Mitsubishi S4Q2 Engine

The Mitsubishi S4Q2 is a 2.5 L 4-cylinder naturally aspirated engine rated at 1500 rpm, producing up to 32 kW. It powers generator sets from Pt. Berkat Manunggal Jaya, including the BMGS.020LSP5. It holds 5.5 L (1.5 gal) of oil and 8.1 L (2.1 gal) of coolant.

Also known as: Mitsubishi S4Q2

Part of the Mitsubishi S4Q2 engine family — 10 variants share parts & fitment.

2.505 L
Displacement
4
Cylinders
1500 rpm
Rated speed
32 kW
Gross power

Engine specifications

Oil capacity5.5 L
Coolant capacity8.1 L
Displacement2.505 L
Cylinders4
Aspirationnaturally aspirated
Rated speed1500 rpm
Gross power32 kW

Generator sets powered by this engine

1

This engine also powers 1 machine(s) on Power Equipment Info.

How to read your Mitsubishi engine serial & model number →

Service intervals

30
ItemActionHoursMonthsNotes
BatteryOther250 hr6 moService battery.
Engine mountsCheck250 hr6 moCheck tightness and vibration isolator condition
Engine oil and filterChange250 hr6 moMay extend to 375 hours with John Deere PLUS-50 oil and John Deere oil filter.
Fire extinguisherInspect250 hr1 moInspect at least every 250 hours or once a month
Fire extinguisherOther250 hr6 moService fire extinguisher.
PTO clutch adjustmentCheck250 hr6 mo
PTO clutch shaft bearingsLubricate250 hr6 mo
Starter batteryTest250 hr6 moService battery; check electrolyte and connections
Air intake hoses, connections and systemCheck500 hr12 mo
Air intake hoses, connections, and systemInspect500 hr12 mo
Automatic belt tensioner and belt wearCheck500 hr12 mo
Belt tension and manual tensionerCheck500 hrPOWERTECH engines with manual tensioner
Coolant solutionTest600 hr12 moAnalyze coolant; add SCAs as needed.
Cooling systemCheck500 hr12 mo
Cooling systemTest500 hr12 moPressure test cooling system.
Crankcase vent tubeClean500 hr12 mo
Engine oil and oil filterChange500 hr12 moFirst service — Then every 500 hours or at least once a year
Fuel filter elementReplace500 hr12 mo
PTO clutch internal levers and linkageLubricate500 hr12 mo
Automatic belt tensionerCheck1000 hr12 moPOWERTECH engines when equipped
Cooling systemOther2000 hr24 moFlush cooling system; COOL-GARD may extend to 3000 hours/36 months or 5000 hours/60 months with annual testing and SCA replenishment.
Crankshaft vibration damperCheck2000 hr24 mo6-cylinder engine only.
Engine valve clearanceAdjust2000 hrPOWERTECH engines
ThermostatsTest2000 hr24 mo
Valve clearanceAdjust2000 hr24 mo
Cooling systemDrain2500 hr36 moWith John Deere COOL-GARD; otherwise every 2000 hours/24 months
Crankshaft vibration damper (6-cylinder)Replace4500 hr60 moWhichever occurs first
Injection nozzlesReplace5000 hr
ThermostatReplace10000 hr
Air filter elementReplace12 moAfter 6 cleanings or once a year

