Home›Engines›Kubota D1005

Kubota D1005 Engine

The Kubota D1005 is a 1 L 3-cylinder diesel engine rated at 1800 rpm, producing up to 9.46 kW. It powers generator sets from Cummins/Onan, Generac and Simson-Maxwell, including the MDKAL, MLT3060K, MLT4060 and MLT4060KVLED. It holds 4.25 L (1.1 gal) of oil and 3.78 L (1.0 gal) of coolant.

Also known as: Kubota D1005

Part of the Kubota D1005 engine family — 4 variants share parts & fitment.

1.001 L
Displacement
3
Cylinders
1800 rpm
Rated speed
9 kW
Gross power

Service parts for the D1005

The cheapest captured merchant offer per filter — see the full cross-reference below for every OEM/aftermarket option.

Air intake

1 required
K318182240Air filterfind

Oil system

1 required

Prices captured from merchant listings; some links are affiliate links. Verify against your serial number before ordering.

Engine specifications

Oil capacity4.25 L
Coolant capacity3.78 L
Displacement1.001 L
Cylinders3
AspirationDiesel
Rated speed1800 rpm
Gross power9 kW

Generator sets powered by this engine

6

Shared across brands: Cummins/Onan, Generac, Simson-Maxwell

This engine also powers 2 machine(s) on Power Equipment Info.

How to read your Kubota engine serial & model number →

Common problems

15
  • Oil pressure switch failure
    Fix: Refer to OEM engine operator’s manual to identify corrective action.
  • Oil leaking from engine
    Cause: Visually inspect the engine for leaks.
  • Low oil pressure shutdown
    Cause: Low oil level
    Fix: Verify oil level on dipstick. Add oil, if needed.
  • High coolant temperature shutdown
    Cause: Low coolant level
    Fix: Add coolant if needed. Allow engine to cool, then check coolant level in radiator. Restart engine and check coolant temperature. Stop engine immediately if coolant temperature is 210°F (99°C) or more.
  • Generator output incorrect
    Cause: Check the incoming voltage to the ballast by checking the available voltage on the GFCI receptacle. Incoming voltage should be 120V ±5V.
    Fix: If voltage is incorrect, the engine speed may need to be adjusted or generator may require service.
  • Unit cranks but does not start
    Cause: Low fuel level
    Fix: Check fuel level in tank. Verify fuel pump operation.
  • Unit cranks, but will not start
    Cause: Fuel level low
    Fix: Check fuel level in tank. Verify fuel pump operation.
  • Restricted air filter
    Fix: Inspect air filter for blockage.
  • Mast Lights On But the Light Output is Low
    Cause: Fixture and/or lens is dirty. Lamp worn due to normal use. Damaged or loose electrical connections. Generator output incorrect. Low transformer output
    Fix: Clean reflective surface inside fixture and both inside and outside surface of glass lens. Use mild soap and water to clean lens. Other chemicals may have an adverse effect on the glass. Replace lamp. Check the mast coil cord, mast junction box and mast light connections.
  • Low transformer output
    Fix: The voltage from the transformer should read approximately 400VAC as the light “strikes” (induces an arc), then drop and slowly rise back up to stabilize at 240–260VAC. On hard wired models, remove the mast junction box cover and insert the wire probes into the connector blocks for the light and ground. If proper voltage is not achieved, perform capacitor check to determine if the capacitor or coil needs to be replaced.
  • Leakage in coolant hoses, engine block, or water pump
    Fix: Inspect
  • Blockage in radiator
    Fix: Inspect radiator shroud and ducting for blockage and remove any foreign matter.
  • Water Sedimenter - Drain Water
    Fix: Drain Water From Water Sediment Separator
  • Transformer output low
    Fix: Verify voltage from transformer: When a bulb strikes (induces an arc), transformer voltage should be approximately 400 VAC. Next, voltage should drop, slowly rise, then stabilize at 240–260 VAC. On hard-wired models, remove mast junction box cover and insert wire probes into the connector blocks of the light and ground. If correct voltage is not achieved, check the capacitor to determine if capacitor or coil must be replaced.
  • Overspeed or Underspeed Shutdown
    Cause: Frequency setting incorrect
    Fix: Disconnect all loads and restart unit. Read frequency (Hz) in the LCD window on controller. Frequency should read 60 Hz. If frequency is above 60 Hz, engine speed will need to be adjusted. Refer to the engine operator’s manual for throttle adjustment information.

