HomeEnginesCaterpillar 3516B

Caterpillar 3516B Engine

The Caterpillar 3516B is a 69 L 6-cylinder ta engine rated at 1800 rpm, producing up to 1450 kW. It powers generator sets from Caterpillar, including the 3416B, 3500B, 3516 and XQ 2000. It holds 727 L (192.1 gal) of oil and 233.4 L (61.7 gal) of coolant.

Also known as: Caterpillar 3516B

Part of the Caterpillar 3516B engine family — 5 variants share parts & fitment.

69.0 L
Displacement
6
Cylinders
1800 rpm
Rated speed
1450 kW
Gross power

Engine specifications

Oil capacity727.0 L
Coolant capacity233.4 L
Displacement69.0 L
Cylinders6
AspirationTA
Rated speed1800 rpm
Gross power1450 kW

Service intervals

40
ItemActionHoursMonthsNotes
Battery Electrolyte LevelCheck250 hrEvery 250 Service Hours
BeltsInspect250 hrInspect/Adjust/Replace; Every 250 Service Hours
Cooling System Coolant Sample (Level 1)Other250 hrObtain; Every 250 Service Hours
Cooling System Supplemental Coolant Additive (SCA)Test250 hrTest/Add; Every 250 Service Hours
Engine Oil SampleOther250 hrObtain; Every 250 Service Hours
Engine Oil SampleTest250 hrEvery 250 Service Hours - Obtain
Engine Valve LashAdjust4000 hrFirst service — Inspect/Adjust; Initial 250 Service Hours
Fan Drive BearingLubricate250 hrEvery 250 Service Hours
Fuel InjectorAdjust4000 hrFirst service — Inspect/Adjust; Initial 250 Service Hours
Hoses and ClampsInspect250 hrInspect/Replace; Every 250 Service Hours
RadiatorClean250 hrEvery 250 Service Hours
Speed SensorClean250 hrFirst service — Initial 250 Service Hours (Prime Power) - Clean/Inspect
Air ShutoffTest500 hrEvery 500 Service Hours (Prime Power)
Cooling System Coolant Sample (Level 1)Test500 hrEvery 500 Service Hours (Prime Power)
Cooling System Coolant Sample (Level 2)Test500 hrFirst service — Initial 500 Hours for new, refilled and converted systems
Engine Oil and FilterChange500 hrEvery 500 Service Hours - standard sump; deep sump every 1000 hours
Magnetic PickupsClean500 hrFirst service — Clean/Inspect; Initial 500 Service Hours or at first oil change
oilChange500 hr3000 Series service intervals increased to 500 hours as standard (3013C, 3024C, 3054, 3056)
Cooling System Coolant Sample (Level 2)Other1000 hrObtain; Every 1000 Service Hours
EngineClean1000 hrEvery 1000 Service Hours
Engine Crankcase BreatherClean1000 hrEvery 1000 Service Hours
Engine Protective DevicesCheck1000 hrEvery 1000 Service Hours
Engine Protective DevicesTest1000 hrCheck; Every 1000 Service Hours
Fuel System Primary FilterReplace1000 hrEvery 1000 Service Hours - Clean/Inspect/Replace
Fuel System Secondary FilterReplace1000 hrEvery 1000 Service Hours
Generator Winding InsulationTest1000 hrEvery 1000 Service Hours
Rotating RectifierInspect1000 hr12 moEvery 1000 Service Hours or 1 Year - Inspect/Test
Crankshaft Vibration DamperInspect2000 hrEvery 2000 Service Hours
Engine MountsCheck2000 hrEvery 2000 Service Hours
GeneratorOther2000 hr6 moEvery 2000 Service Hours or 6 Months - Dry
Generator Set VibrationTest2000 hrEvery 2000 Service Hours - Test/Record
Stator LeadCheck2000 hr6 moEvery 2000 Service Hours or 6 Months
TurbochargerInspect2000 hrEvery 2000 Service Hours
Cooling System Coolant (DEAC)Change3000 hr36 moEvery 3000 Service Hours or 3 Years
Cooling System Coolant Extender (ELC)Other3000 hr36 moEvery 3000 Service Hours or 3 Years - Add
Air Shutoff DamperCheck6000 hrEvery 6000 Service Hours - Remove/Check
AlternatorInspect6000 hr72 moEvery 6000 Service Hours or 6 Years
Cooling System Coolant (ELC)Change6000 hr72 moEvery 6000 Service Hours or 6 Years
Cooling System Water Temperature RegulatorReplace6000 hr72 moEvery 6000 Service Hours or 6 Years
Prelube PumpInspect6000 hr72 moEvery 6000 Service Hours or 6 Years