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Service specifications

60
TypeItemValueUnitCondition
ClearanceAir cleaner neck to engine intake overlap38mm1.5 in
ClearanceBelt deflection twist check75-85degreesTwist belt in middle of 10-12 inch span
ClearanceExhaust valve clearance adjustment0.46mmengine cold; 0.018 in
ClearanceExhaust valve clearance checking0.41—0.48mmengine cold; rocker arm-to-valve tip
ClearanceIntake valve clearance adjustment0.36mmengine cold; 0.014 in
ClearanceIntake valve clearance checking0.31—0.38mmengine cold; rocker arm-to-valve tip
Other12 V heavy duty starter cold cranking amps800CCAAt -18 C
Other12 V standard duty starter cold cranking amps640CCAAt -18 C
Other24 V standard duty starter cold cranking amps570CCAAt -18 C
OtherAuxiliary gear drive continuous operation limit30kWAt 2500 rpm
OtherAuxiliary gear drive intermittent operation limit37kWAt 2500 rpm
OtherCoolant drain interval with John Deere COOL-GARD5000 hours or 5 yearshours/yearsIf coolant tested annually and additives replenished
OtherCoolant drain interval without COOL-GARD2000 hours or 2 yearshours/yearsOther coolant
OtherCoolant drain interval, factory fill3000 hours or 3 yearshours/yearsFirst drain
OtherCoolant test interval600 hours or 12 monthshours/monthsOr less; whenever excessive coolant is lost
OtherTachometer binary code1011001130 pulses per revolution
PressureAir restriction indicator vacuum625mm H2OReplace primary element at this restriction
PressureCooling system test70kPa0.7 bar; 10 psi
PressureEngine oil pressure at full load345 ± 103kPaAt normal operating temperature, 115 C sump
PressureMaximum air intake restriction6.25kPaEquivalent to 0.06 bar, 1.0 psi, 25 in. H2O
PressureMinimum oil pressure at 850 rpm105kPa850 rpm
PressureMinimum oil pressure at rated speed275kPaRated speed
PressureNew 8-rib Poly-Vee belt tension, Bosch and Magneton alternator535-715NNew belt
PressureNew 8-rib Poly-Vee belt tension, old Magneton alternator470-650NNew belt, option code 3101
PressurePTO clutch engagement force267-311NMeasured at handle grip with spring scale
PressureRadiator cap test70kPa0.7 bar; 10 psi; hold pressure 10 seconds
PressureUsed 8-rib Poly-Vee belt tension400-580NUsed belt
ResistanceInsulation minimum1megohmstator
ResistanceInsulation minimum100000ohmother windings
ResistancePMG stator phase/phase resistance0.7ohm20°C
SpeedSlow idle speed850rpmFactory setting
TemperatureAutomatic shutdown coolant temperatureapproximately 115CIf equipped with safety controls
TemperatureBearing overheating80°Con bearing retainers with or without abnormal noise
TemperatureBearing temperature rise60°Cmaximum above ambient
TemperatureCoolant freeze protection at 40% ethylene glycol-24C40% ethylene glycol
TemperatureCoolant freeze protection at 50% ethylene glycol-37C50% ethylene glycol
TemperatureCoolant freeze protection at 60% ethylene glycol-52C60% ethylene glycol
TemperatureCoolant temperature for load reduction112CReduce load above this temperature
TemperatureNormal engine coolant operating temperature range82-94CNormal operation
TemperatureNormal engine coolant temperature82—94°C180—202°F
TemperatureThermostat initial opening69—72°C71°C (160°F) rating; full open nominal 84°C (182°F)
TemperatureThermostat initial opening80—84°C82°C (180°F) rating; full open nominal 94°C (202°F)
Torque43.2 disc/shaft screw110NmM12
Torque43.2 tie rod57NmM12
Torque44.2 disc/shaft screw180NmM14
Torque44.2 tie rod90NmM14
Torque44.2 turbine screw5NmM6
TorqueAir cleaner neck clamp6.8N•m60 lb-in
TorqueBelt tensioner spring tension18-22N•mautomatic tensioner; 13-16 lb-ft
TorqueCover cap screws without thermostats47N•m35 lb-ft
TorqueCover screws5NmM6
TorqueDiode bridge/RP5N.mM6
TorqueDiode nut4N.mM5
TorqueEarth screw26NmM8
TorqueField screw10N.mM6
TorqueField terminal block screw4N.mM4
TorqueFuel injection nozzle connection27N•m20 lb-ft
TorqueFuel return line connector27N•m20 lb-ft
TorqueGrille screws5NmM6
TorqueRocker arm adjusting screw jam nut27N•mengine cold; 20 lb-ft

