Maintenance schedule
| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Oil filter | Cartridge | — | |||
| Oil | 47.1 L | — |
Pooled from every document that names this exact engine — confirm the interval and part number against your unit's serial number.
The Doosan D219TIC is a 21.9 L turbocharged, charge air-cooled engine rated at 1800 rpm. It powers generator sets from Kohler, including the 400REZX and 400RZX. It holds 47.1 L (12.4 gal) of oil and 242 L (63.9 gal) of coolant.
Also known as: Doosan D219TIC
| Oil capacity | 47.1 L |
|---|---|
| Coolant capacity | 242.0 L |
| Displacement | 21.9 L |
| Aspiration | Turbocharged, Charge Air-Cooled |
| Rated speed | 1800 rpm |
Compiled from service & troubleshooting documentation across every generator set that uses the Doosan D219TIC.
| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Oil filter | Cartridge | — | |||
| Oil | 47.1 L | — |
Pooled from every document that names this exact engine — confirm the interval and part number against your unit's serial number.
| Type | Item | Value | Unit | Condition |
|---|---|---|---|---|
| Gap | Speed sensor air gap | 0.36- 0.71 | mm | |
| Other | 10 in. weld flange bolt circle diameter B | 361.95 | mm (14.25 in.) | |
| Other | 10 in. weld flange outside diameter C | 406.4 | mm (16.0 in.) | |
| Other | 10 in. weld flange quantity of bolts / bolt hole diameter D | 12, 25.40 | mm (1.00 in.) | |
| Other | 12 in. weld flange bolt circle diameter B | 431.80 | mm (17.00 in.) | |
| Other | 12 in. weld flange outside diameter C | 482.6 | mm (19.0 in.) | |
| Other | 12 in. weld flange quantity of bolts / bolt hole diameter D | 12, 25.40 | mm (1.00 in.) | |
| Other | 14 in. weld flange bolt circle diameter B | 476.25 | mm (18.75 in.) | |
| Other | 14 in. weld flange outside diameter C | 533.4 | mm (21.0 in.) | |
| Other | 14 in. weld flange quantity of bolts / bolt hole diameter D | 12, 28.58 | mm (1.13 in.) | |
| Other | 16 in. weld flange bolt circle diameter B | 539.75 | mm (21.25 in.) | |
| Other | 16 in. weld flange outside diameter C | 596.9 | mm (23.5 in.) | |
| Other | 16 in. weld flange quantity of bolts / bolt hole diameter D | 16, 28.58 | mm (1.13 in.) | |
| Other | 18 in. weld flange bolt circle diameter B | 577.85 | mm (22.75 in.) | |
| Other | 18 in. weld flange outside diameter C | 635.0 | mm (25.0 in.) | |
| Other | 18 in. weld flange quantity of bolts / bolt hole diameter D | 16, 31.75 | mm (1.25 in.) | |
| Other | 20 in. weld flange bolt circle diameter B | 635.00 | mm (25.00 in.) | |
| Other | 20 in. weld flange outside diameter C | 698.5 | mm (27.5 in.) | |
| Other | 20 in. weld flange quantity of bolts / bolt hole diameter D | 20, 31.75 | mm (1.25 in.) | |
| Other | 5 in. weld flange bolt circle diameter B | 215.90 | mm (8.50 in.) | |
| Other | 5 in. weld flange outside diameter C | 241.30 | mm (9.50 in.) | |
| Other | 5 in. weld flange quantity of bolts / bolt hole diameter D | 8, 22.23 | mm (0.88 in.) | |
| Other | 6 in. weld flange bolt circle diameter B | 254.0 | mm (10.0 in.) | |
| Other | 6 in. weld flange outside diameter C | 279.4 | mm (11.0 in.) | |
| Other | 6 in. weld flange quantity of bolts / bolt hole diameter D | 8, 22.23 | mm (0.88 in.) | |
| Other | 8 in. weld flange bolt circle diameter B | 298.45 | mm (11.75 in.) | |
| Other | 8 in. weld flange outside diameter C | 342.9 | mm (13.5 in.) | |
| Other | 8 in. weld flange quantity of bolts / bolt hole diameter D | 8, 22.23 | mm (0.88 in.) | |
| Other | Weld flange angle A (10, 12, 14 in. nominal pipe size) | 30 | deg. | |
| Other | Weld flange angle A (16, 18, 20 in. nominal pipe size) | 22.5 | deg. | |
| Other | Weld flange angle A (5, 6, 8 in. nominal pipe size) | 45 | deg. | |
| Pressure | Battery equalizer input voltage (24 volts nominal) | 20- 35 | volts | |
