter rotates too slowly or not at all. | Shutdown | Contact Service. |
| 093 | SS T-Preheat | Main warning: preheating temperature too low; coolant temperature too low for engine start; engine start interlock active. | Shutdown | Check preheater. |
| 094 | LO T-Preheat | Preheating temperature too low: coolant temperature too low for engine start. | Warning | Check preheater. |
| 095 | AL Prelubrication Fault | Oil priming failure | Warning | Check oil priming system. |
| 102 | AL Consumption Meter Faulty | Consumption meter faulty | Warning | Contact Service |
| 104 | AL Eng Hours Counter Defect | Hourmeter faulty | Warning | Contact Service |
| 118 | LO ECU Supply Voltage | Preliminary warning: supply voltage too low. | Warning | Check ECU supply voltage; Contact Service. |
| 119 | LOLO ECU Supply Voltage | Main warning: supply voltage too low. | Shutdown | Check ECU supply voltage; Contact Service. |
| 120 | HI ECU Supply Voltage | Preliminary warning: supply voltage too high. | Warning | Check ECU supply voltage; Contact Service. |
| 121 | HIHI ECU Supply Voltage | Main warning: supply voltage too high. | Shutdown | Check ECU supply voltage; Contact Service. |
| 122 | HI T-ECU | Preliminary warning: temperature in ECU too high. | Warning | Reduce power; improve engine room ventilation. |
| 134 | 15V POS ECU DEFECT | Internal voltage (-15 VDC) faulty; automatic engine shutdown | Shutdown | Replace ECU. |
| 136 | 15V NEG ECU DEFECT | Internal voltage (-15 VDC) missing; automatic engine shutdown | Shutdown | Contact Service. |
| 139 | L1 TE BUFFER TEST | Supply voltage of temperature sensors faulty | Warning | 1. Check sensors. 2. Replace ECU. 3. Contact Service. |
| 140 | TE BUF. ECU DEFECT | Supply voltage of temperature sensors faulty | Shutdown | 1. Check sensors. 2. Replace ECU. 3. Contact Service. |
| 142 | BANK1 ECU DEFECT | Power output stage for control of the solenoid valves on bank 1 is faulty; Engine does not start | Shutdown | Replace ECU. |
| 144 | BANK2 ECU DEFECT | Power output stage for control of the solenoid valves on bank 2 is faulty; Engine does not start | Shutdown | Replace ECU. |
| 145 | 15V_GOOD ECU DEFECT | Power supply faulty; automatic engine shutdown | Shutdown | Replace ECU. |
| 146 | L1 AD-TEST1 SUPPLY | Supply voltage A/D converter too low | Warning | Replace ECU. |
| 147 | AD-TEST1 ECU DEFECT | Electronic fault; automatic engine shutdown | Shutdown | Replace ECU. |
| 148 | L1 AD-TEST2 SUPPLY | Supply voltage A/D converter too low | Warning | Replace ECU. |
| 149 | AD-TEST2 ECU DEFECT | Internal electronic fault; automatic engine shutdown | Shutdown | Replace ECU. |
| 150 | L1 AD-TEST3 SUPPLY | Internal electronic fault; automatic engine shutdown | Warning | Replace ECU. |
| 151 | AD-TEST3 ECU DEFECT | Internal electronic fault; automatic engine shutdown | Shutdown | Replace ECU. |
| 173 | MODULE WRITE LIMIT REACHED | EEPROM write limit reached. | Info | Contact Service. |
| 176 | AL LifeData Not Avail | No (appropriate) LifeData backup system available, ECU reset after expiration of time-out period | Warning | Contact Service. |
| 177 | AL LifeData restore incomplete | CRC faulty during a data upload to ADEC | Warning | Contact Service. |
| 180 | AL CAN1 Node Lost | Connection to one node on CAN bus 1 failed. | Warning | Contact Service. |
| 181 | AL CAN2 Node Lost | Connection to one node on CAN bus 2 failed. | Warning | Contact Service. |
| 182 | AL CAN Wrong Parameters | Incorrect parameter values entered in data record | Warning | Contact Service. |
| 183 | AL CAN No PU-Data | CAN mode selected requiring communication with PU data module; required PU data module not available or not valid | Warning | Contact Service. |
| 184 | AL CAN PU-Data Flash Error | Programming error when copying a received PU data module into the Flash module | Warning | Contact Service. |
| 186 | CAN1 BUS OFF | Severe fault on Default CAN bus; automatic change-over to Redundant CAN bus. | Warning | Contact Service. |
| 187 | AL CAN1 Error Passive | CAN controller 1 has signalled a warning | Warning | 1. Inspect CAN bus for short circuit and rectify. 2. Check shielding. 3. Contact Service. |
| 188 | AL CAN2 Bus Off | CAN controller 2 is in Bus-Off status; automatic changeover to CAN 1; short circuit, massive interference or Baud rate incompatibility | Warning | 1. Inspect CAN bus for short circuit and rectify. 2. Check shielding. 3. Contact Service. |
| 189 | AL CAN2 Error Passive | CAN controller 2 has signalled a warning | Warning | 1. Inspect CAN bus for short circuit and rectify. 2. Check shielding. 3. Contact Service. |
Showing the first 80 of 176 codes.
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Tools: Feeler gauge Y20010128, Torque wrench 60-320 Nm F30047446, Ring socket, 24 mm F30039526
Tools: Rigid endoscope Y20097353
⚠ Spring/circlip/tensioning roller preload. Risk of injury!
⚠ Hot oil. Oil can contain combustion residues which are harmful to health.
⚠ Compressed air. Risk of injury!
