Home›Engines›Ford LSG 875-6005

Ford LSG 875-6005 Engine

The Ford LSG 875-6005 is an engine. It powers generator sets from Cummins/Onan, including the 3 phase 60 Hz UR.

Also known as: Ford LSG 875-6005

Part of the Ford LSG875 engine family — 3 variants share parts & fitment.

Engine specifications

Generator sets powered by this engine

1

Common problems

15
  • The FAULT 2 fault lamp lights. Engine shuts down immediately, engine runs for several seconds and then shuts down, or engine continues to run FAULT 2
    Cause: The standard undesignated fault functions are programmed to shut down the set when a fault is sensed. Fault 2 is immediate. The nature of the fault is an optional selection that is determined when the set installation is designed. The undesignated fault functions may also be programmed for non-shutdown or non time delay.
  • The FAULT 1 or FAULT 2 fault lamp lights. FAULT 1 or FAULT 2
    Fix: Engine shuts down immediately, engine runs for several seconds and then shuts down, or engine continues to run. The standard undesignated fault functions are programmed to shut down the set when a fault is sensed. Fault 1 is timed delay while Fault 2 is immediate. The nature of the fault is an optional selection that is determined when the set installation is designed. The undesignated fault functions may also be programmed for non-shutdown or non time delay. Engine shuts down immediately, engine runs for several seconds and then shuts down, or engine continues to run.
  • The FAULT 1 fault lamp lights. Engine shuts down immediately, engine runs for several seconds and then shuts down, or engine continues to run FAULT 1
    Cause: The standard undesignated fault functions are programmed to shut down the set when a fault is sensed. Fault 1 is timed delay. The nature of the fault is an optional selection that is determined when the set installation is designed. The undesignated fault functions may also be programmed for non-shutdown or non time delay.
  • SWITCH OFF lamp flashes
    Cause: Start/Stop/Remote switch is in the Stop position which will prevent automatic starting if an automatic transfer switch is used
    Fix: Move the Start/Stop/Remote switch to the Remote position for automatic starting.
  • PRE LO OIL PRES lamp lights. Engine continues to operate
    Cause: Engine oil pressure has dropped to 30 psi (207 kPa)
    Fix: If engine can be stopped, follow procedures in step 5. If generator is powering critical loads and cannot be shut down, wait until next shutdown period and then follow step 5 procedure.
  • PRE HI ENGINE TEMP lamp lights. Engine continues to operate
    Cause: Engine has begun to overheat and engine temperature has risen to approximately 205°F (97°C)
    Fix: If engine can be stopped, follow procedures in step 3. Use the following procedures if generator is powering critical loads and cannot be shutdown: Check air inlets and outlets and remove any obstructions to airflow; Open doors or windows in generator area to increase ventilation; Reduce load if possible by turning off non-critical loads.
  • OVERCRANK lamp lights and engine stops cranking
    Cause: Possible fuel or ignition system problem
    Fix: Check fuel leaks, or plugged fuel lines and correct as required; Check for dirty fuel filter and replace if necessary (see MAINTENANCE section); Check for dirty or plugged air filter and replace if necessary (see MAINTENANCE section); Check for loose connections in the ignition primary, ignition secondary, or solenoid valve circuits and correct as required; Reset the control and restart after correcting the problem. Contact an Onan Dealer or Distributor for service if none of the above.
  • No AC output voltage
    Cause: Field breaker is tripped
    Fix: Reset breaker. Contact an Onan Dealer or Distributor if voltage build up causes breaker to trip.
  • LO OIL PRES lamp lights. Engine shuts down
    Cause: Engine oil pressure has dropped to 25 psi (172 kPa)
    Fix: Check oil level and replenish if low. Reset control and restart. Contact an Onan Dealer or Distributor if oil pressure is not in the range of 30-55 psi (207 to 380 kPa).
  • LO ENG TEMP lamp lights. Set is in standby mode but is not operating. (Lamp lights when engine water jacket temperature is 70°F (21°C) or lower. Since the lamp goes out after the engine warms up, there should be no cause for alarm even during initial generator set operation.)
    Cause: Engine coolant heater is not operating or is not circulating coolant
    Fix: Check for the following conditions: Coolant heater not connected to power supply. Check for blown fuse or disconnected heater cord and correct as required; Check for low coolant level and replenish if required. Look for possible coolant leakage points and repair as required; Contact an Onan Dealer or Distributor if none of the above.
  • HI ENG TEMP lamp lights. Engine shuts down
    Cause: Engine has overheated (engine temperature has risen above 215°F/102°C) or coolant level is low (sets with coolant level sensor)
    Fix: Allow engine to cool down completely before proceeding with the following checks: Check coolant level and replenish if low. Look for possible coolant leakage points and repair if necessary; Check for obstructions to cooling airflow and correct as necessary; Check for a slipping fan belt and tighten if loose; Reset control and restart after locating and correcting problem. Contact an Onan Dealer or Distributor if none of the above.
  • Green RUN lamp lights following engine start-up
    Fix: Indicates all engine systems are normal. No corrective action required.
  • Green RUN lamp does not light following engine start-up
    Cause: Possible Start/Disconnect relay failure
    Fix: Contact an Onan Dealer or Distributor for assistance.
  • Fault lamp lights but no fault exists, Engine gauges show oil pressure, engine temperature, and frequency (speed) are within normal limits
    Cause: The monitor board or a sensor may be at fault
    Fix: Reset control. If control will not reset, the monitor board or a sensor may be at fault. Contact an Onan Dealer or Distributor for service.
  • Engine will not crank
    Cause: Possible fault with control or starting system
    Fix: Check for the following conditions: Fault lamp on. Correct fault and reset control; Poor battery cable connections. Clean the battery cable terminals and tighten all connections; Discharged or defective battery. Recharge or replace the battery; Contact an Onan Dealer or Distributor for assistance if none of the above.