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Recommended fluids

FluidGradeStandardAmbientCapacityNotes
CoolantJohn Deere COOL-GARD Prediluted Coolant or COOL-GARD Concentrate 40-60% with quality waterASTM D5345 prediluted or ASTM D4985 concentrate; low silicate ethylene glycol50% ethylene glycol gives freeze protection to -37 C; do not use automotive-type coolant
CoolantJohn Deere COOLANT CONDITIONER supplemental coolant additiveReplenish supplemental coolant additives as required; do not over-add
Coolantlow silicate, ethylene-glycol base antifreezeJohn Deere COOL-GARDUse TY16004 or TY16005 Liquid Coolant Conditioner; conditioner does not protect cooling system from freezing.
Engine oilJohn Deere ENGINE BREAK-IN OILAPI CE or ACEA E1 if John Deere break-in oil unavailableFirst 100 hours of new or rebuilt engine; part TY22041
Engine oilJohn Deere PLUS-50 oilOil change interval may be extended by 50 percent to 375 hours with John Deere PLUS-50 oil and John Deere oil filter.
Engine oilJohn Deere PLUS-50 preferred; John Deere TORQ-GARD SUPREME recommendedAPI CH-4, CG-4, CF-4; ACEA E3, E2Use seasonal viscosity grade based on expected air temperature range between oil changes
FuelDiesel fuel; Grade No. 1-D below 5 CEN 590 or ASTM D975; cetane minimum 40; sulfur maximum 0.5%; lubricity BOCLE minimum 3100 gDo not use diesel fuel with sulfur greater than 1.0%; do not mix used oil with fuel
FueldieselUse proper type fuel for operating conditions.
GreaseJohn Deere Multipurpose LubricantFor PTO clutch linkage pivot points and release lever shaft fittings.
GreaseJohn Deere SD POLYUREA GREASE preferred; HD MOLY, HD LITHIUM COMPLEX, HD WATER RESISTANT, GREASE-GARD also recommendedNLGI Performance Classification GC-LBConsult supplier before mixing different grease thickeners
GreasePT507 Multi-Purpose GreaseLubricate new thermostat O-ring.
OtherAR41785Engine Storage Kit.
OtherAR41937Nucle Oil for circulating through injection system during storage/ cranking.
OtherTY15161Cooling System Sealer may be added to radiator to stop leaks; do not use other stop-leak additives.
OtherTY15979John Deere Heavy Duty Cooling System Cleaner, or equivalent Fleetguard RESTORE/RESTORE PLUS.
OtherTY16004 or TY16005Liquid Coolant Conditioner; recharge at 500 hours or 12 months.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Fault codes

80
CodeNameMeaningSeverityAction
00-1Generator set emergency stop
01-1External emergency stop
02-1Engine oil pressure
03-1Engine water temperature
04-0Daily fuel tank level low alarm
04-1Daily fuel tank level low fault
05-1Radiator water level low
06-0Alternator overload or short-circuit alarm
06-1Alternator overload or short-circuit fault
07-1Engine overspeed
08-0Min. battery voltage alarm
08-1Min. battery voltage fault
09-0Max. battery voltage alarm
09-1Max. battery voltage fault
10-0Lithium battery absent
11-1Generator set no start
12-0Min. alternator voltage alarm
12-1Min. alternator voltage fault
13-0Max. alternator voltage alarm
13-1Max. alternator voltage fault
14-0Min. alternator frequency alarm
14-1Min. alternator frequency fault
15-0Max. alternator frequency alarm
15-1Max. alternator frequency fault
16-1Option 3 module CAN bus
17-1Option 4 module CAN bus
18-1Option 5 module CAN bus
19-1Option 6 module CAN bus
22-1Hardware watchdog
25-0Normal contactor open (system side)
26-0Emergency contactor open (generating set side)
27-1Oil temperature
28-1Oil level low
29-0No water preheating alarm
29-1No water preheating fault
30-0Differential trigger alarm
30-1Differential trigger fault
31-0Permanent insulation monitor trigger alarm
31-1Permanent insulation monitor trigger fault
32-1Differential relay connection
33-1Permanent insulation monitor connection
34-0Battery charger fault alarm
34-1Battery charger fault shutdown
35-1Air cooler trip
36-1Air cooler low level
37-0Fuel pump 1 trip alarm
37-1Fuel pump 1 trip fault
38-0Retention tank alarm
38-1Retention tank fault
39-0Fuel tank low level alarm
39-1Fuel tank low level fault
40-1Water flow
41-1Fire detection
42-1Oil leak
43-1Fuel leak
44-1Air cooler compartment door open
45-1MCPS door open
46-0Main circuit breaker open alarm
46-1Main circuit breaker open fault
47-0Overload
48-1MTU engine oil pressure
49-1MTU engine HV water temperature
50-1MTU engine overspeed
51-1MTU engine general fault
52-0MTU engine general alarm
53-1QST30 engine overspeed
54-1QST30 engine general fault
55-0QST30 engine general alarm
56-0Engine oil high level alarm
57-1Engine oil high level fault
58-0Startup battery min. voltage
59-0Startup battery charger
60-1MX coil
61-1Damping valve
62-0Starter air pressure
63-0Magneto-thermal relay
64-0Engine oil pressure alarm
65-0Engine water temperature alarm
66-0Engine oil temperature alarm
67-0Fuel low level (combined in option No. 16)