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Service specifications

60
TypeItemValueUnitCondition
ClearanceAir shutoff damper plunger distance A (minimum)18.3mm0.72 inch; replace plunger if less
ClearanceCoolant level below bottom of filler pipe13mmno sight gauge
GapAir shutoff damper plunger distance A (replace if less)18.3mm
OtherAir cleaner element cleaning limitsix timesreplace at least once per year regardless
OtherAltitude capability without derate1525m
OtherAltitude capability without derate800m
OtherCoolant Sample (Level 1) interval for Cat DEAC250hours
OtherCooling system cleaner amount (heavy deposits)0.5L per 3.8 to 7.6 L capacity1 pint per 1 to 2 US gal
OtherCooling system cleaner amount (normal deposits)0.5L per 15 L capacity1 pint per 4 US gal
OtherCooling system cleaning duration (heavy deposits)90minutesminimum, coolant at least 82 C (180 F)
OtherCooling system cleaning duration (normal deposits)30minutesminimum, coolant at least 82 C (180 F)
OtherCooling system fill rate maximum19L/min
OtherDamper fluid viscosity degradation limit20percentmajority of applications
OtherDamper fluid viscosity degradation limit (Hasse & Wrede)20percentmajority of applications
OtherDamper operating hours before rebuild/replace (damper without sampling port)20000hours
OtherDamper without sampling port - rebuild/replace interval20000hoursor at major overhaul
OtherFast Acting Cooling System Cleaner amount0.5 L per 15 LLcooling system capacity, normal deposits
OtherFast Acting Cooling System Cleaner amount0.5 L per 3.8 to 7.6 LLcooling system capacity, heavy deposits
OtherHydrosolv cleaner concentration2 to 5percenttemperatures up to 93 C (200 F)
OtherMaximum air pressure at nozzle for cleaning purposes205kPa30 psi
OtherNew drive belt tension recheck after operation30minutesrated rpm
OtherRating condition (diesel 7 L and higher)99 kPa (29.31 in Hg) dry barometer, 25°C (77°F)SAE J1995 inlet air standard
OtherRating condition (diesel up to 6.6 L)100 kPa (29.5 in Hg) total barometric pressure, 1 kPa (.295 in Hg) vapor pressure, 25°C (77°F)ISO/TR14396 inlet air standard
OtherRating condition (gas)100 kPa (29.61 in Hg) and 25°C (77°F)SAE J1349 standard
OtherStarting motor cool-down between cranking periods2minutes
OtherSupplemental coolant additive concentration maximum (conventional coolant)6percent
OtherSupplemental coolant additive concentration maximum (water and SCA)8percent
OtherThread lock cure time minimum before air shutoff use1hour
PressureAir cleaner service indicator restriction (clean/replace)6kPa25 inches of H2O
PressureEngine air cleaner differential pressure (nominal)3kPanormal engine operation
PressureEngine air cleaner maximum differential pressure (replace element)6.2kPa
PressureEngine oil filter differential pressure (nominal)60kPanormal engine operation
PressureEngine oil filter differential pressure (normal)60kPanormal engine operation
PressureEngine oil filter differential pressure (replace elements)103kPaoil filter elements to be replaced
PressureEngine oil pressure during cranking70kPacranking with fuel off
PressureFuel filter differential pressure (nominal)60kPanormal engine operation
PressureFuel filter differential pressure (normal)60kPanormal engine operation
PressureFuel filter differential pressure (replace secondary elements)103kPafuel filter elements to be replaced
PressureMaximum air pressure at nozzle for cleaning205kPa
PressureMaximum air pressure for cleaning (aftercooler core)205kPa30 psi; at nozzle
PressureMaximum air pressure for cleaning (radiator)205kPa30 psi; deadheaded nozzle
PressureMaximum air pressure for cleaning air cleaner element207kPa30 psi
PressureMaximum water pressure for cleaning (aftercooler core)275kPa40 psi
PressureOil pressure required before starting after oil change70kPa10 psi; crank with fuel off, max 30 seconds
PressureUnit injector fuel injection pressure1240bar (18 000 psi)
ResistanceExciter field L1 resistance - 1400 Frame11ohmsapproximation, winding at room temperature
ResistanceExciter field L1 resistance - 1600 Frame10ohmsapproximation, winding at room temperature
ResistanceExciter field L1 resistance - 1800 Frame10.9ohmsapproximation, winding at room temperature
ResistanceExciter rotor L2 resistance - 1600 Frame0.06ohmsapproximation, use milliohmmeter
ResistanceExciter rotor L2 resistance - 1800 Frame0.05ohmsapproximation, use milliohmmeter
ResistanceMain field (rotor) L3 resistance - 1400 Frame0.35ohmsapproximation
ResistanceMain field (rotor) L3 resistance - 1600 Frame0.5ohmsapproximation
ResistanceMain field (rotor) L3 resistance - 1800 Frame0.9ohmsapproximation
ResistanceMain field (rotor) L3 resistance range0.35 to 1.2ohmsmeasured with multimeter
ResistanceMain stator L4 resistanceless than 0.1ohmuse milliohmmeter
ResistancePilot exciter stator L5 resistanceless than 0.1ohmuse milliohmmeter
ResistanceResistance Temperature Detector (RTD) resistance100ohmgenerator bearings / stator windings
ResistanceSpace heaters required when insulation test result below3megohmsor humidity above 75 percent
SpeedFull load speed1800rpmfull load
SpeedLow idle (electric sets, 50 Hz units)80% of full speedapproximately