Compiled from service & troubleshooting documentation across every generator set that uses the Ford LSG 875-6005.

Parts cataloged across the Ford LSG875 family

56
Part #DescriptionCategory
952-696GasketGasket
276206Hose, moldedHose
X-309-16Clamp, hoseHose
X-380-1Connector, 1/8NPT x 1/4 in. ID hoseHose
X-386-56Fuel line, flexibleHose
X-577-6Hose, 5/8 ID x 11Hose
X-797-1Hose, flexHose
X-797-11Hose, flexHose
X-797-2Hose, flexHose
276378Installed Block Heater Kit / Interim Kit (120V)Service part / kit
276379Installed Block Heater Kit / Interim Kit (240V)Service part / kit
276691Block HeaterService part / kit
276692Block HeaterService part / kit
285054Silencer Residential R-M (Table 3)Service part / kit
285086Silencer Industrial I-N (Table 3)Service part / kit
285127Silencer Industrial I-N (Table 1)Service part / kit
285775Silencer Residential R-M (Table 1)Service part / kit
286788Silencer Critical C-BM (Table 1)Service part / kit
290483Silencer Residential R-BM (Table 1)Service part / kit
290484Silencer Residential R-N (Table 1)Service part / kit
290485Silencer Residential R-BM (Table 3)Service part / kit
290486Silencer Residential R-N (Table 3)Service part / kit
290489Silencer Critical C-M (Table 3)Service part / kit
290490Silencer Critical C-N (Table 3)Service part / kit
290495Silencer Critical C-M (Table 1)Service part / kit
290496Silencer Critical C-N (Table 1)Service part / kit
326174Installed Block Heater Kit (120V)Service part / kit
326175Installed Block Heater Kit (240V)Service part / kit
326234Block HeaterService part / kit
326235Block HeaterService part / kit
326279Changeover KitService part / kit
326280Changeover KitService part / kit
952-048Pipe Plug 3/8 - 18 x .42 socket hexService part / kit
952-234Bolt - 5/16 - 18 x .875Service part / kit
952-486Dowel - 1/2 x 1.00Service part / kit
952-539Bolt - 5/16 - 18 x 2.00Service part / kit
952-553Plug - Oil Passage In Block - 1/4 NPTService part / kit
952-554Plug - Water Drain - 1/4 NPT - BrassService part / kit
952-556DowelService part / kit
952-561Plug - .060 O/SService part / kit
952-563Plug - 5/8 - 18Service part / kit
952-569Plug - Camshaft Rear Bearing - StandardService part / kit
952-570Plug - Camshaft Rear Bearing - .060 O/SService part / kit
952-577PointerService part / kit
952-596Plug - 1.50 CupService part / kit
952-688CoverService part / kit
952-689BlockService part / kit
DZAE-6730-AAoil pan drain plugService part / kit
E5AE-6730-AAmetric drain plugService part / kit
C20E-6734-Aold drain plug sealSeal
EQEE-6734-AAmetric drain plug sealSeal
ESAE-6734-AAdrain plug sealSeal
241481Switch, high temperature 268298 Sender, water temperatureSensor
255264Switch, low water temperatureSensor
255913Switch, pressureSensor
271425Switch, anticipatory low oil pressureSensor

Parts cataloged across all variants of this engine family — verify the exact part fits your specific variant and serial number before ordering.

Common questions

Which generators use the Ford LSG 875-6005 engine?

The Ford LSG 875-6005 powers 1 generator set(s), including Cummins/Onan 3 phase 60 Hz UR.

What is a common problem with the Ford LSG 875-6005 engine?

A commonly reported issue on generators using the Ford LSG 875-6005 is: The FAULT 2 fault lamp lights. Engine shuts down immediately, engine runs for several seconds and then shuts down, or engine continues to run. Cause: The standard undesignated fault functions are programmed to shut down the set when a fault is sensed. Fault 2 is immediate. The nature of the fault is an optional selection that is determined when the set installation is designed. The undesignated fault functions may also be programmed for non-shutdown or non time delay..