Home›Engines›Continental Red Seal

Continental Red Seal Engine

The Continental Red Seal is a 4-cylinder engine rated at 1800 rpm. It powers generator sets from Cummins/Onan, including the 5KW GO.

Also known as: Continental Red Seal

4
Cylinders
1800 rpm
Rated speed

Engine specifications

Cylinders4
Rated speed1800 rpm

Generator sets powered by this engine

1

Common problems

15
  • Excessive oil consumption, light blue smoky exhaust
    Cause: Worn piston rings
    Fix: Install new piston rings. See PISTON RING REPLACEMENT
  • Engine misfires at light load
    Cause: Carburetor idle adjustment set wrong or clogged
    Fix: Adjust, clean if needed
  • Low oil pressure
    Cause: Too long screw on center main bearing
    Fix: See MAIN BEARINGS
  • Voltage drops under heavy load
    Cause: Engine lacks power
    Fix: See remedies for engine misfiring under heavy load
  • Engine backfires at carburetor
    Cause: Lean fuel mixture
    Fix: Clean carburetor
  • Engine misfires at all loads
    Cause: Fouled spark plug
    Fix: Clean and adjust
  • Engine overheating
    Cause: Low water in radiator
    Fix: Refill radiator
  • High oil pressure
    Cause: Oil too heavy
    Fix: Drain, refill with proper oil. See PREPARATION
  • Excessive arcing of brushes
    Cause: Rough commutator or rings
    Fix: Turn down
  • Current unsteady but engine not misfiring
    Cause: Speed too low
    Fix: Adjust governor to correct speed
  • Black, smoky exhaust, excessive fuel consumption, fouling of spark plugs with black soot, possible lack of power under heavy load
    Cause: Fuel mixture too rich
    Fix: Adjust choke, install needed carburetor parts, adjust float level
  • Tapping sound
    Cause: Tappet clearance too great
    Fix: Adjust or replace tappets
  • Plant will start but does not continue to run
    Cause: Trouble in one of the relays, the high water temperature switch, or a loose connection (runs with ignition switch at HAND START position)
  • Plant starts but does not continue to run
    Cause: START button released too soon
    Fix: Hold in contact longer
  • Generator overheating
    Cause: Overloaded
    Fix: Reduce load

Compiled from service & troubleshooting documentation across every generator set that uses the Continental Red Seal.

Maintenance schedule

ItemSpecCapacityPart #Interval
Air filterOil bath air cleaner—
Fuel filterFuel pump filter screen—
Oil filterFilter element cartridge—
Battery12-volt automotive battery—
CoolantEngine coolant for radiator11.0 quarts—
OilUndiluted engine oil for crankcase3.0 quarts—50 hr
Spark plugSpark plugs—200 hr

Pooled from every document that names this exact engine — confirm the interval and part number against your unit's serial number.

Common questions

Which generators use the Continental Red Seal engine?

The Continental Red Seal powers 1 generator set(s), including Cummins/Onan 5KW GO.

How often should you change the oil in the Continental Red Seal?

The Continental Red Seal oil change interval is every 50 hours.

What is a common problem with the Continental Red Seal engine?

A commonly reported issue on generators using the Continental Red Seal is: Excessive oil consumption, light blue smoky exhaust. Cause: Worn piston rings. Fix: Install new piston rings. See PISTON RING REPLACEMENT.