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Recommended fluids

FluidGradeStandardAmbientCapacityNotes
CoolantCat DEACDiesel; 3,000 Service Hours or Three Years; annual S·O·SSM Level 2 coolant sampling and analysis
CoolantCat DEAC (Diesel Engine Antifreeze/Coolant)Conventional coolant; SCA required; see SEBU6251
CoolantCat ELCDiesel; 12,000 Service Hours or Six Years; add Cat ELC Extender at 6,000 service hours or one half of service life; annual S·O·SSM Level 2 coolant sampling and analysis
CoolantCat ELC (Extended Life Coolant)Add Cat ELC Extender once; do not use conventional SCA with Cat ELC
CoolantCat ELC ExtenderNeeds to be added only once; add per cooling system capacity
CoolantCat NGECNatural Gas; 16,000 Service Hours or Three Years; use interval that occurs first
CoolantCommercial long life / heavy-duty coolant meeting Caterpillar EC-1Caterpillar Engine Coolant Specification -1 (EC-1)Obtain Level 1 coolant sample
CoolantCommercial long life coolant meeting Caterpillar EC-1Caterpillar Engine Coolant Specification -1 (EC-1)
CoolantSupplemental Coolant Additive (SCA)Max 6 percent with conventional coolant; max 8 percent with water and SCA
Engine oilSee Operation and Maintenance Manual, Refill Capacities and Recommendations227.0 L3508B standard sump capacity; oil change interval 500 service hours
Engine oilCat NGEONatural Gas
Engine oilair tool oilbelow 0°CAir starting motor lubricator; temperatures below 0 C (32 F)
Engine oillow sulfated ash oilRequired for U.S. EPA Tier 4 Final, EU Stage IV engines.
Engine oilCat Arctic DEO SYN SAE 0W-30-40°C to 30°CEngine Crankcase; Industrial Engines
Engine oilCat DEO SYN SAE 5W-40-30°C to 50°CEngine Crankcase; Industrial Engines
Engine oilCat DEO SAE 10W-30-18°C to 40°CEngine Crankcase; Industrial Engines
Engine oilCat DEO SAE 15W-40-9°C to 50°CEngine Crankcase; Industrial Engines
Engine oilnondetergent SAE 10Wabove 0°CAir starting motor lubricator; temperatures greater than 0 C (32 F)
FuelUltra Low Sulfur Diesel (ULSD)Contains less than or equal to 15 parts per million sulfur (mg/kg); required for U.S. EPA Tier 4 Final, EU Stage IV engines. B20 biodiesel capability available.
Fuel35° API gravity at 60°F (16°C)LHV 18,390 Btu/lb (42 780 kJ/kg)Fuel at 85°F (29°C) weighing 7.001 lbs/U.S. gal (838.9 g/liter)
FuelNo. 2 fuel3600 engines designed for 80 000 hours on No. 2 fuel; ratings based on API gravity of 35 at 15 C (60 F), LHV of 42 780 kJ/kg used at 29 C (84 F) with a density of 838.9 g/L
GreaseCat Generator Set GreasePart Number 108-8611
GreaseEA6-40°C to 80°CNon-regreasable bearings 311-0843/311-0844
GreaseMobilith SHC220-40°C to 80°C2.8 gRoller bearings 139-0349/139-0350; every 250 service hours
Grease2S-3230 Bearing Lubricant-29°C to 80°C51.2 gGenerator bearings; 59 mL (2 oz); every 2000 service hours or 12 months
GreaseUNIREX N3-29°C to 60°CDo not exceed 60 °C (140 °F) above ambient; some bearings non-regreasable
OtherCaterpillar Fast Acting Cooling System Cleaner0.5 L per 15 LUse only Caterpillar approved cooling system cleaners
OtherHydrosolv 10019.0 LPart number 174-6854; two to five percent concentration
OtherHydrosolv 416519.0 LPart number 1U-5490; two to five percent concentration
OtherSupplemental Coolant Additive (SCA)Do not exceed six percent (conventional coolant) or eight percent (water and SCA)

