The Generac V-type 6.8L is a 6.8 L naturally aspirated engine. It powers generator sets from Generac, including the V-10 6.8L.

Also known as: Generac V-type 6.8L

6.8 L
Displacement

Engine specifications

Displacement6.8 L
AspirationNaturally Aspirated

Common problems

7
  • No AC output from generator.
    Cause: Check main line circuit breaker; Check circuit breaker & fuses; Transfer switch set to NORMAL position; Generator internal failure; Thermal circuit breaker open
    Fix: 1. Reset to ON or CLOSED; 2. Reset and replace, if necessary; 3. Set to GENERATOR position; 4. *; 5. Auto-reset - Wait 5 min. and attempt restart
  • Fuel System Fault FuelSys006
  • Engine won’t crank.
    Cause: 15 amp fuse blown; Loose or corroded or defective battery cables; Defective starter contactor; Defective starter motor; Dead or Defective Battery; 5 amp fuse blown
    Fix: 1. Replace fuse; 2. Tighten, clean or replace battery cables as necessary; 3. Replace contactor; 4. Replace starter motor; 5. Remove, change or replace battery
  • Engine starts then shuts down.
    Cause: Engine oil level is low; Engine is overheated; Defective Low Oil Pressure Switch; Defective Coolant Temperature Switch; Defective Control Module circuit board; Coolant Level is Low; Defective Low Coolant Level Switch
    Fix: 1. Check oil and add oil as needed; 2. Check cooling system for leaks; 3. Replace switch; 4. Replace switch; 5. Replace board; 6. Repair leak - Add coolant; 7. Replace Switch
  • Engine starts hard, runs rough.
    Cause: Flame arrestor (air cleaner) plugged or damaged; Plugged fuel line; Defective spark plugs; Fuel pressure incorrect
    Fix: 1. Clean or replace as needed; 2. Unclog fuel line; 3. Clean, regap or replace plugs; 4. Confirm fuel pressure to regulator is as recommended in SPECIFICATIONS
  • Engine cranks but won't start.
    Cause: Out of fuel; Fuel solenoid (FS) is defective; Open Wire #14A from Engine Control circuit board; Spark plugs defective; Door on tank not closed
    Fix: 1. Replenish fuel; 2. Replace solenoid; 3. Reconnect wire; 4. Clean, regap or replace plugs; 5. Close door on tank
  • AUTO/OFF/MANUAL Switch at OFF, engine continues to run.
    Cause: Defective AUTO/OFF/MANUAL switch; Open/disconnected wire #15A between AUTO/OFF/MANUAL switch and Control Module circuit board; Defective Control Module circuit board
    Fix: 1. Replace switch; 2. Reconnect/close wire; 3. Replace board

Compiled from service & troubleshooting documentation across every generator set that uses the Generac V-type 6.8L.

Service intervals

18
ItemActionHoursMonthsNotes
Engine oil levelCheck10 hr1 moAt least every 20 hours of operation or prior to use
Engine break-in oil and filterChange30 hrFirst service — First 30 operating hours
Engine oil and oil filterChange100 hrFirst service — First 100 operating hours; thereafter every 150 hours or 6 months
Air cleanerClean500 hrService air cleaner
Engine DC alternatorCheck500 hr
StarterCheck500 hr
Battery state of charge and conditionCheck3 moPerformed by authorized service dealer
Cooling systemDrain12 moFlush cooling system
Cooling systemInspect1 moAt least once each month
Engine governorTest12 moAdjust or repair if needed
Engine ignition systemCheck3 mo
Engine safety devices (low oil pressure, low coolant level, high coolant temperature)Test6 mo
Exhaust systemInspect3 mo
Fan beltsCheck3 mo
Fuel systemTest3 mo
GeneratorClean12 moClean, inspect generator
Spark plugsClean12 moClean/re-gap or replace as necessary
Transfer switchCheck3 mo

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Service specifications

4
TypeItemValueUnitCondition
GapSpark plug gap1.14mm (0.045 inch)
OtherBelt tension deflection (midway between pulleys)3/8 to 5/8inch (10 to 16 mm)22 pounds (10 kg) force
SpeedEngine timing BTDC at 1800 rpm (6.8L NG/LP)22degrees1800 rpm
SpeedEngine timing BTDC at 3600 rpm (6.8L NG/LP)24degrees3600 rpm

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Recommended fluids

FluidGradeStandardAmbientCapacityNotes
Coolant50-50 low silicate ethylene glycol base anti-freeze and deionized waterLow silicate anti-freeze4.5 U.S. gal.Add high quality rust inhibitor if desired
Engine oil5W-20 (factory fill); 5W-30For Service SJ or SH5.0 U.S. qts.Use 5W-30 synthetic oil below 32°F
FuelNatural gas at least 1,000 Btu/cu ft; LP gas at least 2,520 Btu/cu ftOperating fuel pressure 11 in. - 14 in. water column
Gear oilSAE 90 gear lubricantFor generator gearbox (if equipped)

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Procedures

8
Spark Plugs adjustment

⚠ Do not blast the spark plugs to clean.

Tools: wire feeler gauge, wire brush

  1. Clean the area around the base of the spark plugs.
  2. Remove the spark plugs and check the condition. Replace if worn.
  3. Check the spark plug gap using a wire feeler gauge. Adjust gap to 1.14 mm (0.045 inch).
Catalyst and Heat Shield Assembly installation

⚠ Catalyst must be mounted in described position.

