HomeEnginesIsuzu 4LE1NYGV-03G

Isuzu 4LE1NYGV-03G Engine

The Isuzu 4LE1NYGV-03G is a 2.2 L 4-cylinder n/a engine rated at 1800 rpm, producing up to 31.5 kW. It powers generator sets from Isuzu and Magnum, including the MLG20ICAN. It holds 3.5 L (0.9 gal) of oil and 4.5 L (1.2 gal) of coolant.

Also known as: Isuzu 4LE1NYGV-03G

Part of the Isuzu 4LE1NYGV engine family — 4 variants share parts & fitment.

2.2 L
Displacement
4
Cylinders
1800 rpm
Rated speed
31 kW
Gross power

Engine specifications

Oil capacity3.5 L
Coolant capacity4.5 L
Displacement2.2 L
Cylinders4
AspirationN/A
Rated speed1800 rpm
Gross power31 kW

Generator sets powered by this engine

2

Shared across brands: Isuzu, Magnum

Troubleshooting

6

Symptoms & remedies

SymptomRemedy
Mast light is too hotAllow light to cool 10-15 minutes before restarting.
Faulty bulb connectionCheck that the bulb is tight in the socket.
Bulb brokenCheck for broken arc tube or outer bulb jacket, broken or loose components in bulb envelope or blackening/deposits inside tube.
Mast lights off but ballast indicators on control panel are on1. Mast light is too hot. Allow light to cool 10-15 minutes before restarting. 2. Faulty bulb connection. Check that the bulb is tight in the socket. 3. Bulb broken. Check for broken arc tube or outer bulb jacket, broken or loose components in bulb envelope or blackening/deposits inside tube. 4. Check the connections inside the mast junction box and each mast light housing/socket. 5. Check the mast electrical cord for damage and check the cord connections inside the control box.
Mast lights off and ballast indicators on control panel are off1. Check the connections inside the control box and inside each ballast box. 2. Generator output incorrect. Check the incoming voltage to the ballast by checking the available voltage on the duplex receptacle. Incoming voltage should be 120V +/- 5V. If voltage is incorrect, the engine speed may need to be adjusted or generator may require service. 3. Low transformer output. The voltage from the transformer should read approximately 400 VAC as the light “strikes” (induces an arc), then drop and slowly rise back up to stabilize at 240-260 VAC. On quick disconnect models, measure across the junction box terminals when the light is unplugged. On hard wired models, remove the mast junction box cover and insert the wire probes into the connector blocks for the light and ground. If proper voltage is not achieved, perform capacitor check to determine if the capacitor or coil needs to be replaced.
Mast lights on but the light output is low1. Fixture or lens are dirty. Clean reflective surface inside fixture and both inside and outside surface of glass lens. Use mild soap and water to clean lens. Other chemicals may have an adverse effect on the glass. 2. Bulb worn due to normal use. Replace bulb. 3. Check the mast coil cord, mast junction box and mast light connections. 4. Generator output incorrect. Check the incoming voltage to the ballast. Incoming voltage should be 120V +/- 5V. If voltage is incorrect, engine speed may need to be adjusted or generator may require service. 5. Low transformer output. The voltage from the transformer should read approximately 400 VAC as the light “strikes” (induces an arc), then drop and slowly rise back up to stabilize at 240-260 VAC. On quick disconnect models, measure across the junction box terminals when the light is unplugged. On hard wired models, remove the mast junction box cover and insert the wire probes into the connector blocks for the light and ground. If proper voltage is not achieved, perform capacitor check to determine if the capacitor or coil needs to be replaced.

Fault codes and symptom→remedy steps extracted from this engine’s service/owner documentation; verify against the official manual before servicing.

Common problems

6
  • Mast lights on but the light output is low
    Fix: 1. Fixture or lens are dirty. Clean reflective surface inside fixture and both inside and outside surface of glass lens. Use mild soap and water to clean lens. Other chemicals may have an adverse effect on the glass. 2. Bulb worn due to normal use. Replace bulb. 3. Check the mast coil cord, mast junction box and mast light connections. 4. Generator output incorrect. Check the incoming voltage to the ballast. Incoming voltage should be 120V +/- 5V. If voltage is incorrect, engine speed may need to be adjusted or generator may require service. 5. Low transformer output. The voltage from the transformer should read approximately 400 VAC as the light “strikes” (induces an arc), then drop and slowly rise back up to stabilize at 240-260 VAC. On quick disconnect models, measure across the junction box terminals when the light is unplugged. On hard wired models, remove the mast junction box cover and insert the wire probes into the connector blocks for the light and ground. If proper voltage is not achieved, perform capacitor check to determine if the capacitor or coil needs to be replaced.
  • Mast lights off but ballast indicators on control panel are on
    Fix: 1. Mast light is too hot. Allow light to cool 10-15 minutes before restarting. 2. Faulty bulb connection. Check that the bulb is tight in the socket. 3. Bulb broken. Check for broken arc tube or outer bulb jacket, broken or loose components in bulb envelope or blackening/deposits inside tube. 4. Check the connections inside the mast junction box and each mast light housing/socket. 5. Check the mast electrical cord for damage and check the cord connections inside the control box.
  • Mast lights off and ballast indicators on control panel are off
    Fix: 1. Check the connections inside the control box and inside each ballast box. 2. Generator output incorrect. Check the incoming voltage to the ballast by checking the available voltage on the duplex receptacle. Incoming voltage should be 120V +/- 5V. If voltage is incorrect, the engine speed may need to be adjusted or generator may require service. 3. Low transformer output. The voltage from the transformer should read approximately 400 VAC as the light “strikes” (induces an arc), then drop and slowly rise back up to stabilize at 240-260 VAC. On quick disconnect models, measure across the junction box terminals when the light is unplugged. On hard wired models, remove the mast junction box cover and insert the wire probes into the connector blocks for the light and ground. If proper voltage is not achieved, perform capacitor check to determine if the capacitor or coil needs to be replaced.
  • Mast light is too hot
    Fix: Allow light to cool 10-15 minutes before restarting.
  • Faulty bulb connection
    Fix: Check that the bulb is tight in the socket.
  • Bulb broken
    Fix: Check for broken arc tube or outer bulb jacket, broken or loose components in bulb envelope or blackening/deposits inside tube.