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Procedures

12
Belts - Adjusting the Alternator Belt adjustment
  1. Remove the drive belt guard.
  2. Loosen mounting bolt (1), adjusting nuts (2) and mounting bolt (3).
  3. Turn adjusting nuts (2) to increase or decrease drive belt tension.
  4. Tighten adjusting nuts (2), mounting bolt (3), and mounting bolt (1).
  5. Reinstall the drive belt guard.
  6. If new belts installed, recheck tension after 30 minutes at rated rpm.
Belts - Inspect/Adjust/Replace adjustment

⚠ Slippage of loose belts can reduce efficiency of driven components

⚠ Too tight belts place unnecessary stress on components

  1. Remove the drive belt guard.
  2. Loosen mounting bolt, adjusting nuts and mounting bolt.
  3. Turn adjusting nuts to increase or decrease drive belt tension.
  4. Tighten adjusting nuts and both mounting bolts to proper torque.
  5. Reinstall the drive belt guard.
  6. If new drive belts are installed, recheck tension after 30 minutes.
Air Shutoff - Test (ADEM II Engine Control Modules) diagnostic

⚠ Check the wiring for the air shutoff switches, and for the solenoids

  1. Do not start the engine; ensure engine control is OFF.
  2. Verify both air shutoff gates latched OPEN and switches connected.
  3. Turn panel power ON; gates should remain open.
  4. Activate EMERGENCY STOP; both gates should close.
  5. Reset; latch only right gate; power ON; right gate should close.
  6. Latch only left gate; power ON; left gate should close.
  7. Operate engine normally; ensure gates remain latched.
Generator Winding Insulation - Test diagnostic

⚠ High voltage can cause electrocution. Discharge instrument leads and generator windings.

