HomeEnginesCaterpillar C3.6

Caterpillar C3.6 Engine

The Caterpillar C3.6 is a 3.6 L turbocharged engine rated at 2400 rpm, producing up to 82 kW. It powers generator sets from Kohler, including the 11EFKOZD, 12EFKOZD, 13EFKOZD and 13EKOZD.

Also known as: Caterpillar C3.6

3.6 L
Displacement
2400 rpm
Rated speed
82 kW
Gross power

Engine specifications

Displacement3.6 L
AspirationTurbocharged
Rated speed2400 rpm
Gross power82 kW

Common problems

1
  • Accidental starting
    Fix: Disconnect the battery cables before working on the generator set. Remove the negative (--) lead first when disconnecting the battery. Reconnect the negative (--) lead last when reconnecting the battery.

Compiled from service & troubleshooting documentation across every generator set that uses the Caterpillar C3.6.

Maintenance schedule

ItemSpecCapacityPart #Interval
Air filterwith precleaner, automatic dust ejection and underhood intake
Fuel filter
Oil filter
Batteryheavy duty, maintenance free, 1000 CCA
Belt
Spark plug

Pooled from every document that names this exact engine — confirm the interval and part number against your unit's serial number.

Service intervals

32
ItemActionHoursMonthsNotes
Crankcase oilChange250 hr3 moFirst service — Replace the oil in the crankcase. Break-in period service indicated.
Fuel/water separatorClean250 hr3 moFuel/water separator cleaning.
Fuel/water separatorDrain250 hr3 moFuel/water separator draining. Consult local distributor/dealer for service.
Lube oil filter elementReplace250 hr3 moFirst service — Replace the lube oil filter element. Break-in period service indicated.
Seawater pump belt tensionAdjust250 hr3 moFirst service — Check/adjust the seawater pump belt tension. Break-in period service indicated.
Battery cablesClean500 hr6 moClean the battery cables.
Coolant hosesInspect500 hr6 moCheck the coolant hoses.
Electrical connectionsCheck500 hr6 moCheck and tighten the electrical connections.
Fuel filterReplace500 hr6 moReplace the fuel filter element.
GeneratorClean500 hr6 moBlow dust out of the generator.
Heat exchanger anticorrosion zinc anode (if equipped)Check500 hr6 moCheck the zinc anode.
Mounting bolts/vibromountsCheck500 hr6 moCheck the mounting bolts/vibromounts and tighten if necessary.
Seawater pump impellerInspect500 hr6 moCheck the seawater pump impeller.
Siphon break (if equipped)Check500 hr6 moCheck the function of the siphon break, if equipped.
Breather pipeCheck1000 hr12 moCheck the breather pipe for obstructions.
CoolantReplace1000 hr12 moReplace the coolant.
Coolant hosesReplace1000 hr12 moReplace the coolant hoses.
Exhaust/water mixing elbowClean1000 hr12 moClean the exhaust/water mixing elbow.
Fuel injection nozzle pressureTest1000 hr12 moInspect the fuel injection nozzle pressure (Engine S/M).
Fuel injectorsTest1000 hr12 moInspect, clean, and test the fuel injectors (Engine S/M).
Fuel tank sediment / fuel tankDrain1000 hr12 moRemove the sediment from the fuel tank and drain the fuel tank.
Heat exchanger anticorrosion zinc anode (if equipped)Replace1000 hr12 moReplace the zinc anode.
Heat exchanger tubeClean1000 hr12 moClean the heat exchanger tube (Generator S/M).
Intake/exhaust valve clearanceAdjust1000 hr12 moAdjust the intake/exhaust valve clearance (Engine S/M).
Seawater pump impellerReplace1000 hr12 moReplace the seawater pump impeller.
Slip rings and brushes (6EKOD/5EFKOD models)Clean1000 hr12 mo6EKOD/5EFKOD Models: Clean the slip rings and inspect the brushes (Generator S/M).
Crankcase breather systemInspect1500 hrInspect the crankcase breather system (Engine S/M).
Timing beltReplace4000 hrReplace the timing belt (Engine S/M).
Starter motorCheck5000 hrCheck the starter motor.
EngineOther10000 hrTotal engine overhaul (Engine S/M).
Complete exhaust systemInspect12 moInspect the complete exhaust system.
Remote start panel (if equipped)CheckFirst service — Check the remote start panel operation. Break-in period service indicated.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Service specifications