Compiled from service & troubleshooting documentation across every generator set that uses the Kubota D1005.

Maintenance schedule

ItemSpecCapacityPart #Interval
Air filter—
Fuel filterLubricate new element and gasket; fill element with clean diesel fuel; hand tighten—500 hr
Oil filterFull flow, spin-on type76650254301000 hr Amazon eBay $22.12 PartsGeek $7.98 NAPA $13.30
Battery12 volts, minimum CCA 360 amps (MDKAL) or 500 amps (MDKAA/MDKAB); specific gravity of fully charged battery approx. 1.260 at 80 F (27 C)—100 hr
BeltDeflection 0.4 inch (10 mm) at 20 pounds (10 kg) applied mid-span—800 hr
CoolantEthylene or propylene glycol antifreeze, fully formulated with rust inhibitors and coolant stabilizers, no stop-leak; 50/50 mixture good for -34 F (-37 C)3.78—800 hr
Coolant filter—
OilAPI Class CG-4, CF-4, CF or better; SAE 15W-40 multi-grade recommended for year-round use4.25—100 hr
Spark plug—

Pooled from every document that names this exact engine — confirm the interval and part number against your unit's serial number.

Service intervals

40
ItemActionHoursMonthsNotes
Light tower winchInspectCheck daily for proper operation
Radiator finsInspectInspect daily for debris
Battery conditionInspect1 hrMitsubishi schedule
Coolant levelCheck8 hrKeep recovery tank between COLD and HOT
Electrical connectionsCheck8 hrDaily or before use
Exhaust systemCheck8 hrEvery time genset is started and every 8 hours if run continuously
Fuel levelCheck8 hrDaily or before use
Generator set (exhaust, fuel, DC electrical and mechanical inspection)Inspect8 hrInspect daily or after every eight hours of operation, whichever comes first.
GensetInspect8 hrCheck for oil, fuel, coolant and exhaust system leaks; every time started or every 8 hrs if run continuously
Oil levelCheck8 hrKeep between FULL and ADD on dipstick
Tire pressureCheck8 hrDaily or before use
Engine oil and filterChange35 hrFirst service — Table 4 footnote 2 / Break-In Procedure: Perform after first 35 hours of operation on new genset (drain crankcase and refill with new oil).
Oil & Oil FilterChange200 hr6 moFirst service — After first 35 hours (break-in)
Oil and oil filterChange100 hr1 moFirst service — After first 35 hours (engine break-in)
Air cleanerCheck250 hrFirst service — Mitsubishi maintenance schedule
Bolts and nuts on engineAdjust50 hrFirst service — Mitsubishi: retighten after initial 50 hours.
Engine bolts and nutsAdjust50 hrFirst service — Mitsubishi after first 50 hours
Engine oil and oil filterChange50 hrFirst service — Change after the initial 50 hours of operation, then at the appropriate regularly scheduled interval thereafter
Engine oil and oil filterReplace250 hrFirst service — Perform after initial 50 hours, then on regularly scheduled interval.
Fuel Tank - WaterDrain50 hrMLT3060MV Mitsubishi schedule
Replace engine oil and oil filterChange50 hrFirst service — Mitsubishi engine, after initial 50 hours, then at regular interval thereafter
Water SeparatorDrain50 hrMLT3060KV / MLT3080KV Kubota schedule
BatteryCheck100 hr1 moSee battery manufacturer's recommendations
Fan Belt TightnessCheck100 hrMLT3060KV / MLT3080KV Kubota schedule
Fuel FilterClean100 hrMLT3060KV / MLT3080KV Kubota schedule
GensetClean100 hr1 moDo not clean while running
Intake Air LineCheck100 hrMLT3060KV / MLT3080KV Kubota schedule
V-belt tensionCheck100 hr1 moCheck for slippage
Water and sediment in fuel filterDrain100 hr1 moAbout 1/2 cup (120 ml)
Water in FuelDrain100 hr1 mo
Engine OilChange200 hrFirst service — MLT3060KV / MLT3080KV Kubota schedule - * change after initial 50 hours, then at appropriate interval
Fuel Filter CartridgeReplace200 hrMLT3060KV / MLT3080KV Kubota schedule
Fuel Pipes And Clamp BandsCheck200 hrMLT3060KV / MLT3080KV Kubota schedule
Fuel Tank SedimentClean200 hrMLT3060KV / MLT3080KV Kubota schedule - remove sediment
Oil Filter CartridgeReplace200 hrFirst service — MLT3060KV / MLT3080KV Kubota schedule - * after initial 50 hours
Radiator Hoses And Clamp BandsCheck200 hrMLT3060KV / MLT3080KV Kubota schedule
Siphon breakCheck200 hr6 moCheck plunger free movement or vent hose connections
Water SeparatorClean200 hrMLT3060KV / MLT3080KV Kubota schedule
Zinc AnodeChange500 hr12 mo
Engine Starting BatteryInspect250 hrMLT3060MV Mitsubishi schedule