Tools: 300-8648 Insulation Testing Gp

  1. Take the generator out of service.
  2. Visually inspect generator for moisture. If moisture exists, dry the unit first.
  3. Inspect installation. Determine equipment that will be tested.
  4. Discharge capacitance of the windings. Disconnect 'T0' from ground.
  5. Disconnect sensing lead wires for regulator and PT leads of load share module.
  6. Connect insulation tester Black lead to ground; RED lead to 'T0'.
  7. Set voltage to rated voltage. Apply voltage; observe readings at 30 and 60 seconds.
  8. Record 60 second reading (correct for temperature), temperature, and humidity.
Aftercooler Core - Inspect/Clean maintenance

⚠ Do not use a high concentration of caustic cleaner

⚠ Do not use high pressure when the fins are cleaned

  1. Remove the core.
  2. Turn the aftercooler core on one side; remove accessible debris.
  3. Back flush the core with cleaner.
  4. Remove the drain plug; steam clean the core; flush the fins.
  5. Wash the core with hot, soapy water.
  6. Flush thoroughly with clean, fresh water until clear.
  7. Dry the core with compressed air opposite to normal flow direction.
  8. Inspect O-rings/seals; pressure test for leaks; install the core.
Batteries - Replace maintenance

⚠ Batteries give off combustible gases which can explode; ensure proper ventilation.

⚠ Always recycle a battery; never discard a battery.

  1. Turn key start switch OFF. Remove key and all electrical loads.
  2. Turn OFF battery charger. Disconnect the charger.
  3. Disconnect NEGATIVE '-' cable from NEGATIVE battery terminal.
  4. Disconnect POSITIVE '+' cable from POSITIVE battery terminal.
  5. Remove the used battery. Install the new battery.
  6. Connect starting motor cable to POSITIVE '+' battery terminal.
  7. Connect ground plane cable to NEGATIVE '-' battery terminal.
Cooling System Coolant (DEAC) - Change maintenance

⚠ Hot coolant can cause serious burns

⚠ Use only cooling system cleaners approved for Caterpillar engines

Tools: 9S-8140 Pressurizing Pump

  1. Stop engine, allow to cool, relieve pressure, remove filler cap.
  2. Open drain valves or remove drain plugs; drain coolant.
  3. Flush cooling system with clean water.
  4. Close drains; fill with water and Fast Acting Cooling System Cleaner.
  5. Operate engine 30 minutes with coolant temperature at least 82 C.
  6. Stop, cool, drain; flush with clean water until clear.
  7. Fill with coolant/antifreeze; do not install filler cap.
  8. Run engine to purge air; check level; install cap.
Cooling System Coolant (ELC) - Change maintenance

⚠ Use only clean water to flush the cooling system when ELC is drained

Tools: 9S-8140 Pressurizing Pump

  1. Stop engine, allow to cool, relieve pressure, remove filler cap.
  2. Open drain valves or remove drain plugs; drain coolant.
  3. Flush the cooling system with clean water.
  4. Fill with clean water; run until 49 to 66 C; drain.
  5. Repeat flush steps until water drains clean.
  6. Fill with Extended Life Coolant; do not install filler cap.
  7. Run engine to purge air; check coolant level.
  8. Inspect filler cap gaskets; install cap; inspect for leaks.
Engine Air Cleaner Element (Dual Element) - Clean/Replace maintenance

⚠ Never run the engine without an air cleaner element installed

⚠ Never service the air cleaner element with the engine running

  1. Remove the cover and the primary air cleaner element.
  2. Discard the secondary element for every three cleanings of the primary element.
  3. Cover the turbocharger air inlet with tape to keep dirt out.
  4. Clean inside of air cleaner cover and body with a clean dry cloth.
  5. Remove tape; install secondary and primary air cleaner elements.
  6. Install the air cleaner cover.
  7. Reset the air cleaner service indicator.
Engine Air Precleaner - Clean maintenance

⚠ In dusty applications, more frequent cleaning is required.

  1. Remove wing nut (1) and cover (2).
  2. Check for accumulation of dirt and debris in body (3). Clean the body, if necessary.
  3. After cleaning the precleaner, install cover (2) and wing nut (1).
Engine Crankcase Breather - Clean maintenance

⚠ Do not attempt to disassemble the breathers.

  1. Loosen clamp (1). Slide the clamp down on tube (2).
  2. Loosen clamps (3). Remove both breathers as a unit.
  3. Remove O-ring seals (4) from valve covers. Inspect; obtain new seals if necessary.
  4. Remove two clamps (6). Remove both breathers (5) from hose tee (7). Inspect tee for cracks.
  5. Turn breathers upside-down. Clean breather elements with clean, nonflammable solvent.
  6. Allow breather elements to dry before installation. Do not disassemble breathers.
  7. Install breathers into tee; tighten clamps to the torque in Service Manual, Specifications.
  8. Coat O-ring seals with clean engine oil; install and tighten clamps.
Engine Oil and Filter - Change maintenance

⚠ Hot oil and components can cause personal injury.