19
TypeItemValueUnitCondition
GapAnticorrosion zinc anode dimensions10 (0.39) x 17 (0.67)mm (in.)diameter x length
GapSeawater pump belt deflection10mm (0.4 in.)pressing with approx. 10 kg (22 lbs.) force at midpoint of longest span; recheck new belt after 10 minutes of operation
OtherAnticorrosion zinc anode replacement threshold<50% of length/diameterreplace when percent of zinc remaining is below 50%
PressureCrank oil pressure (locked rotor)69kPalocked rotor condition
PressureLow oil pressure shutdown trip point117kPaat or below
PressureLow oil pressure warning trip point138kPaat or below
SpeedEngine over speed shutdown trip point115% of rated speedengine speed exceeds
SpeedEngine under speed shutdown trip point85% of rated speedengine speed falls below
SpeedOverfrequency default setting110% of nominalsetting range 102%-140% of nominal; time delay 10 sec
SpeedUnderfrequency default setting90% of nominalinhibit time 10 sec; delay time 5 sec
TemperatureCoolant freeze protection (50% ethylene glycol)-37°C (-34 °F)50% ethylene glycol solution
TemperatureCoolant overheating protection (50% ethylene glycol)129°C (265 °F)50% ethylene glycol solution
TemperatureHigh coolant temperature shutdown trip point110°C (230 °F)trip point
TemperatureHigh coolant temperature warning trip point105°C (221 °F)trip point
VoltageHigh battery voltage default setting (12 V system)15Vrange 13.2-16.2
VoltageLow battery voltage default setting (12 V system)12Vrange 9.6-12.6
VoltageOvervoltage default setting120% of nominalinhibit time 10 sec; delay time 2 sec
VoltageUndervoltage default setting80% of nominal at 10 secinhibit time 10 sec; delay time 10 sec
VoltageVoltage adjust range±10% of system voltageupper limit +10%, lower limit -10%

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Recommended fluids

FluidGradeStandardAmbientCapacityNotes
Coolant50% ethylene glycol and 50% clean, softened waterabove -37°CProvides freezing protection to -37 °C (-34 °F) and overheating protection to 129 °C (265 °F). Coolant capacities (including 0.24 L (8 oz.) recovery tank): 6EKOD/5EFKOD 3.0 L (3.2 Qts.); 9EKOZD/7EFKOZD 3.0 L (3.2 Qts.); 11EKOZD/9EFKOZD (1 Phase) 4.3 L (4.5 Qts.); 11EKOZD/9EFKOZD (3 Phase) 4.3 L (4.5 Qts.). Do not use alcohol or methanol antifreeze.
Engine oilAPI classification CD or CFSee SAE viscosity selection chart (SAE 20W, 30, 40 mineral base; SAE 10W-30, 10W-40, 10W-60, 15W-40, 20W-60 semi-synthetic base; SAE 5W-30, 0W-30, 10W, 5W-40 synthetic base)Oil capacities: 6EKOD and 5EFKOD 2.5 L (2.6 Qts.); 9EKOZD and 7EFKOZD 2.5 L (2.6 Qts.); 11EKOZD and 9EFKOZD (1 Phase) 3.4 L (3.6 Qts.); 11EKOZD and 9EFKOZD (3 Phase) 3.4 L (3.6 Qts.). Maintain level between Min and Max marks on dipstick.
FuelDiesel fuel oilCetane number minimum 51; viscosity 2.0/4.5 centistokes at 40 °C; density 0.835/0.855 kg/litre; distillation 85% at 350; sulphur maximum 0.05% of weightFuel with low sulphur content: API CF4, CG4. Fuel with high sulphur content: API CF, CD, CE. Never store diesel fuel in galvanized containers. Avoid storing fuel for more than one month.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Fault codes

