The Generac 220c is a 0.22 L engine. It powers generator sets from Generac, including the IMPACT 36 and Impact 36 Plus.
Also known as: Generac 220c
| Displacement | 0.22 L |
|---|
| Item | Action | Hours | Months | Notes |
|---|---|---|---|---|
| Engine oil level | Check | 8 hr | or before each use | |
| Oil filter | Change | 8 hr | First service — first filter change | |
| Air cleaner paper filter | Clean | 25 hr | 12 mo | whichever comes first |
| Air cleaner paper filter | Replace | 25 hr | 12 mo | Replace if too dirty |
| Engine oil | Change | 100 hr | First service — thereafter; more frequently under heavy load or high ambient temp | |
| Oil filter | Replace | 100 hr | First service — thereafter | |
| Valve clearance | Adjust | 50 hr | First service — after first 50 hours of operation | |
| Air intake screen | Clean | 100 hr | Clean more often if necessary | |
| Fuel filter | Replace | 100 hr | 12 mo | whichever occurs first |
| Spark arrestor | Clean | 100 hr | Inspect and clean spark arrestor | |
| Spark arrestor muffler | Inspect | 100 hr | ||
| Spark plug | Clean | 100 hr | clean and set gap 0.030 inch | |
| Battery | Test | 6 mo | Every six months check battery state of charge with an automotive battery hydrometer | |
| Battery state of charge | Test | 6 mo | every six months, by automotive service facility | |
| Battery state of charge and condition | Test | 6 mo | Every six months using an automotive battery hydrometer. |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Type | Item | Value | Unit | Condition |
|---|---|---|---|---|
| Clearance | Exhaust system clearance to combustible material | 3 | inches (76mm) | minimum |
| Clearance | Exhaust system extension past outer edge of vehicle | 1 | inch (25mm) | minimum |
| Clearance | Exhaust system to combustible material clearance | 3 | inches | (76mm) minimum |
| Clearance | Fuel line clearance to exhaust system parts | 2 | inches | minimum |
| Clearance | Throttle lever stop tab to stop block gap | 0.003 | inch (0.08-0.5mm) | engine coasting to a stop |
| Clearance | Throttle linkage gap between stop tab and stop block | 0.003 | inch (0.08-0.5mm) | minimum gap for throttle linkage adjustment |
| Gap | Spark plug gap | 0.030 | inch (0.8mm / 0.76mm) | |
| Other | Engine oil capacity | 950 | mL (1 quart) | |
| Other | Flexible fuel hose length | 6 | inches | at least 6 inches longer than needed |
| Other | Generator compartment clearance around generator | 1 | inch (2 inches recommended) | all sides and ceiling |
| Other | Generator fuel pickup tube shorter than vehicle engine pickup tube | 2 to 3 | inches | recommended |
| Other | Generator mounting bolts | 3/8"-16 | four hardened steel bolts Grade 5; at least 3 threads visible past lock nuts when tight | |
| Other | Minimum air inlet opening (unrestricted) | 40 | square inches | divide by free air inlet area percentage for restricted openings |
| Other | Recommended minimum LP gas flow rate for air-cooled Impact-34 plus series generators | 67 | cubic feet per hour | |
| Pressure | LP fuel system leak test pressure | 90 | psi (620 kPa) | minimum; use soap and water or equivalent |
| Pressure | LP gas pressure at gaseous fuel solenoid valve / secondary regulator | 11 | inches water column | optimum; do not exceed 14 inches water column |
| Pressure | LP gas pressure at inlet to gaseous fuel solenoid valve and secondary regulator | 11 | inches water column | Optimum; do not exceed 14 inches water column |
| Pressure | LP gas pressure at outlet of secondary regulator | 1 | inch water column (negative) | |
| Pressure | LP gas system leak test pressure | 90 | psi | Not less than 90 psi (620 kPa) |
| Speed | Engine speed | Variable, computer controlled | no manual adjustment; do not physically adjust or control engine speed | |
| Temperature | Combustible material temperature rise | 117 | °F | Maximum above ambient if 3-inch clearance cannot be maintained; (65°C) |
| Temperature | Maximum combustible material temperature rise above ambient air temperature | 117 | °F (65°C) | where 3-inch clearance cannot be maintained |
| Torque | Rocker arm jam nut | 65-85 | inch-pounds (7-10 N-m) | after adjusting valve clearance |