⚠ Parts and covers are under spring pressure.

Tools: Utility knife (inspect used filter)

  1. After operating at normal temperature, STOP the engine. Drain the warm oil.
  2. Open oil drain; after oil has drained, close the oil drain.
  3. Gradually loosen but do not remove bolts (4); pry cover (5) loose to relieve spring pressure.
  4. Remove cover and O-ring seal. Clean cover, seal, and inside of oil filter housing.
  5. Install new oil filter elements. Install new O-ring seal if damaged.
  6. Install cover (5); ensure springs are seated properly.
  7. Fill crankcase through oil filler tube only. Clean and install oil filler cap.
  8. Close fuel supply; crank until oil pressure gauge indicates 70 kPa (10 psi).

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Voltage reconnection

VoltagePhaseConnectionLeadsNotes
6003wye (10 wire)10 wireBrushless SR4B generator; 0.7 pf; voltage regulator optional; space heater and 100 ohm platinum temperature detectors standard

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Parts cataloged across the Caterpillar 3516B family

58
Part #DescriptionCategory
8N6309Air filter outerair_filter
1R-1725Standard Efficiency Fuel Filterfilter
133-5673Fuel/Water Separatorfuel_filter
1R-0749Fuel Secondary - ADVfuel_filter
1R-0750High Efficiency Fuel Filterfuel_filter
1R-0751High Efficiency Fuel Filterfuel_filter
1R-0755High Efficiency Fuel Filterfuel_filter
1R-0756High Efficiency Fuel Filterfuel_filter
1R-0766High Efficiency Fuel Filterfuel_filter
1R0750Filter fuelfuel_filter
1R0755Filter fuelfuel_filter
1R0756Filter fuelfuel_filter
3S3875Filter fuelfuel_filter
RE506428FINAL FUEL FILTERfuel_filter
RE515345FUEL FILTER (3516)fuel_filter
RE527961FUEL FILTERfuel_filter
RE60021FUEL FILTERfuel_filter
10R9951Head Gasketsgasket
1744947Aftercooler and Lines Gasketsgasket
2322507Manifold Gasketsgasket
2322521Turbocharger Gasketsgasket
2342795Injector Seals/Gasketsgasket
1R0741Filter hydraulichydraulic_filter
328-3655Filter hydraulic/transmissionhydraulic_filter
2W9727Water pump impellerimpeller
2322522Reman Injectorsinjector
1R-0716Engine Oiloil_filter
1R-1808Engine Oil - ADVoil_filter
1R0719Filter oiloil_filter
1R0726Filter oiloil_filter
1440725Connecting rodother_service
1743191Reman Cylinder Headsother_service
256-0330Oxidation Catalyst Assembly - Roundother_service
AEHQ5600-01other_service
AEHQ5640-02994F Wheel Loaderother_service
LEDW3153Supersedes LECW7527other_service
LEHW0155-01CATERPILLAR® ENGINE SPECIFICATIONSother_service
PEHJ0271Cat® Emissions Upgrade Kits for Select 3500 Marine Enginesother_service
PEHJ0287Cat® Performance Upgrade Kits for Select 3508, 3512, and 3516 Marine Enginesother_service
XQ1750power moduleother_service
g01030625Illustration 1other_service
g01045431Illustration 3other_service
i01658146Important Safety Informationother_service
i01985375General Informationother_service
i01990626Electronic Control Module (Generator Set)other_service
i02014506Annunciator Moduleother_service
i02014957Resistive Temperature Device Moduleother_service
i02015971Discrete Input/Output Moduleother_service
212-8176Water pumppump
222-5152Water pump repair kitpump
113-8432Front sealseal
4W3864Water pump sealseal
137-03FIRE EXTING PRES SENSOR SHORT HIGHsensor
137-04FIRE EXTING PRES SENSOR SHORT LOWsensor
38-03EXT TANK FUEL LEVEL SENSOR SHORT HIGHsensor
38-04EXT TANK FUEL LEVEL SENSOR SHORT LOWsensor
ESD5526Speed Controllerspeed_controller
248-5513Thermostatthermostat

Parts cataloged across all variants of this engine family — verify the exact part fits your specific variant and serial number before ordering.