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Service specifications

60
TypeItemValueUnitCondition
ClearanceExhaust hose minimum downgrade (manifold to through-hull outlet)1/2inch per linear foot (42 mm/m)no uphill section between manifold and muffler permitted
ClearanceMaximum vertical rise of exhaust hose exiting the muffler48inches (1.2 m)measured from bottom of muffler to peak
ClearanceMinimum vertical distance between engine exhaust manifold outlet and muffler inlet12inches (305 mm)
ClearanceMinimum vertical drop from exhaust hose peak to through-hull outlet fitting12inches (305 mm)
ClearancePump belt tension (deflection at middle of belt)22 pounds (10 kg) finger pressure gives about 0.4 inch (10 mm) deflectionlb (kg) / inch (mm)genset stopped, belt guard removed
ClearanceV-belt deflection0.4 inch (10 mm)inch (mm)20 pounds (10 kg) applied mid-span
ClearanceValve Lash (cold)0.0071 - 0.0087inch (0.18 - 0.22 mm)cold
Injection timingFuel injection timing15.5 - 17.5degrees BTDC
OtherBattery electrolyte specific gravity1.260specific gravityat 80 F (27 C); charge if less than 1.215
OtherBattery specific gravity, fully chargedapproximately 1.260specific gravityat 80 F (27 C)
OtherCompression Ratio22:1
OtherFrequency regulation, no load to rated load5percent (± 1.5 Hz @ 50-60 Hz)
OtherFrequency regulation, no load to rated load5 percent (1.5 Hz @ 50/60 Hz)percent (Hz)no load to rated load
OtherFuel cetane number / sulfur contentnot less than 45 cetane; not more than 0.5 percent sulfur by weightcetane number; percentNo. 2 diesel fuel ASTM 2-D
OtherFuel pump self-priming lift capacity4ft. (1.2 m)fuel inlet height above tank
OtherLoad Bank Resistor resistance30Ohm ± 10%
OtherMaximum cranking time20 seconds, then wait 2 minutessecondsstarter will overheat if exceeded
OtherMinimum compartment air opening (inlet and outlet)35in2 (225.8 cm2)
OtherPreheat time (control switch in STOP/PREHEAT)5 to 20secondspreheat longer than 20 seconds can damage glow plugs
OtherSea water lift capability (water line to pump inlet)4ft. (1.2 m)pump impeller must be wet at initial startup
OtherSiphon break mounting height above load-waterline12inches (305 mm) minimumvertical position required, remote mounting within 5 ft (1.5 m) radius of injection port
OtherTorque of high-pressure fuel line fittings at nozzlessee Engine Service Manual (Onan publication 981-0517)after bleeding high pressure fuel system
PressureCompressed air cleaning pressure (cabinet interior)less than 40 PSI (276 kPa)PSI (kPa)
PressureCooling system pressure cap rating7 psi (48 kPa)psi (kPa)
PressureEngine oil pressure28 - 64 psi (194 - 442 kPa)psi (kPa)normal operating temperature
PressureEngine oil pressure (at operating temperature)28 to 64 psi (194 to 442 kPa)psi (kPa)engine at operating temperature
PressureEngine oil pressure, normal operating35-80psi (241-552 kPa)engine running
PressureExhaust back pressure (maximum)3.0inches (76 mm) of mercury (10 kPa)check if exhaust run is more than 30 feet (9 m) overall