| Valve clearance | Valve clearance | 0.001-0.003 | inch (0.03-0.07mm) | engine at room temperature, piston at TDC of compression stroke, both valves closed |
| Voltage | Battery cable voltage drop | 0.12 | volts | Maximum per 100 amperes of cranking current between battery terminals and generator connection point |
| Voltage | Battery cable voltage drop between battery terminals and generator connection point | 0.12 | volts per 100 amperes of cranking current | should not exceed; for best cold weather starting |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Fluid | Grade | Standard | Ambient | Capacity | Notes |
|---|---|---|---|---|---|
| Engine oil | SAE 30 | 950.0 ml | Summer months; acceptable substitute is SAE 10W-30. | ||
| Engine oil | SAE 30 (summer); SAE 5W-30 (winter); SAE 10W-30 acceptable summer substitute | 950.0 mL (1 quart) | Do not use SAE 10W-40. Use no special additives. | ||
| Engine oil | SAE 30 (summer); acceptable substitute SAE 10W-30 (summer) | 950.0 ml (about 1 quart) | DO NOT USE SAE 10W-40 | ||
| Engine oil | SAE 5W30 | 950.0 ml | Winter months; DO NOT USE SAE 10W-40. | ||
| Engine oil | SAE 5W30 (winter) | 950.0 ml (about 1 quart) | |||
| Fuel | LP gas (propane/butane vapor withdrawal) | Impact-34 plus (LP unit); propane vaporizes to -20F(-29C), butane to 32F(0C) | |||
| Fuel | LP gas (propane/butane) | Vapor withdrawal type fuel system | LP units. | ||
| Fuel | Unleaded gasoline | High quality unleaded; leaded REGULAR grade acceptable substitute; ethanol maximum 10 percent; no methanol | Gasoline units. | ||
| Fuel | Unleaded gasoline (leaded regular acceptable substitute); no more than 10% ethanol; no methanol | Impact-36 plus (gasoline unit) | |||
| Fuel | Unleaded gasoline (leaded regular grade acceptable substitute) | Max 10% ethanol if alcohol present; no methanol | Unleaded reduces lead and carbon deposits; remove alcohol-containing gasoline during storage | ||
| Fuel | LP gas (propane, butane or mixture) | above -29°C | Vapor withdrawal type system only. Propane vaporizes as low as -20°F (-29°C); butane returns to liquid below about 32°F (0°C). | ||
| Other | Distilled water | Battery electrolyte top-up only; DO NOT USE TAP WATER IN BATTERY. |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
⚠ Do not overbend the spring clip or the clip will lose its clamping force.
Tools: Pliers
Tools: allen wrench, feeler gauge, crows foot torque wrench
⚠ Do not overbend the spring clip or it will lose its clamping force
Tools: pliers
⚠ Before maintenance, disconnect battery cables; disconnect negative first and reconnect last.
⚠ No leakage is permitted; correct any leakage immediately.
⚠ DO NOT USE ANY FLAME TO TEST FOR LEAKS.
Tools: Separate 12 volts DC source, Soap and water or equivalent solution
⚠ Do not allow the unit to overheat during prolonged operation.
⚠ DO NOT FILL ABOVE FULL MARK
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Voltage | Phase | Connection | Leads | Notes |
|---|---|---|---|---|
| DC output leads | +DC (Red), -DC (Blue), Return (Black), Ground (Green) | Route from generator DC output leads through approved flexible conduit to terminal block in DC junction box on inverter | ||
| Remote panel receptacle | Wire #0 (Ground), Wire #14 (Engine run signal), Wire #17 (Crank), Wire #18 (Stop) | Optional remote-mounted start/stop panel | ||
| 12 | Battery cables | Positive to large lug on starter contactor; Negative to frame ground | Cable size by length: 0-10 ft (0-3m): No.2; 11-15 ft (3.4-4.5m): 0; 16-20 ft (4.5-6m): 000. For warm weather use No.2 cable up to 20 feet. | |
| 120 | Single Phase | AC output | T1 (Black), T2 (White), Green ground | From AC output junction box on inverter to double-pole double-throw transfer switch or approved isolation receptacle. |
| 120 | single | AC output | T1 (Black), T2 (White), Green ground | From AC output junction box on inverter to double-pole double-throw transfer switch or approved isolation receptacle |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
The Generac 220c has a displacement of 0.22 liters.
The Generac 220c powers 2 generator set(s), including Generac IMPACT 36, Generac Impact 36 Plus.