Showing the first 80 of 93 codes.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Procedures

12
Check and Adjust Valve Clearance adjustment

⚠ Valve clearance must be checked and adjusted with engine cold.

Tools: JDE83 or JDG820 Flywheel Turning Tool, JDE81-4 Timing Pin, Feeler gauge

  1. Disconnect negative battery terminal.
  2. Remove rocker arm cover and crankcase ventilator tube.
  3. Remove timing hole plugs; rotate engine to No. 1 TDC compression.
  4. Insert JDE81-4 timing pin in flywheel.
  5. Check intake and exhaust valve clearances with engine cold.
  6. Loosen jam nut and adjust screw until feeler gauge drags slightly.
  7. Hold screw, tighten jam nut to 27 N•m (20 lb-ft), recheck clearance.
  8. Repeat for remaining valves per 4- or 6-cylinder sequence.
Manual belt tensioner adjustment adjustment

⚠ Do not pry against alternator rear frame.

Tools: JDG1341 belt tension gauge

  1. Install JDG1341 belt tension gauge halfway between pulleys.
  2. Loosen cap screws B and C.
  3. Slide alternator or tensioner bracket by hand to remove slack.
  4. Pry outward on alternator front frame or tensioner bracket to stretch belt.
  5. Stretch until specified tension is achieved.
  6. Tighten cap screws B and C.
  7. Run engine ten minutes and recheck used belt tension.
Pressure Testing Cooling System diagnostic

⚠ Explosive release of fluids from pressurized cooling system can cause serious burns.

Tools: D05104ST Tester

  1. Remove radiator cap and attach to D05104ST tester.
  2. Pressurize cap to 70 kPa (0.7 bar) (10 psi).
  3. Gauge should hold pressure for 10 seconds.
  4. Retest cap turned 180 degrees to verify.
  5. Connect gauge and adapter to radiator filler neck.
  6. Pressurize system to 70 kPa and check for leaks.
Testing Thermostats Opening Temperature diagnostic

⚠ Do not let thermostat or thermometer rest against container side or bottom.

Tools: Thermometer, Container

  1. Remove thermostat(s) and inspect for corrosion or damage.
  2. Suspend thermostat and thermometer in water.
  3. Stir water as it heats and observe opening action.
  4. Compare opening temperatures with specification chart.
  5. Remove thermostat and observe smooth closing as it cools.
  6. Replace defective thermostat; replace dual thermostats as matched set.
Hitching trailer installation

⚠ Towing with a non-matching device can cause serious accidents.

  1. Lock wheels to stop trailer moving.
  2. Lift rear trailer supports and lock them.
  3. Release parking brake.
  4. Release draw bar arm locking levers and adjust ring to vehicle hook height.
  5. Hitch trailer and remove wheel locks.
  6. Lift front wheel fully using its handle.
  7. Connect trailer electrical circuit to tow vehicle.
  8. Hook handbrake safety wire onto tow vehicle hook.
Unloading with fork lift truck installation

Tools: fork lift truck with arms longer than frame width

  1. Position fork lift arms under frame cross beams only.
  2. Lift and handle equipment carefully.
  3. Set down generating set in unloading position.
Unloading with slings installation

⚠ Never carry out work on a generating set suspended on a lifting device only.

Tools: crane, slings, lifting beam, safety hook, shackles

  1. Attach lifting slings to the set's designated lifting rings.
  2. Hang slings carefully and check they are correctly attached.
  3. Check equipment is solid before lifting.
  4. Lift the generating set carefully.
  5. Direct and stabilise the set toward the chosen position.
  6. Set down carefully while continuing to position it.
  7. Release slings, then detach and remove lifting rings.
Battery test sequence maintenance

⚠ Keep sparks and flames away from battery.