PressureFuel pump static pressure3.5 - 6 psi (24 - 41 kPa)psi (kPa)measured at pump outlet with 0-15 psi gauge
PressureLow oil pressure shutdown14psi (97 kPa)
PressureLow oil pressure shutdown set point14 psi (97 kPa)psi (kPa)shutdown occurs when pressure falls below
PressureLow oil pressure switch actuation14 psi (97 kPa)psi (kPa)fault circuit actuated when pressure drops below this value
PressureMaximum back pressure at injector fuel return line fitting15psi (103 kPa)
PressureNormal engine oil pressure28 - 64psi (194 - 442 kPa)normal operating temperature
ResistanceExciter rotor winding resistance0.58 - 0.71ohmsroom temperature
ResistanceExciter stator winding resistance13 - 16ohmsroom temperature
ResistanceMain rotor winding resistance (341 mm reference length)2.60 - 3.20ohmsroom temperature
ResistanceMain rotor winding resistance (378 mm reference length)2.17 - 2.65ohmsroom temperature
ResistanceMain winding resistance, 12-lead three-phase, reference length 341 mm (13.4 in)0.36 - 0.44ohmswindings at room temperature
ResistanceMain winding resistance, 12-lead three-phase, reference length 378 mm (14.9 in)0.15 - 0.19ohmswindings at room temperature
ResistanceMain winding resistance, 4-lead single-phase, reference length 341 mm (13.4 in)0.17 - 0.22ohmswindings at room temperature
ResistanceMain winding resistance, 4-lead single-phase, reference length 378 mm (14.9 in)0.09 - 0.12ohmswindings at room temperature
ResistancePolarization indexat least 2ratio10-minute reading divided by 1-minute reading
ResistanceQuadrature winding resistance, 12-lead three-phase, reference length 341 mm (13.4 in)2.32 - 2.83ohmswindings at room temperature
ResistanceQuadrature winding resistance, 12-lead three-phase, reference length 378 mm (14.9 in)1.83 - 2.23ohmswindings at room temperature
ResistanceQuadrature winding resistance, 4-lead single-phase, reference length 341 mm (13.4 in)1.33 - 1.63ohmswindings at room temperature
ResistanceQuadrature winding resistance, 4-lead single-phase, reference length 378 mm (14.9 in)0.79 - 0.97ohmswindings at room temperature
ResistanceWinding insulation resistance, in-service setnot less than 1megohmin service
ResistanceWinding insulation resistance, new generatorat least 5megohmsdry windings
SpeedAVR overspeed cutout when AVR set at 50 Hzapproximately 64Hz60 Hz genset with AVR set at 50 Hz
SpeedEngine operating speed1,800rpm
SpeedEngine operating speed1800rpm
SpeedEngine speed / frequency rating basis1800rpm (1500 rpm also listed for 50 Hz air-flow data)
SpeedNo-load frequency, 50 Hz setting52.5Hzno load
SpeedNo-load frequency, 60 Hz setting63Hzno load
SpeedOperating Speed1800rpm
SpeedOverspeed shutdown setting74 Hz at 60 Hz setting; 64 Hz at 50 Hz settingHzAVR monitored
TemperatureCoolant temperature160 to 195 F (71 to 91 C)F (C)depending on load and sea water temperature
TemperatureCoolant temperature shutdown210°F (99°C)
TemperatureCoolant temperature shutdown limit210°F (99°C)