| Pressure | Battery equalizer output voltage | (input voltage/2) ±2% | volts | |
| Pressure | Pressure switch 364345 | 483 ±14 | kPa | |
| Resistance | Pressure sender 264390 value A | 240 +17/- 15 | ohms at 0 psi | |
| Resistance | Pressure sender 264390 value B | 153 +12/- 15 | ohms at 25 psi | |
| Resistance | Pressure sender 264390 value C | 33.5 | ohms at 100 psi | |
| Resistance | Pressure sender 365624 value A | 241 ±16 | ohms at 0 psi | |
| Resistance | Pressure sender 365624 value B | 152 ±13 | ohms at 50 psi | |
| Resistance | Pressure sender 365624 value C | 33.5 | ohms at 200 psi | |
| Resistance | Temperature sender 226717 value A | 123.8 +7.2/- 7.8 | ohms at 90.6 C (195 F) | |
| Resistance | Temperature sender 226717 value B | 35.6 +3.4/- 3.6 | ohms at 137.8 C (280 F) | |
| Resistance | Temperature sender 226919 value A | 942 ±22 | ohms at 37.7 C (100 F) | |
| Resistance | Temperature sender 226919 value B | 35 | ohms at 115.6 C (240 F) | |
| Speed | Overspeed shutdown | 70 | Hz | 60 Hz models |
| Temperature | Battery equalizer operating temperature | - 40 to 71 | C (- 40 F to 160 F) | |
| Temperature | Temperature switch 241308 | 107 ±4 | C (225 F ±7 F) | normally open to close on temp. rise |
| Temperature | Temperature switch 290090/GM51705 | 16 ±3 | C (60 F ±5 F) | normally open to close on temp. fall |
| Voltage | Speed sensor voltage, wire 2 (black) & 16 (white) | 3- 6 | volts DC | |
| Voltage | Speed sensor voltage, wire 2 (black) & 24 (red) | 8- 10 | volts DC |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
⚠ Hazardous voltage. Moving parts. Will cause severe injury or death. Operate the generator set only when all guards and electrical enclosures are in place.
⚠ Disconnecting the electrical load. Hazardous voltage will cause severe injury or death.
Tools: Voltmeter, Wattmeter
Tools: Voltmeter
⚠ Hot engine and exhaust system can cause severe injury or death. Do not work on the generator set until it cools.
⚠ Hazardous voltage. Moving parts. Will cause severe injury or death. Operate the generator set only when all guards and electrical enclosures are in place.
Tools: DC voltmeter
⚠ Hot engine and exhaust system can cause severe injury or death. Do not work on the generator set until it cools.
⚠ Hazardous voltage. Moving parts. Will cause severe injury or death.
Tools: Ohmmeter
⚠ To prevent reverse polarity damage to the battery equalizer, remove the ground (GND) connection first and attach the ground connection last when disconnecting the battery equalizer.
Tools: 12-volt test light with alligator clips, Voltmeter with 0.01 volt resolution, Battery load tester
Tools: Ohmmeter, Mechanical oil pressure gauge
⚠ Keep leads connected to the speed sensor terminals during the test; do not disconnect the leads.
Tools: DC voltmeter
Tools: DC voltmeter, 12-volt battery or DC power supply, Flat piece of iron or steel
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Voltage | Phase | Connection | Leads | Notes |
|---|---|---|---|---|
| 12-lead optional voltage connections | 12 | Alternator optional feature | ||
| 4-lead dedicated voltages | 4 | Alternator standard feature | ||
| 110/127/139/240/254/277 | single-phase | switchable | Towable generator model specifications; some models n/a | |
| 208/220/240/415/440/480 | 3-phase | reconnectable | Towable generator model specifications | |
| 208/220/240/415/440/480 | 3-phase | switchable | Towable generator model specifications |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
The Doosan D219TIC engine has an oil capacity of 47.1 liters.
The Doosan D219TIC has a displacement of 21.9 liters.
The Doosan D219TIC powers 2 generator set(s), including Kohler 400REZX, Kohler 400RZX.
A commonly reported issue on generators using the Doosan D219TIC is: Emergency Stop. Fix: Reset the emergency stop switch..