Tools: Torque wrench 6-50 Nm F30027336
⚠ Hot oil. Oil can contain combustion residues which are harmful to health.
Tools: Torque wrench 6-50 Nm F30027336
⚠ Unguarded rotating and moving engine components. Risk of serious injury - danger to life!
Tools: Barring tool F6555766, Ratchet F30006212
⚠ Unguarded rotating and moving engine components. Risk of serious injury - danger to life!
⚠ Coolant is hot and under pressure. Risk of injury and scalding!
⚠ Cold coolant in hot engine can cause thermal stress.
⚠ Hot oil. Oil can contain combustion residues which are harmful to health.
Tools: Torque wrench F30027337, Ratchet adapter F30027341
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Voltage | Phase | Connection | Leads | Notes |
|---|---|---|---|---|
| 208V | 3 | 12 LEAD WYE | Example from MTU 4R0063 GS30 | |
| 240V | 1 | 12 LEAD | Example from MTU 4R0063 GS30 SYSTEM RATINGS connection row | |
| 240V | 1 | 4 LEAD | Example from MTU 4R0063 GS30 | |
| 240V | 3 | 12 LEAD DELTA | Example from MTU 4R0063 GS30 | |
| 380/400/415 | Standard scope voltage, 50 Hz (S1600/S2000/S4000) | |||
| 380/440/480 | Standard scope voltage, 60 Hz (S1600/S2000/S4000) | |||
| 380V | 3 | 12 LEAD WYE | Example from MTU 4R0063 GS30 | |
| 400/230 | Standard scope voltage, 1600 series, 50 Hz | |||
| 440/480 | Alternator voltages, 60 Hz | |||
| 480/277 | Standard scope voltage, 1600 series, 60 Hz | |||
| 480V | 3 | 12 LEAD WYE | Example from MTU 4R0063 GS30 | |
| 600V | 3 | 4 LEAD WYE DOUBLE DELTA | Example from MTU 4R0063 GS30 |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Part # | Description | Category |
|---|---|---|
| 274623 | Cleaner, Air | Air filter |
| 274821 | Air Cleaner | Air filter |
| 347667 | Air Cleaner Assembly | Air filter |
| 347810 | Air Cleaner | Air filter |
| WM00076 | Air filter element | Air filter |
| 12V4000Gx3-07 | Battery | Battery |
| 12V4000Gx3-06 | Belt | Belt |
| 347423 | Belt, Poly V | Belt |
| 347429 | V-Belt | Belt |
| 12V4000Gx3-02 | Engine oil filter | Filter |
| 12V4000Gx3-03 | Fuel filter | Filter |
| 12V4000Gx3-04 | Air filter | Filter |
| 12V4000Gx3-01 | Engine oil | Fluid |
| 12V4000Gx3-05 | Coolant | Fluid |
| WM00086 | Easy-change fuel filter | Fuel filter |
| 347442 | Gasket, Inlet | Gasket |
| 5272030080 | GASKET | Gasket |
| X00021730 | GASKET | Gasket |
| 347437 | Tube, Upper Radiator | Hose |
| 347440 | Tube, Lower Radiator | Hose |
| X-507-6 | Lower Radiator Hose | Hose |
| X-6006-4 | Upper Radiator Hose | Hose |
| 279260 | Filter, oil | Oil filter |
| WM00067 | Oil filter element | Oil filter |
| 243273 | Fuse, 3 amp | Service part / kit |
| 283645 | Fuse, 15 Amp | Service part / kit |
| 291207 | Fuse, 1.5 amp | Service part / kit |
| 291740 | Rectifier or Coil | Service part / kit |
| 328725 | Voltage Regulator | Service part / kit |
| A-347395-1 | Engine Assembly, 2000 kW | Service part / kit |
| A-347485 | Radiator Assembly | Service part / kit |
| 007603014102 | COPPER SEALING RING | Seal |
| 007603030101 | COPPER SEALING RING | Seal |
| 05132155 | SEAL | Seal |
| 52420300037 | THERMAL ACTUATOR DICHTRING AUS FKM | Seal |
| 700429070000 | O-RING | Seal |
| 700429072000 | O-RING | Seal |
| 700429076000 | O-RING | Seal |
| 735252070000 | O-RING | Seal |
| 735252085001 | O-RING | Seal |
| 735252090000 | O-RING | Seal |
| 735252100000 | O-RING | Seal |
| 347646 | Sensor, Liquid Level | Sensor |
| 12V4000Gx3-08 | Spark plug | Spark plug |
| M128R | Starter | Starter |
| 59420300059 | THERMAL ACTUATOR | Thermostat |
Parts cataloged across all variants of this engine family — verify the exact part fits your specific variant and serial number before ordering.
Parts listed by aftermarket suppliers as fitting this engine — leads compiled from supplier catalogs; verify the exact part for your serial number.
Other equipment known to use this engine, via filter-application cross-reference — useful for sourcing parts even when your exact machine isn't listed elsewhere on this page.
The MTU 16V 4000 G23 engine has an oil capacity of 300.0 liters.
The MTU 16V 4000 G23 has a displacement of 76.3 liters with 20 cylinders.
The MTU 16V 4000 G23 powers 5 generator set(s), including MTU 16 V 4000 G23, MTU 16V4000 DS2250, MTU DP 2145 D5S FW, MTU DS 2285 D5S FW, Talles HMW-2080 T5.
A commonly reported issue on generators using the MTU 16V 4000 G23 is: LO P-Fuel (Common Rail pressure < reference value; DBR fuel limitation, start of injection readjusted towards late; suction restrictor of HP fuel block jamming or HP fuel control block wiring faulty.. Fix: Contact Service..