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Recommended fluids

FluidGradeStandardAmbientCapacityNotes
Coolant50% glycol, 50% waterbelow 49°CStandard mixture; 60/40 and heated options available for cold weather
Coolant50% glycol, 50% water or 60% glycol, 40% waterbelow 49°CLiquid cooled engines with standard 50/50 mixture or optional cold-weather 60/40 configuration
Coolant50-50 mixture of coolant (ethylene glycol or propylene glycol) and distilled water3.78 L (4 qt)Do not exceed a 50-50 mixture; contains rust inhibitors
Coolant50/50 glycol/water or 60/40below 49°CLiquid cooled diesel engines
Coolant50/50 mixture of ethylene glycol anti-freeze and waterReliable brand anti-freeze containing rust and corrosion inhibitor; no stop-leak additive; use distilled or soft waterabove -37°C3.78 l4 qt (3.78 L). A 50/50 mixture provides freeze protection to -34 F (-37 C). Do not deviate from a 50/50 mixture.
Coolant50/50 mixture of water and ethylene glycol (ethylene or propylene glycol antifreeze with rust inhibitors and coolant stabilizers; no stop-leak)above -37°C50/50 mixture good for -34 F (-37 C); coolant capacity 4.2 quart (4.0 liter) MDKAL, 5.3 quart (5.0 liter) MDKAA/MDKAB; use distilled water
Coolant40% water / 60% antifreezeabove -36°CFreezing point -34°F (-36°C); maximum freeze protection is 60% antifreeze
Coolant50% water / 50% antifreezeabove -24°CFreezing point -12°F (-24°C); mix demineralized/distilled water with coolant, not hard water
Coolant50/50 ethylene or propylene glycol antifreeze and waterabove 37°CGood for -34F (-37C); fully formulated with rust inhibitors, no stop-leak additives
Engine oilSAE 0W-20 Syntheticbelow -18°CFor use below -0°F / -18°C
Engine oilSAE 10WFrom engine oil viscosity chart decal
Engine oilSAE 15W-40From engine oil viscosity chart decal
Engine oilSAE 15W-40 (year-round)API CG-4, CF-4, CF or betterSee viscosity grade chart vs ambient temperature
Engine oilSAE 15W-40 multi-grade recommended for year-round useAPI Class CG-4, CF-4, CF or betterChoose viscosity grade per Figure 2 ambient temperature chart; capacities: MDKAL Spec A 4.5 quart (4.3 liter), MDKAL Spec B 4.2 quart (4.0 liter), MDKAA/MDKAB 4.5 quart (4.3 liter)
Engine oilSAE 30WFrom engine oil viscosity chart decal
Engine oilSAE 40WFrom engine oil viscosity chart decal
Engine oilSAE viscosity per Table 1 (Oil Viscosity vs. Temperature); select viscosity right for the lowest expected ambient temperatureAPI CG-4, CF-4, CD/SG or CE/SG; do not use synthetic or non-detergent oil-34°C to 48°C4.25 l4.5 qt (4.25 L) including filter. Table 1 covers -30 F to 120 F (-34 C to 49 C) anticipated ambient temperature. If adding oil between changes use the same brand.
FuelASTM 2-D (No. 2 Diesel) or ASTM 1-D (No. 1 Diesel), minimum Cetane number 45Low sulfur content fuel with a cloud point at least 10 degrees below the lowest expected fuel temperaturebelow 0°CNo. 2 diesel gives best economy and performance under most conditions. Use No. 1 diesel when ambient temperatures are below 32 F (0 C) and during long periods of light engine load. Engine is certified to operate on diesel fuel.
FuelDiesel33.8 gal (L)Fuel Tank—Total 33.8 gal (128 L); usable 33.6 gal (127 L)
FuelNo. 2 diesel (ASTM 2-D), Cetane 45 min, sulfur max 0.5% by weightASTM 2-DUse fuel with cloud point at least 10 degrees below lowest expected fuel temperature in cold climates
FuelNo. 2 diesel fuelBasis for fuel consumption data
FuelNo. 2 diesel fuel (ASTM 2-D)ASTM 2-DCetane number not less than 45; sulfur not more than 0.5 percent by weight; cloud point at least 10 degrees below lowest expected fuel temperature
FuelNo. 2D diesel (above freezing) / No. 1D diesel (at or below freezing); climatized 1D/2D mix also usable in some areasUltra-low-sulfur diesel onlyDo NOT use home heating oil or bio-diesel fuel
FuelUltra-low-sulfur diesel No. 1D or No. 2DNo. 1D when at or below freezing; No. 2D when above freezing; climatized fuel acceptable
FuelUltra-low-sulfur diesel; No. 1D below freezing, No. 2D above freezing (climatized 1D/2D blend acceptable in some areas)216.0 LDO NOT use home heating oil or bio-diesel fuel
GreaseHigh quality grease for wheel bearingsUse high quality grease made specifically for lubrication of wheel bearings.
OtherAutomotive grease / lightweight oilFor jack maintenance: automotive grease for internal gearing; lightweight oil for handle unit and caster axle.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Procedures