30
CodeNameMeaningSeverityAction
AC Sens Loss Low ShutdwnAC Sensing Loss (Shutdown)Loss of AC voltage shutdown occurs when the controller does not detect the nominal generator AC output voltage for more than 3 seconds after crank disconnect.ShutdownContact an authorized distributor/dealer for service.
AC Sens Loss WarningAC Sensing Loss WarningLoss of AC voltage warning occurs when the controller does not detect the nominal generator set AC output voltage after crank disconnect.WarningContact an authorized distributor/dealer for service.
Aux Input ShutdwnAuxiliary Input ShutdownAuxiliary fault input shutdown; input from a customer-supplied switch that closes when the fault is active.ShutdownCheck the cause of the auxiliary fault.
Backup Pars StatusBackup Parameters LoadedBackup parameter firmware is now loaded on the controller.Info
Battery High WarningHigh Battery Voltage WarningHigh battery voltage warning; the fault condition clears when the battery voltage returns within limits (above 125% of nominal 12 V).WarningCheck the battery rating and condition.
Battery Low WarningLow Battery Voltage WarningLow battery voltage warning; the fault condition clears when the battery voltage returns within limits (at or below 100% of nominal 12 V).WarningCheck the battery rating and condition. Charge or replace the battery.
Coolnt Temp High ShutdwnHigh Coolant Temperature ShutdownOccurs if the engine coolant temperature exceeds the default setting (at or above 110 °C / 230 °F).ShutdownCheck for a low engine coolant level. Check seawater pump impeller, strainers, and seacock.
Coolnt Temp High WarningHigh Coolant Temperature WarningHigh coolant temperature warning (at or above 105 °C / 221 °F).WarningCheck for a low engine coolant level. Check seawater system for reduced flow. Allow the generator set to cool down before checking.
Eng Speed High ShutdwnEngine Over Speed ShutdownOccurs if the engine speed exceeds the default setting (above 115% of rated speed).ShutdownContact an authorized distributor/dealer for service if problem continues.
Eng Speed Low ShutdwnEngine Under Speed ShutdownOccurs if the engine speed falls below the default setting (below 85% of rated speed).ShutdownContact an authorized distributor/dealer for service.
Engine Start StatusEngine StartedGenerator set start circuit is closed allowing the engine to crank and run.Info
Engine Stop StatusEngine StoppedGenerator set start circuit is open causing the engine to shut down.Info
Exh Temp High ShutdwnHigh Exhaust Temperature ShutdownOccurs if the engine exhaust temperature exceeds the default setting.ShutdownCheck the wiring to the sensor. Check for a clogged seawater intake or sea strainer. Check for a damaged seawater pump impeller. Check the exhaust system.
Frequency High ShutdwnOverfrequency ShutdownOccurs when the governed frequency exceeds the default setting of the system's frequency setpoint (above 110% of nominal).ShutdownContact an authorized distributor/dealer for service if problem continues.
Frequency Low ShutdwnUnderfrequency ShutdownOccurs when the governed frequency falls below the default setting of the system's frequency setpoint (below 90% of nominal).ShutdownReduce the load and restart the generator set. Contact an authorized distributor/dealer if problem continues.
Gen Running NoticeGenerator RunningGenerator set has started and is running.Info
Lo Crank Vlt WarningLow Cranking Voltage WarningLow cranking voltage warning (battery voltage drops below 60% of nominal 12 V).WarningCheck the battery rating and condition. Charge or replace the battery.
Locked Rotor ShutdwnLocked Rotor (Overcrank) ShutdownOvercrank (locked rotor) shutdown; engine speed below 10 rpm and oil pressure below crank oil pressure (69 kPa).ShutdownContact an authorized distributor/dealer for service if problem continues.
Oil Pres Low ShutdwnLow Oil Pressure ShutdownOccurs if a low oil pressure condition exists (at or below 117 kPa). Note: does not protect against low oil level.ShutdownCheck for leaks in the lubrication system. Check the oil level and add oil if the level is low.
Oil Pres Low WarningLow Oil Pressure WarningLow engine oil pressure warning (at or below 138 kPa).WarningCheck for leaks in the lubrication system. Check the oil level and add oil if the level is low.
Over Crank ShutdwnOvercrank ShutdownOccurs after 3 unsuccessful starting attempts.ShutdownCheck the fuel supply and battery. Also check for loose connections. Contact an authorized distributor/dealer if problem continues.
PreheatEngine Start Aid ActiveStart aid is active and will energize an engine equipped preheat or ether system during the crank cycle.Info
Remote Start StatusRemote StartGenerator set start circuit was closed from a remote location allowing the engine to crank and run.Info
RunRelCoil ShutdwnRun Relay Coil ShutdownOverload or perceived overload on the DC circuits provided through the controller (70 Run, 71 Crank, FP/FN Flash).ShutdownContact an authorized distributor/dealer for service if problem continues.
Sea Pressure Low ShutdwnLow Seawater Pressure ShutdownOccurs after a loss of seawater pressure is detected (5 seconds after detection).ShutdownCheck for a clogged seawater intake or sea strainer. Check for a damaged seawater pump impeller.
Start Delay NoticeEngine Start Delay ActiveThe delay for engine start is active; the unit will start cranking after the time delay times out.Info
System Ready StatusSystem ReadyGenerator set is in the AUTO mode and available to start if the start circuit is closed.Info
Timer Error NoticeSystem Timer FailedController timer logic has failed to time out a designated function.Info
Volts xx-xx High ShutdwnOvervoltage ShutdownOccurs if the voltage exceeds the default setting of the voltage regulator setpoint (exceeds 120% of the AC system voltage).ShutdownContact an authorized distributor/dealer for service if problem continues.
Volts xx-xx Low ShutdwnUndervoltage ShutdownOccurs if the voltage falls below the default setting of the voltage regulator setpoint (below 80% of the AC system voltage).ShutdownReduce the load and restart the generator set. Check the F1 fuse. Contact an authorized distributor/dealer if problem continues.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Procedures