  1. Disconnect battery cables; disconnect negative first.
  2. Insert outlet pipe 2 to 3 inches into outlet of catalyst; slide one U-bolt onto outlet and tighten.
  3. Slide remaining U-bolt and catalyst over exhaust pipe; insert 2 to 3 inches into inlet; align flat side; tighten U-bolt.
  4. Sub-assemble heat shield panels and cap using screws provided.
  5. Slide heat shield subassembly over the catalyst.
  6. Fasten heat shield assembly to enclosure using screws provided.
  7. Install rain cap over outlet of catalyst and tighten.
Preparation for Start-up (Start-up Checklist) installation

Tools: manometer

  1. Ensure the 120VAC circuit breaker to the battery charger is open.
  2. Remove the 15 Amp ATO fuse from the control panel.
  3. Connect the battery cables to the battery; attach negative cable last.
  4. Close the 120VAC circuit breaker to the battery charger.
  5. Measure battery voltage before and after charger is turned on.
  6. Verify all AC electrical connections are tight.
  7. Check all hoses, clamps, fittings for leaks or damage.
  8. Open the valve to the engine fuel line and bleed the fuel system of air.
  9. Open the generator main line circuit breaker.
  10. Connect a manometer to the gas line and record static pressure.
  11. Insert the fuse into the control panel.
  12. Move the AUTO/OFF/MANUAL switch to manual; engine should crank and start.
  13. Check voltage at the generator terminals and phase rotation for 3-phase units.
  14. Close the generator main line circuit breaker and turn the set off.
Battery Maintenance maintenance

⚠ Storage batteries give off explosive hydrogen gas.

⚠ Battery electrolyte fluid is an extremely caustic sulfuric acid solution.

⚠ Do not use any jumper cables or booster battery to crank and start the generator engine.

Tools: automotive-type battery hydrometer

  1. Inspect the battery posts and cables for tightness and corrosion. Tighten and clean as necessary.
  2. Check the battery fluid level of unsealed batteries and fill with DISTILLED WATER ONLY.
  3. Have the state of charge and condition checked with an automotive-type battery hydrometer.
Changing Engine Oil maintenance

⚠ Hot oil may cause burns. Allow engine to cool before draining oil.

⚠ NEVER OPERATE ENGINE WITH OIL BELOW THE DIPSTICK ADD MARK.

  1. Remove OIL DRAIN HOSE from its retaining clip.
  2. Loosen and remove OIL DRAIN HOSE CAP. Drain oil completely into suitable container.
  3. Install and tighten OIL DRAIN HOSE CAP, re-install into its retaining clip.
  4. Turn OIL FILTER counterclockwise and remove. Dispose of old filter.
  5. Apply light coating of new engine oil to seal of new oil filter. Install and tighten by hand only.
  6. Remove OIL FILL CAP. Add recommended oil. Do not fill above dipstick FULL mark.
  7. Start engine and check for oil leaks.
  8. Shut OFF engine and wait 10 minutes for oil to settle. Recheck oil level.
  9. Dispose of used oil at a proper collection center.
Changing the Engine Air Cleaner maintenance
  1. Remove the air cleaner cover.
  2. Replace the air filter making sure it is positioned properly before reattaching the cover.
Engine Start-up and Transfer operation

⚠ Do not crank the engine continuously for longer than 30 seconds.

  1. Turn OFF or disconnect the utility power circuit to the transfer switch.
  2. Set the transfer handle to its UTILITY (NORMAL) position.
  3. Set the generator's main line circuit breaker to its OFF position.
  4. Start the generator.
  5. Let engine stabilize and warm up.
  6. Check all applicable instrument and gauge readings.
  7. Move the transfer switch manual handle to STANDBY position.
  8. Set the generator's main line circuit breaker to its ON position.
Retransfer and Shutdown operation
  1. Set the generator's main line circuit breaker to its OFF position.
  2. Manually move the transfer switch handle to its UTILITY (NORMAL) position.
  3. Turn ON the utility power supply to the transfer switch.
  4. Let the generator run at no-load for a few minutes to stabilize internal temperatures.
  5. Shut down the generator.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Voltage reconnection

VoltagePhaseConnectionLeadsNotes
120/208V3Stator Power Winding Connections - 3-phase, Y configuration6L-L 208V; L-N 120V
120/240V3Stator Power Winding Connections - 3-phase, Delta configuration6Rated voltage E1-E2, E1-E3, E2-E3 is 240V; E1 or E3 to neutral 00 is 120V
240V1Four-lead, Single-phase Stator (voltage code A)4Rated voltage between terminals 240V; terminal to neutral 00 is 120V
277/480V3Stator Power Winding Connections - 3-phase, Y configuration6L-L 480V; L-N 277V
346/600V3Stator Power Winding Connections - 3-phase, Y configuration6L-N 346V

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Common questions

What is the displacement of the Generac V-type 6.8L?

The Generac V-type 6.8L has a displacement of 6.8 liters.

Which generators use the Generac V-type 6.8L engine?

The Generac V-type 6.8L powers 1 generator set(s), including Generac V-10 6.8L.

What is a common problem with the Generac V-type 6.8L engine?

A commonly reported issue on generators using the Generac V-type 6.8L is: No AC output from generator.. Cause: Check main line circuit breaker; Check circuit breaker & fuses; Transfer switch set to NORMAL position; Generator internal failure; Thermal circuit breaker open. Fix: 1. Reset to ON or CLOSED; 2. Reset and replace, if necessary; 3. Set to GENERATOR position; 4. *; 5. Auto-reset - Wait 5 min. and attempt restart.