The Kohler Command PRO OHV CH1000 is a 999 L engine rated at 3600 rpm. It powers generator sets from Kohler, including the 20RES.
Also known as: KOHLER Command PRO OHV CH1000
| Displacement | 999.0 L |
|---|---|
| Rated speed | 3600 rpm |
Compiled from service & troubleshooting documentation across every generator set that uses the Kohler Command PRO OHV CH1000.
| Item | Action | Hours | Months | Notes |
|---|---|---|---|---|
| Oil level | Check | 8 hr | Before each use or every 8 hours for extended operation | |
| Engine oil | Change | 100 hr | 12 mo | 14 kW models: 100 hours; 20 kW models: 150 hours |
| Oil (14 kW) | Change | 100 hr | 12 mo | |
| Air cleaner | Replace | 150 hr | 300 hours shown; service more frequently under dusty/dirty conditions | |
| Air cleaner service | Clean | 150 hr | 12 mo | 14 kW: 150/300 hours; 20 kW: 150/300 hours yearly |
| Oil (20 kW) | Change | 150 hr | 12 mo | |
| Oil filter (20 kW) | Replace | 150 hr | 12 mo | |
| Oil filter | Replace | 200 hr | 12 mo | 14 kW models: 200 hours; 20 kW models: 150 hours |
| Oil filter (14 kW) | Replace | 200 hr | 12 mo | |
| Generator brushes and collector ring | Replace | 300 hr | 12 mo | Authorized distributor only |
| Spark plugs | Replace | 300 hr | 12 mo | 150-300 hours shown |
| Crankcase breather hose | Inspect | 500 hr | 12 mo | Yearly or 500 hours |
| Air ducts and louvers | Clean | 12 mo | ||
| Battery | Check | 1 mo | Check charger operation, charge rate | |
| Fuel flexible lines and connections | Inspect | 3 mo | Quarterly; replace as necessary | |
| Fuel piping | Inspect | 12 mo | Yearly | |
| Main tank fuel supply level | Check | 0 mo | Weekly |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Type | Item | Value | Unit | Condition |
|---|---|---|---|---|
| Gap | Spark plug | 0.03 | in. | |
| Gap | Spark plug | 0.76 | mm | |
| Gap | Spark plug gap | 0.51 | mm (0.02 in.) | |
| Gap | Spark plug gap | 0.7--0.8 | mm (0.028--0.030 in.) | |
| Gap | Spark plug gap | 0.76 | mm (0.03 in.) | |
| Gap | Spark plug gap | 0.8--0.9 | mm (0.03--0.04 in.) | |
| Gap | Spark plug gap | 0.89 | mm (0.035 in.) | |
| Gap | Spark plug gap | 0.9--1.0 | mm (0.036--0.04 in.) | |
| Other | Battery wrap length | 1067 (42) | mm (in.) | |
| Other | Battery wrap length | 864 (34) | mm (in.) | |
| Other | Heater wrap rating | 50 | Watts | |
| Other | Heater wrap rating | 65 | Watts | |
| Other | Plug cord length | 75 (3) | mm (in.) | |
| Other | Power cord length | 1677 (66) | mm (in.) | |
| Other | Power cord length | 1830 (72) | mm (in.) | |
| Other | Power cord length | 483 (19) | mm (in.) | |
| Temperature | Carburetor heater thermostat OFF | 16 ± 3 | C (60 ± 5F) | |
| Temperature | Carburetor heater thermostat ON | 4 ± 4 | C (40 ± 7F) | |
| Temperature | Exhaust temperature | 260 | C | at rated kW |
| Temperature | Thermostat OFF | 16 ± 3 | °C | Thermostat OFF (60 ± 5°F) |
| Temperature | Thermostat ON | 4 ± 4 | °C | Thermostat ON (40 ± 7°F) |
| Temperature | Thermostat off temperature | 27 | C (80 F) | |
| Temperature | Thermostat on temperature | 16 | C (60 F) | |
| Torque | Spark plug | 18 | ft. lb. | |
| Torque | Spark plug | 22 | ft. lb. | |
| Torque | Spark plug | 24.4 | Nm | |
| Torque | Spark plug | 29.8 | Nm | |
| Torque | Spark plug torque | 15 | Nm (11 ft. lb.) | |
| Torque | Spark plug torque | 18 | Nm (13.3 ft. lb.) | |
| Torque | Spark plug torque | 24.4--29.8 | Nm (18--22 ft. lb.) | |
| Torque | Spark plug torque | 25 | Nm (18 ft. lb.) | |
| Voltage | Voltage regulation | 1.0 | % | no-load to full-load RMS |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Fluid | Grade | Standard | Ambient | Capacity | Notes |
|---|---|---|---|---|---|
| Engine oil | 5W-30 or 10W-30 | API Service Class SG, SH, or SJ synthetic | 1.8 L | 14 kW models; synthetic oil oxidizes and thickens less | |
| Fuel | Natural gas or propane | Certified for emergency standby use only | |||