12
Seawater Pump Belt Tensioning Procedure adjustment

⚠ Hazardous voltage. Moving parts. Operate the generator set only when all guards and electrical enclosures are in place.

  1. Remove the belt guard.
  2. Check the belt tension at the midpoint of the longest span by pressing with approx. 10 kg (22 lbs.) of force.
  3. Recheck a new belt tension after 10 minutes of operation.
  4. Loosen the pivot and adjusting screws.
  5. While prying the seawater pump outward, tighten the adjusting screw.
  6. Tighten the pivot screw.
  7. Recheck and adjust as necessary.
  8. Replace the belt guard.
Anticorrosion Zinc Anode Replacement maintenance

Tools: Wire brush

  1. With the generator set cooled, close the seacock, open the petcock on the engine, and drain the coolant.
  2. Remove the anticorrosion zinc anode (plug) from the heat exchanger.
  3. Use a wire brush to remove loose corrosion; replace the anode when <50% of length/diameter remains.
  4. Clean the threaded hole and coat the anode threads with pipe sealant suitable for marine applications.
  5. Cut the anticorrosion zinc to the correct length and install it into the heat exchanger.
  6. Close the petcock, open the seacock, and refill the cooling system.
  7. Start the generator set and check for leaks at the anticorrosion zinc anode location.
Flushing and Cleaning Procedure maintenance

⚠ Hot coolant and steam. Before removing the pressure cap, stop the generator set and allow it to cool.

