| Clearance | Exhaust hose minimum downgrade (manifold to through-hull outlet) | 1/2 | inch per linear foot (42 mm/m) | no uphill section between manifold and muffler permitted |
| Clearance | Maximum vertical rise of exhaust hose exiting the muffler | 48 | inches (1.2 m) | measured from bottom of muffler to peak |
| Clearance | Minimum vertical distance between engine exhaust manifold outlet and muffler inlet | 12 | inches (305 mm) | |
| Clearance | Minimum vertical drop from exhaust hose peak to through-hull outlet fitting | 12 | inches (305 mm) | |
| Clearance | Pump belt tension (deflection at middle of belt) | 22 pounds (10 kg) finger pressure gives about 0.4 inch (10 mm) deflection | lb (kg) / inch (mm) | genset stopped, belt guard removed |
| Clearance | V-belt deflection | 0.4 inch (10 mm) | inch (mm) | 20 pounds (10 kg) applied mid-span |
| Clearance | Valve Lash (cold) | 0.0071 - 0.0087 | inch (0.18 - 0.22 mm) | cold |
| Injection timing | Fuel injection timing | 15.5 - 17.5 | degrees BTDC | |
| Other | Battery electrolyte specific gravity | 1.260 | specific gravity | at 80 F (27 C); charge if less than 1.215 |
| Other | Battery specific gravity, fully charged | approximately 1.260 | specific gravity | at 80 F (27 C) |
| Other | Compression Ratio | 22:1 | | |
| Other | Frequency regulation, no load to rated load | 5 | percent (± 1.5 Hz @ 50-60 Hz) | |
| Other | Frequency regulation, no load to rated load | 5 percent (1.5 Hz @ 50/60 Hz) | percent (Hz) | no load to rated load |
| Other | Fuel cetane number / sulfur content | not less than 45 cetane; not more than 0.5 percent sulfur by weight | cetane number; percent | No. 2 diesel fuel ASTM 2-D |
| Other | Fuel pump self-priming lift capacity | 4 | ft. (1.2 m) | fuel inlet height above tank |
| Other | Load Bank Resistor resistance | 30 | Ohm ± 10% | |
| Other | Maximum cranking time | 20 seconds, then wait 2 minutes | seconds | starter will overheat if exceeded |
| Other | Minimum compartment air opening (inlet and outlet) | 35 | in2 (225.8 cm2) | |
| Other | Preheat time (control switch in STOP/PREHEAT) | 5 to 20 | seconds | preheat longer than 20 seconds can damage glow plugs |
| Other | Sea water lift capability (water line to pump inlet) | 4 | ft. (1.2 m) | pump impeller must be wet at initial startup |
| Other | Siphon break mounting height above load-waterline | 12 | inches (305 mm) minimum | vertical position required, remote mounting within 5 ft (1.5 m) radius of injection port |
| Other | Torque of high-pressure fuel line fittings at nozzles | see Engine Service Manual (Onan publication 981-0517) | | after bleeding high pressure fuel system |
| Pressure | Compressed air cleaning pressure (cabinet interior) | less than 40 PSI (276 kPa) | PSI (kPa) | |
| Pressure | Cooling system pressure cap rating | 7 psi (48 kPa) | psi (kPa) | |
| Pressure | Engine oil pressure | 28 - 64 psi (194 - 442 kPa) | psi (kPa) | normal operating temperature |
| Pressure | Engine oil pressure (at operating temperature) | 28 to 64 psi (194 to 442 kPa) | psi (kPa) | engine at operating temperature |
| Pressure | Engine oil pressure, normal operating | 35-80 | psi (241-552 kPa) | engine running |
| Pressure | Exhaust back pressure (maximum) | 3.0 | inches (76 mm) of mercury (10 kPa) | check if exhaust run is more than 30 feet (9 m) overall |
| Pressure | Fuel pump static pressure | 3.5 - 6 psi (24 - 41 kPa) | psi (kPa) | measured at pump outlet with 0-15 psi gauge |
| Pressure | Low oil pressure shutdown | 14 | psi (97 kPa) | |
| Pressure | Low oil pressure shutdown set point | 14 psi (97 kPa) | psi (kPa) | shutdown occurs when pressure falls below |
| Pressure | Low oil pressure switch actuation | 14 psi (97 kPa) | psi (kPa) | fault circuit actuated when pressure drops below this value |
| Pressure | Maximum back pressure at injector fuel return line fitting | 15 | psi (103 kPa) | |
| Pressure | Normal engine oil pressure | 28 - 64 | psi (194 - 442 kPa) | normal operating temperature |
| Resistance | Exciter rotor winding resistance | 0.58 - 0.71 | ohms | room temperature |
| Resistance | Exciter stator winding resistance | 13 - 16 | ohms | room temperature |
| Resistance | Main rotor winding resistance (341 mm reference length) | 2.60 - 3.20 | ohms | room temperature |
| Resistance | Main rotor winding resistance (378 mm reference length) | 2.17 - 2.65 | ohms | room temperature |
| Resistance | Main winding resistance, 12-lead three-phase, reference length 341 mm (13.4 in) | 0.36 - 0.44 | ohms | windings at room temperature |
| Resistance | Main winding resistance, 12-lead three-phase, reference length 378 mm (14.9 in) | 0.15 - 0.19 | ohms | windings at room temperature |
| Resistance | Main winding resistance, 4-lead single-phase, reference length 341 mm (13.4 in) | 0.17 - 0.22 | ohms | windings at room temperature |
| Resistance | Main winding resistance, 4-lead single-phase, reference length 378 mm (14.9 in) | 0.09 - 0.12 | ohms | windings at room temperature |
| Resistance | Polarization index | at least 2 | ratio | 10-minute reading divided by 1-minute reading |
| Resistance | Quadrature winding resistance, 12-lead three-phase, reference length 341 mm (13.4 in) | 2.32 - 2.83 | ohms | windings at room temperature |
| Resistance | Quadrature winding resistance, 12-lead three-phase, reference length 378 mm (14.9 in) | 1.83 - 2.23 | ohms | windings at room temperature |
| Resistance | Quadrature winding resistance, 4-lead single-phase, reference length 341 mm (13.4 in) | 1.33 - 1.63 | ohms | windings at room temperature |
| Resistance | Quadrature winding resistance, 4-lead single-phase, reference length 378 mm (14.9 in) | 0.79 - 0.97 | ohms | windings at room temperature |
| Resistance | Winding insulation resistance, in-service set | not less than 1 | megohm | in service |
| Resistance | Winding insulation resistance, new generator | at least 5 | megohms | dry windings |
| Speed | AVR overspeed cutout when AVR set at 50 Hz | approximately 64 | Hz | 60 Hz genset with AVR set at 50 Hz |
| Speed | Engine operating speed | 1,800 | rpm | |
| Speed | Engine operating speed | 1800 | rpm | |
| Speed | Engine speed / frequency rating basis | 1800 | rpm (1500 rpm also listed for 50 Hz air-flow data) | |
| Speed | No-load frequency, 50 Hz setting | 52.5 | Hz | no load |
| Speed | No-load frequency, 60 Hz setting | 63 | Hz | no load |
| Speed | Operating Speed | 1800 | rpm | |
| Speed | Overspeed shutdown setting | 74 Hz at 60 Hz setting; 64 Hz at 50 Hz setting | Hz | AVR monitored |
| Temperature | Coolant temperature | 160 to 195 F (71 to 91 C) | F (C) | depending on load and sea water temperature |
| Temperature | Coolant temperature shutdown | 210 | °F (99°C) | |
| Temperature | Coolant temperature shutdown limit | 210 | °F (99°C) | |