Tools: Midtronics, Wega, or similar battery tester, hydrometer

  1. Visually inspect tray, terminals, and electrolyte level.
  2. If electrolyte below prescribed level, add water and charge 4-5 hours.
  3. Check electrolyte density; above 1.22 kg/l proceed to electrical test.
  4. If density is below 1.22 kg/l or cell variation exceeds 50 g/l, recharge or replace.
  5. Use Midtronics, Wega, or similar tester for quick electrical performance test.
  6. Replace battery if tester gives negative result.
Bleeding the Fuel System maintenance

⚠ Escaping fluid under pressure can penetrate skin.

  1. Loosen air bleed vent screw two full turns on filter base.
  2. Operate supply pump primer lever until fuel is free of bubbles.
  3. Tighten bleed plug; continue priming until resistance is felt.
  4. Push hand primer inward toward engine.
  5. Start engine and check for leaks.
Changing engine oil and replacing oil filter maintenance

⚠ Do not overtighten filter element.

Tools: filter wrench

  1. Run engine about 5 minutes to warm oil; shut off.
  2. Remove oil pan drain plug and drain crankcase oil while warm.
  3. Remove and discard oil filter element using a filter wrench.
  4. Clean filter mounting pad and remove old packing.
  5. Oil new packing and install new filter; hand tighten 3/4-1-1/4 turn after contact.
  6. Install drain plug with new seal.
  7. Fill crankcase with correct oil; do not overfill.
  8. Start engine, check leaks, stop, and check oil level after 10 minutes.
Checking Tensioner Spring Tension maintenance

Tools: Breaker bar, Socket, Torque wrench

  1. Release belt tension using breaker bar and socket.
  2. Remove belt from pulleys and release tension arm.
  3. Mark swing arm (A) and mounting base 21 mm away (B).
  4. Rotate swing arm with torque wrench until marks align.
  5. Record torque and compare with specification.
  6. Replace tensioner assembly as required.
Checking air intake system maintenance

⚠ The air intake system must not leak; leaks may cause internal engine damage.

  1. Inspect all intake hoses for cracks; replace as necessary.
  2. Check clamps connecting air cleaner, engine, and turbocharger; tighten as necessary.
  3. Inspect rubber dust unloader valve for cracks or plugging.
  4. Test air restriction indicator for proper operation.
  5. Remove and inspect primary air cleaner element; service as necessary.
  6. Replace air cleaner elements at 600 hours or 12 months if no indicator.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Voltage reconnection

VoltagePhaseConnectionLeadsNotes
110-1201GT1-T12Winding 6/7/8. R 230 sensing 0=>T8 / 110 V=>T11; R 438 sensing 0=>T3 / 110 V=>T2.
190-208 (60 Hz) / 190-240 (50 Hz)3AT1-T12Winding 6/7/8. R 230 sensing 0=>T8 / 110 V=>T11; R 438 sensing 0=>T3 / 220 V=>T2.
220-2401MT1-T12Winding 6/7/8. R 230 sensing 0=>T8 / 110 V=>T11; R 438 sensing 0=>T3 / 220 V=>T2.
220-2401 or 3FFT1-T12Winding 6/7/8. R 230 sensing 0=>T1 / 110 V=>T4; R 438 sensing 0=>T10 / 220 V=>T1.
220/230/240 L-L; 110/115/120 L-M1M or M1 dedicated 4-wireT2-T3, T2-T3, T1-T4Single-phase 4-wire; parallel connection not possible with LSA 44.2.
380-415 (50 Hz) / 380-480 (60 Hz)3ART1-T12Winding 6/7/8. R 230 sensing 0=>T8 / 110 V=>T11; R 438 sensing 0=>T3 / 380 V=>T2.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Parts cataloged across the Mitsubishi S4Q2 family

25
Part #DescriptionCategory
30801032101NEDusty air filter assemblyAir filter
330170365BeltBelt
330910098Coolant GENCOOL (20L)Fluid
330910115Oil GENLUB TDX 20LFluid
330170614Water pump gasketGasket
330170777Exhaust gasketGasket
330170780GasketGasket
330170844GasketGasket
330171211GasketGasket
330171571GasketGasket
330171575GasketGasket
330171484DuritHose
330171692DuritHose
330171942Lower DuritHose
330171943Upper radiator DuritHose
330170272Oil filterOil filter
AEHQ5682-03304C CR Mini Hydraulic ExcavatorService part / kit
AEHQ5683305C CR Mini Hydraulic ExcavatorService part / kit
AEHQ5683-03305C CR Mini Hydraulic ExcavatorService part / kit
AEHQ6016904H Compact Wheel LoaderService part / kit
31810015101NKOil drain pump assemblyPump
330170513Water pumpPump
330170581Oil pumpPump
31101077801NKCoolant temp. and oil pressure sender assemblySensor
330170377ThermostatThermostat

Parts cataloged across all variants of this engine family — verify the exact part fits your specific variant and serial number before ordering.