  1. Open the pressure cap and open petcocks at the heat exchanger, engine block, and cooling system; let the system drain completely.
  2. Drain, clean, and flush the coolant recovery tank.
  3. Flush the system with clean water.
  4. Fill the system with recommended coolant.
Fuel Filter Cleaning/Replacement Procedure maintenance

⚠ Wash hands after any contact with fuel oil. Dispose of the fuel filter in an approved manner.

Tools: Rags

  1. Close the fuel supply valve.
  2. Loosen the fuel filter by turning it counterclockwise; remove and clean up spilled fuel oil.
  3. Clean the contact surface of the fuel oil filter adapter.
  4. Lightly lubricate the gasket surface of the new fuel filter with fresh fuel oil; thread on until gasket contacts, hand-tighten one-half turn.
  5. Open the fuel supply valve.
  6. Bleed the system.
Fuel System Bleed Procedure maintenance

⚠ Wipe up any spilled diesel fuel. Wash hands after any contact with fuel.

Tools: Rag

  1. Loosen the fuel filter's air vent screw.
  2. Initiate the auto/start sequence until fuel, free of air bubbles, flows from the vent screw.
  3. Tighten the fuel filter's air vent screw.
Fuel System Bleed Procedure (Preferred) maintenance

⚠ To prevent damage to the starter motor, do not crank the engine to prime the fuel system.

  1. Push the Power button on the Advanced Digital Control IId to the ON position.
  2. When run time hours appear, rotate the pushbutton/rotary selector dial until PUSH TO PRIME appears.
  3. Push the pushbutton/rotary selector dial.
  4. Rotate the pushbutton/rotary selector dial to CONFIRM PRIME: Yes.
  5. Push the pushbutton/rotary selector dial to begin the 30-second fuel priming sequence.
  6. Push the control knob to stop the priming procedure before 30 seconds if necessary.
Generator Set Storage Procedure maintenance

⚠ Do not allow coolant mixture to flow into waterways. Use antifreeze capable of withstanding the lowest possible temperatures.

  1. Start and run the generator set until it reaches operating temperature or about 15 minutes.
  2. Stop the generator set.
  3. Change the oil and oil filter.
  4. Close the seacock and remove the hose at the seacock; place the hose in a container of about 3.7-7.5 L (1-2 U.S. gallons) of coolant/antifreeze.
  5. Disconnect the lead (#87) to the low seawater pressure (LWP) switch.
  6. With a container at the exhaust outlet, run the generator set until coolant discharges or the mixture is depleted.
  7. Reconnect the lead (#87) to the low seawater pressure (LWP) switch.
  8. Stop the generator set.
  9. Connect a hose to the seacock; leave the seacock closed.
  10. Check the heat exchanger coolant level and add coolant if necessary.
  11. Clean the exterior and spread a light film of oil or silicon spray over exposed surfaces.
  12. Disconnect and remove the battery; store in a warm, dry location and recharge monthly.
  13. Select a well-ventilated (not humid or dusty) location to store the generator.
  14. Cover the entire unit with a dust cover.
  15. Run the generator set once a month whenever possible.
Impeller Inspection and Replacement Procedure maintenance
  1. Close the seacock.
  2. Remove the seawater pump coverplate.
  3. Remove the impeller.
  4. Inspect the impeller for damaged, cracked, broken, missing or flattened vanes; vanes should be straight and flexible.
  5. Lubricate the impeller with soapy water before installation.
  6. Install the impeller, pushing and rotating in the same direction as engine rotation until seated.
  7. Inspect the coverplate and gasket for corrosion and/or damage; replace as necessary.
  8. Lubricate the gasket with silicon grease and attach the gasket and coverplate.
  9. Open the seacock.
  10. Start the generator set and check for leaks.
  11. Stop the generator set and repair leaks or replace damaged or worn components.
Oil Change Procedure maintenance

⚠ Dispose of all waste materials (engine oil, fuel, filter, etc.) in an environmentally safe manner.