Aftermarket parts that fit this engine

60
348-6693 FridayParts $275.56 218-9901 FridayParts $88.10 171-2212 FridayParts $75.99 7N-1961 FridayParts $148.89 2988838 FridayParts $356.60 20R-4050 FridayParts $625.60 591-2386 FridayParts $625.60 398-4747 FridayParts $625.60 375-1478 FridayParts $34.99 353-2833 FridayParts $96.56 147-7975 FridayParts $217.50 7E-0127 FridayParts $212.23 5P-8309 FridayParts $48.90 122-6585 FridayParts $123.56 261-6847 FridayParts $112.35 3B-6552 FridayParts $7.51 245-4621 FridayParts $2956.66 124-5572 KuduParts $50.00 208-9065 FridayParts $272.61 2G-1034 FridayParts $13.66 7T-2798 FridayParts $41.23 9T3370 FridayParts $406.30 4D-2287 FridayParts $39.92 8M-3368 FridayParts $27.20 5T-9796 FridayParts $34.30 171-8708 FridayParts $97.58 4309449 FridayParts $126.00 212-5883 FridayParts $156.66 1B-7709 FridayParts $19.99 8N-6861 FridayParts $309.44 110-6993 FridayParts $309.44 118-9494 FridayParts $309.44 211-7826 FridayParts $309.44 440-0257 FridayParts $109.20 351-8758 SinoCMP $1069.00 133-6350 FridayParts $1301.00 109-4367 FridayParts $179.99 164-2441 FridayParts $120.99 261-6848 FridayParts $159.99 3E-7826 FridayParts $199.59 415-2428 FridayParts $269.59 415-2430 FridayParts $158.99 180-2441 FridayParts $108.80 145-6034 FridayParts $359.99 179-6862 FridayParts $225.99 179-6863 FridayParts $489.99 297-9545 FridayParts $339.89 297-9546 FridayParts $499.99 314-4130 FridayParts $669.89 6V-2305 FridayParts $619.99 9W-6644 FridayParts $370.99 311-7785 FridayParts $58956.50 233-7973 KuduParts $891.00 10R-1264 FridayParts $529.99 2291631 FridayParts $545.30 162-3906 FridayParts $59.98 298-3648 FridayParts $2650.99 4P-6009 FridayParts $45.26 9T-7757 FridayParts $239.56 6E-5650 FridayParts $2159.50

Parts listed by aftermarket suppliers as fitting this engine — leads compiled from supplier catalogs; verify the exact part for your serial number.

Also used in

12
  • Caterpillar 3516B — Engine
  • Caterpillar 5230 — Excavator Tracked
  • Caterpillar 5230B — Excavator Tracked
  • Caterpillar 787B — Dump Truck
  • Caterpillar 789B — Dump Truck
  • Caterpillar 789C — Dump Truck
  • Caterpillar 789D — Dump Truck
  • Caterpillar 793C — Dump Truck
  • Caterpillar 793D — Dump Truck
  • Caterpillar 994F — Loader Wheeled
  • Caterpillar 994G — Loader Wheeled
  • Caterpillar 994K — Loader Wheeled

Other equipment known to use this engine, via filter-application cross-reference — useful for sourcing parts even when your exact machine isn't listed elsewhere on this page.

Common questions

What is the oil capacity of the Caterpillar 3516B?

The Caterpillar 3516B engine has an oil capacity of 727.0 liters.

What is the displacement of the Caterpillar 3516B?

The Caterpillar 3516B has a displacement of 69.0 liters with 6 cylinders.

Which generators use the Caterpillar 3516B engine?

The Caterpillar 3516B powers 4 generator set(s), including Caterpillar 3416B, Caterpillar 3500B, Caterpillar 3516, Caterpillar XQ 2000.