| Fuel | Natural Gas or LPG | Natural gas: 90% min methane. LPG: 85% min propane. Fuel supply pressure: Natural gas 0.9-2.7 kPa, LPG 1.7-2.7 kPa | |||
| Fuel | Natural gas or LPG | Generator set is certified for emergency standby operation only |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Code | Name | Meaning | Severity | Action |
|---|---|---|---|---|
| AC Sens Loss | AC Sensing Lost | In Auto mode, generator output AC sensing is lost. Detection begins 10 seconds after crank disconnect. | Warning | Contact authorized distributor/dealer for service |
| ATS ComError | ATS Communication Error | Warning is displayed if ATS interface connection is lost | Warning | Check communication wiring between transfer switch interface board and generator set |
| ATS PhaseRot | ATS Phase Rotation Mismatch | Transfer switch phase rotation does not match; ATS will not transfer | Warning | Correct the ATS connection per ATS Installation manual and labels |
| Accy PwrOver | Accessory Power Overload | An over current fault (short circuit) on the accessory controller power output | Warning | Contact authorized distributor/dealer for service |
| Battery CrLo | Battery Crank Low | Engine starting battery voltage falls below 11 VDC for more than 10 seconds | Warning | Clears when battery voltage returns to acceptable level |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Tools: digital voltmeter, personal computer, SiteTech software
Tools: digital voltmeter
Tools: clamp-on DC current probe or DC current meter
⚠ Accidental starting can cause severe injury or death; disconnect battery cables before working on the generator set, negative lead first.
⚠ Hazardous voltage will cause severe injury or death; disconnect all power sources before opening the enclosure.
⚠ Hot surfaces: disconnect power to the heater and allow it to cool before servicing.
⚠ Accidental starting can cause severe injury or death; disconnect battery cables before working on the generator set, negative lead first.
⚠ Hazardous voltage will cause severe injury or death; disconnect all power sources before opening the enclosure.
⚠ Hot surfaces: install the heater before connecting it to power; disconnect power and allow it to cool before servicing.
⚠ Disconnect battery cables before working on generator set; remove negative lead first.
⚠ Disconnect all power sources before opening enclosure.
⚠ Install heater before connecting power; allow to cool before servicing.
⚠ Disconnect battery cables before working on generator set; remove negative lead first.
⚠ Disconnect all power sources before opening enclosure.
⚠ Install heater before connecting power; allow to cool before servicing.
⚠ Do not wash paper element or clean with pressurized air
⚠ Do not wash paper element or use pressurized air
⚠ Do not load RDC2.4 firmware onto a red- or green-board controller
Tools: personal computer, USB cable, SiteTech software
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Voltage | Phase | Connection | Leads | Notes |
|---|---|---|---|---|
| 100/200 | 1 | Single | ||
| 100/200 | 3 | Delta | ||
| 110/220 | 1 | Single | ||
| 110/220 | 3 | Delta | ||
| 115/230 | 1 | Single | ||
| 120 | 1 | Single | Genset System Voltage/Frequency/Phase table for controller setup | |
| 120/208 | 3 | Wye | ||
| 120/240 | 1 | Single | ||
| 120/240 | 1 | Single phase | 4 | 1.0 power factor |
| 120/240 | 3 | Delta | ||
| 127/220 | 3 | Wye | ||
| 220 | 1 | Single | ||
| 220/380 | 3 | Wye | ||
| 230 | 1 | Single | ||
| 230/400 | 3 | Wye | ||
| 240 | 1 | Single | ||
| 240/416 | 3 | Wye | ||
| 277/480 | 3 | Wye |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
The Kohler Command PRO OHV CH1000 has a displacement of 999.0 liters.
The Kohler Command PRO OHV CH1000 powers 1 generator set(s), including Kohler 20RES.
A commonly reported issue on generators using the Kohler Command PRO OHV CH1000 is: The generator set does not crank.. Cause: Battery weak or dead.. Fix: Recharge or replace the battery..