Compiled from service & troubleshooting documentation across every generator set that uses the Isuzu 4LE1NYGV-03G.

Parts cataloged across the Isuzu 4LE1NYGV family

36
Part #DescriptionCategory
12969Condenser (magneto)air_filter
12973Element, air filterair_filter
100AAlternatoralternator
26049Alternator, Isuzualternator
22258Belt, fanbelt
15006Cable, .188 in. x 27 ft. w/ball swedgecable
PE4024HF285Engine Model PE4024HF285engine
15331Fuel filter elementfuel_filter
13378Gasket, siliconegasket
285PSL5260Generator Model 285PSL5260generator
15612Cable, 16-7 cold mast drapehose
50018Hose - .312 ID 50 PSIhose
15183Filter, oil - Isuzuoil_filter
01203Combination Light Tower Generator & Water Trailerother_service
12142Decal, groundother_service
13370Assembly, tetherother_service
13660Radiator, 20kW wideother_service
14262Sheave, 3 in.other_service
15002Clamp, cable - .188other_service
15003Thimble, cableother_service
16600Winch, manualother_service
19258FAN, 15.75 INother_service
1NYGV-03Gother_service
22419BBracket, overflow jug .5 gal-blackother_service
24942Decal, Patented 7,642,665,B2other_service
26286Decal, Hood Serviceother_service
26386Decal, pinch pointother_service
26387Decal Set, Rear Hood Latchother_service
30093GSC Alarm Statusother_service
30175Decal, UN31A Tank Caution (Optional)other_service
34275Decal, Caution - 120 & 240 Outlets: 600V (MMG100CAN6 Only)other_service
34425Decal, Terminal Connections - 600Vother_service
MIT4150240 VAC 50 Amp Twistlock Outletsother_service
MIT4200240 VAC 30 Amp Twistlock Outletsother_service
12398Receptacle Panel (2x5-20R, 2xL6-30R, 2x50A)receptacle_panel
34424Decal Set, Voltage Selector Switch (x2)voltage_selector_switch_decal_set

Parts cataloged across all variants of this engine family — verify the exact part fits your specific variant and serial number before ordering.

Also used in

4
  • Hitachi EX40U — Excavator Compact
  • Hitachi EX50U — Excavator Compact
  • Hitachi EX55UR-3 — Excavator Compact
  • Hitachi EX58MU — Excavator Compact

Other equipment known to use this engine, via filter-application cross-reference — useful for sourcing parts even when your exact machine isn't listed elsewhere on this page.

Common questions

What is the oil capacity of the Isuzu 4LE1NYGV-03G?

The Isuzu 4LE1NYGV-03G engine has an oil capacity of 3.5 liters.

What is the displacement of the Isuzu 4LE1NYGV-03G?

The Isuzu 4LE1NYGV-03G has a displacement of 2.2 liters with 4 cylinders.

Which generators use the Isuzu 4LE1NYGV-03G engine?

The Isuzu 4LE1NYGV-03G powers 2 generator set(s), including Isuzu 4LE1NYGV-03G, Magnum MLG20ICAN.

What is a common problem with the Isuzu 4LE1NYGV-03G engine?

A commonly reported issue on generators using the Isuzu 4LE1NYGV-03G is: Mast lights on but the light output is low. Fix: 1. Fixture or lens are dirty. Clean reflective surface inside fixture and both inside and outside surface of glass lens. Use mild soap and water to clean lens. Other chemicals may have an adverse effect on the glass. 2. Bulb worn due to normal use. Replace bulb. 3. Check the mast coil cord, mast junction box and mast light connections. 4. Generator output incorrect. Check the incoming voltage to the ballast. Incoming voltage should be 120V +/- 5V. If voltage is incorrect, engine speed may need to be adjusted or generator may require service. 5. Low transformer output. The voltage from the transformer should read approximately 400 VAC as the light “strikes” (induces an arc), then drop and slowly rise back up to stabilize at 240-260 VAC. On quick disconnect models, measure across the junction box terminals when the light is unplugged. On hard wired models, remove the mast junction box cover and insert the wire probes into the connector blocks for the light and ground. If proper voltage is not achieved, perform capacitor check to determine if the capacitor or coil needs to be replaced..