| Clearance | Coolant level below bottom of filler pipe (engines without recovery tank) | within 13 | mm | 0.5 inch |
| Clearance | Water pump leakage considered normal as engine cools | small amount | | water pump seal is lubricated by coolant in the cooling system |
| Other | Alternator and fan belt tension | 535 | N | at center of longest free length |
| Other | Alternator belt deflection | 13 to 19 | mm | 110 N (25 lb) of force applied midway between the pulleys; 0.50 to 0.75 inch |
| Other | Belt tension adjustment threshold | 250 | N | adjust belt to 535 N if below this value |
| Other | Caterpillar Fast Acting Cooling System Cleaner concentration | 0.5 | L per 15 L | 1 pint per 4 US gal of cooling system capacity |
| Other | Chlorine content limit for heat exchanger cleaning water | more than 300 | ppm | water containing more than 300 ppm of chlorine should not be used |
| Other | Cooling system fill rate | no faster than 19 | L per minute | 5 US gal per minute to avoid air locks |
| Other | Gross Input Torque (TH55-E70) | 12 667 | N•m (9350 lb-ft) | |
| Other | Gross Input Torque (TH55-E90) | 12 677 | N•m (9350 lb-ft) | |
| Other | Paper air cleaner element reuse limit | up to six | times | replace at least one time per year regardless of number of cleanings |
| Other | Plate type heat exchanger cleaner concentration | maximum 4 | percent by weight | cleaning solution temperature less than 60°C (140°F) |
| Other | Rating condition (diesel 7 L and higher) | 99 kPa (29.31 in Hg) dry barometer, 25°C (77°F) | | SAE J1995 inlet air standard |
| Other | Rating condition (diesel up to 6.6 L) | 100 kPa (29.5 in Hg) total barometric pressure, 1 kPa (.295 in Hg) vapor pressure, 25°C (77°F) | | ISO/TR14396 inlet air standard |
| Other | Rating condition (gas) | 100 kPa (29.61 in Hg) and 25°C (77°F) | | SAE J1349 standard |
| Other | Solvent contact time with heat exchanger gaskets | not more than half an hour | | natural rubber, butyl rubber and EPDM gaskets swell in these solvents |
| Other | Stall Torque Ratio (TH55-E70) | 2.23 | | |
| Other | Stall Torque Ratio (TH55-E90) | 2.23 | | |
| Other | Supplemental Coolant Additive (SCA) concentration, coolant and SCA | do not exceed six | percent | |
| Other | Supplemental Coolant Additive (SCA) concentration, water and SCA | do not exceed eight | percent | |
| Pressure | Auxiliary water pump differential pressure requiring component inspection | more than 103 | kPa | 15 psi |
| Pressure | Maximum air pressure at nozzle for cleaning | 205 | kPa | |
| Pressure | Maximum air pressure at nozzle for cleaning | less than 205 | kPa | 30 psi |
| Pressure | Maximum air pressure for air cleaner element cleaning | 207 | kPa | |
| Pressure | Maximum air pressure for cleaning purposes | 205 | kPa | |
| Pressure | Maximum air pressure for cleaning purposes (air nozzle deadheaded) | 205 | kPa | air nozzle deadheaded |
| Pressure | Maximum pressure of filtered, dry air for cleaning paper air cleaner elements | 207 | kPa | 30 psi |
| Pressure | Maximum water pressure for cleaning | 275 | kPa | |
| Pressure | Maximum water pressure for cleaning purposes | 275 | kPa | |
| Pressure | Maximum water pressure for rinsing air cleaner element | 275 | kPa | 40 psi; do not use a spray nozzle |
| Pressure | Unit injector fuel injection pressure | 1240 | bar (18 000 psi) | |
| Pressure | WS255 pump plunger load | 238,000 | lb (107,960 kg) | |
| Pressure | WS273XD pump plunger load | 275,000 | lb (124 738 kg) | |
| Pressure | WS305XD pump plunger load | 250,000 | lb (113 398 kg) | |
| Speed | Engine rpm during cooling system purge | 1500 | rpm | |
| Speed | Engine speed for purging air from engine block cavities during coolant fill | 1500 | rpm | run one minute at 1500 rpm; low idle to increase |
| Speed | Maximum Input Speed (TH55-E70/TH55-E90 transmissions) | 1970 | rpm | |
| Speed | Rated Input Speed (TH55-E70/TH55-E90 transmissions) | 1900 | rpm | |
| Temperature | Coolant temperature during DEAC flush | 82 | °C | minimum |
| Temperature | Coolant temperature during ELC flush | 49 to 66 | °C | |
| Temperature | Coolant temperature while cleaning heavily plugged systems | minimum 82 | °C | 180°F; run at low idle minimum 90 minutes |
| Temperature | Coolant temperature while cleaning with Fast Acting Cooling System Cleaner | minimum 82 | °C | 180°F; run at low idle minimum 30 minutes |
| Temperature | Cooling system flush temperature (ELC change) | 49 to 66 | °C | 120 to 150°F |
| Temperature | Ether cylinder storage temperature (maximum) | 49 | °C | |
| Temperature | Hydrosolv liquid cleaner use temperature | up to 93 | °C | 200°F; two to five percent concentration |
| Temperature | Oven drying temperature for paper air cleaner elements | maximum 82 | °C | 160°F |
| Temperature | Paper air cleaner element wash water temperature | maximum 60 | °C | 140°F; soak element six hours |
| Torque | Air cleaner service indicator | 2 | N·m | |
| Torque | Alternator pivot bolt and link bolt | 22 | N·m | |
| Torque | Fuel injection line union nuts | 30 | N·m | |
| Torque | Fuel line nuts | 40 ± 7 | N·m | 30 ± 5 lb ft |
| Torque | Fuel system primary filter housing bolt | 24 ± 4 | N·m | 18 ± 3 lb ft |
| Torque | Fuel system primary filter screw | 8 | N·m | |
| Torque | Oil filter bowl | 25 | N·m | |
| Torque | Oil filter drain plug | 12 | N·m | |