Aftermarket parts that fit this engine

59
4Pcs FridayParts $7.88 SinoCMP $25.90 32A66-03102 FridayParts $34.00 MM435-94101 FridayParts $56.99 49131-02710 FridayParts $228.98 32C65-04010 FridayParts $1259.99 32C65-04011 FridayParts $1259.99 32A36-05011 FridayParts $85.00 32C65-04040 FridayParts $1838.00 092000-4550 FridayParts $1838.00 092000-4171 FridayParts $1500.00 32C65-04030 FridayParts $1500.00 MM514045 FridayParts $89.99 32C47-05011 FridayParts $1172.90 32A66-20601 FridayParts $252.88 32C65-10320 FridayParts $889.76 32C65-00320 FridayParts $889.76 0.5MM FridayParts $27.25 30617-72011 FridayParts $97.60 MT40006823 FridayParts $58.00 32C01-12100 FridayParts $58.00 40006823 FridayParts $58.00 30604-21401 FridayParts $79.99 YI62SD FridayParts $79.99 Y262SD FridayParts $79.99 Z263SD FridayParts $79.99 Z2DT62SD FridayParts $79.99 Y362SD FridayParts $79.99 Y3DT61SD FridayParts $79.99 32C61-06000 eBay FridayParts $90.01 32C01-01040 FridayParts $690.00 32C19-05100 FridayParts $131.50 32C19-00014 FridayParts $131.50 272-0445 FridayParts $131.50 91402-01200 FridayParts $16.99 91801-08600 FridayParts $16.99 34461-09050 eBay FridayParts $35.00 32A05-13100 FridayParts $84.00 103-9273 FridayParts $84.00 1584795 KuduParts $216.00 FridayParts $225.99 CA1584795 KuduParts $216.00 1639997 KuduParts $216.00 FridayParts $225.99 CA1639997 KuduParts $216.00 32c65 FP-XP-0013171 32C45-00023 FridayParts $54.00 32c45 FP-XP-0011139 266-6942 FridayParts $2301.02 FP-XP-0045526 DP150 FridayParts $25.99 FP-XP-0009930 TC48 FridayParts $47.99 104741-8081 FridayParts $739.00 32C6510310 FridayParts $739.00 FP-XP-0013315 280-3768 SinoCMP $469.00 FridayParts $695.00 305C FridayParts $24.00 SinoCMP $119.00 TD03 FridayParts $199.80 SinoCMP $279.00 49131-05512 SinoCMP $349.00

Parts listed by aftermarket suppliers as fitting this engine — leads compiled from supplier catalogs; verify the exact part for your serial number.

Also used in

8
  • Caterpillar 304C — Excavator Tracked
  • Caterpillar 305.5D — Excavator Compact
  • Caterpillar 305C — Excavator Tracked
  • Caterpillar 904B — Loader Wheeled
  • Caterpillar 904H — Loader Wheeled
  • Orenstein & Koppel 1.48 — Construction Equipment
  • Terex HR18 — Excavator Compact
  • Westerbeke 44B FOUR — Engine

Other equipment known to use this engine, via filter-application cross-reference — useful for sourcing parts even when your exact machine isn't listed elsewhere on this page.

Common questions

What is the oil capacity of the Mitsubishi S4Q2?

The Mitsubishi S4Q2 engine has an oil capacity of 5.5 liters.

What is the displacement of the Mitsubishi S4Q2?

The Mitsubishi S4Q2 has a displacement of 2.505 liters with 4 cylinders.

Which generators use the Mitsubishi S4Q2 engine?

The Mitsubishi S4Q2 powers 1 generator set(s), including Pt. Berkat Manunggal Jaya BMGS.020LSP5.