Tools: Oil filter wrench, Oil collection container

  1. Whenever possible, drain the oil while it is still warm.
  2. Place master switch OFF; disconnect power to battery charger; disconnect battery negative (-) lead first.
  3. Remove oil drain hose from retaining clip, remove cap, lower into oil collection container.
  4. Open the oil drain valve on the engine and allow the engine oil to drain completely; close the valve.
  5. Remove the oil filter by rotating it counterclockwise with an oil filter wrench.
  6. Apply a light coat of clean oil to the rubber seal of the new oil filter.
  7. Install the new oil filter following the instructions provided with the filter.
  8. Fill with new oil of the weight, grade, and quantity specified in Section 3.3.
  9. Reconnect the battery, negative (-) lead last; reconnect power to the battery charger.
  10. Start the generator set and check for leaks around the oil filter.
  11. Stop the generator set and tighten the oil filter to stop any leaks.
Seawater Pump Priming maintenance
  1. Close the seacock.
  2. Remove the hose from the seawater-filter outlet.
  3. Fill the hose and seawater pump with clean water.
  4. Reconnect the hose to the water filter outlet.
  5. Open the seacock.
  6. Confirm seawater pump operation on startup as indicated by water discharge from the exhaust outlet.
Siphon Break Inspection maintenance

⚠ Ensure that the siphon break's cap is tight before operating the generator set.

Tools: Mild detergent

  1. Stop the generator set.
  2. Remove the retaining cap and remove the reed valve for inspection.
  3. Use a mild detergent to remove residue and oxidation from the reed valve.
  4. Clear blockage from the reed valve opening.
  5. Replace the siphon break if the reed valve is cracked or the material has hardened or deteriorated.
  6. Install the reed valve into the mounting base with the valve downward.
  7. Install and only finger tighten the retaining cap.
Sound Shield Roof and Door Removal maintenance

⚠ Accidental starting. Disconnect the battery cables before working on the generator set. Remove the negative (-) lead first.

  1. Open the service-side door.
  2. Release the two wing nuts (if equipped) located underneath the roof.
  3. Lift up the roof.
  4. Slide the roof towards the service side of the unit for removal.
  5. Open the front, rear, and non-service side doors as needed.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Voltage reconnection

VoltagePhaseConnectionLeadsNotes
3/8 NPT FemaleFuel Supply Connection
M12x1.75Negative (-) Battery ConnectionThread pitch 1.75 mm
M8x1.25Positive (+) Battery ConnectionThread pitch 1.25 mm

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Aftermarket parts that fit this engine

10

Parts listed by aftermarket suppliers as fitting this engine — leads compiled from supplier catalogs; verify the exact part for your serial number.

Also used in

4
  • Caterpillar 420 — Backhoe Loader
  • Caterpillar 430 — Backhoe Loader
  • Caterpillar 432 — Backhoe Loader
  • Caterpillar 444 — Backhoe Loader

Other equipment known to use this engine, via filter-application cross-reference — useful for sourcing parts even when your exact machine isn't listed elsewhere on this page.

Common questions

What is the displacement of the Caterpillar C3.6?

The Caterpillar C3.6 has a displacement of 3.6 liters.

Which generators use the Caterpillar C3.6 engine?

The Caterpillar C3.6 powers 18 generator set(s), including Kohler 11EFKOZD, Kohler 12EFKOZD, Kohler 13EFKOZD, Kohler 13EKOZD, Kohler 14EKOZD.

What is a common problem with the Caterpillar C3.6 engine?

A commonly reported issue on generators using the Caterpillar C3.6 is: Accidental starting. Fix: Disconnect the battery cables before working on the generator set. Remove the negative (--) lead first when disconnecting the battery. Reconnect the negative (--) lead last when reconnecting the battery..