12
Adjusting V-Belt Tension adjustment

⚠ Accidental starting can cause severe personal injury or death.

  1. Disconnect negative battery cable(s) and remove belt guard or sound shield door.
  2. Loosen alternator pivot bolt first, then adjusting bracket bolt on top.
  3. Pivot alternator outwards to tighten belt; hold tension and tighten bracket bolt.
  4. Apply 20 pounds (10 kg) mid-span and measure deflection 0.4 inch (10 mm).
  5. Tighten alternator bolts when tension is correct.
  6. Secure belt guard or sound shield door and reconnect battery cables (negative last).
Adjusting Voltage (AVR) adjustment

⚠ HAZARDOUS VOLTAGE: touching uninsulated live parts can cause severe personal injury or death.

Tools: Insulated tools

  1. Disconnect all generator loads.
  2. Check 50/60 Hz selector switch position and change if necessary.
  3. Start genset and turn voltage adjusting pot to obtain rated output voltage.
  4. Check and readjust frequency.
  5. Readjust voltage if frequency was changed.
Pump Belt Adjustment adjustment

⚠ Accidental starting of the generator set can cause severe personal injury or death; stop the set and disconnect battery cables before maintenance.

⚠ Operation with too much tension on the pump belt may cause reduced belt life; do not overtighten.

  1. Disable the genset by removing the battery cables, negative (-) cable first.
  2. Open the genset service door; on sets without sound shields remove the belt guard.
  3. Loosen the bottom pivot bolt on the alternator.
  4. Loosen the bolt that passes through the long slot in the alternator mounting bracket.
  5. Slide the alternator until the tension is right.
  6. Do not operate the genset without the belt guard in place.
Voltage Adjustment Procedure (Set Not Running) adjustment

⚠ High voltages within the control cabinet can cause severe personal injury or death.

Tools: non-conductive trimpot adjustment tool

  1. Stop the generator set.
  2. Open the control box.
  3. Adjust the trimmer pot a small increment up or down as needed.
  4. Close the control box, start the set and check output voltage.
  5. Repeat starting/stopping and adjusting until output voltage is correct.
Voltage Adjustment Procedure (Set Running) adjustment

⚠ Lethal voltages are present inside the control box.

⚠ Do not wear jewelry or damp clothing; stand on a dry wooden platform or rubber mat.

Tools: voltmeter, non-conductive screwdriver or trimpot adjustment tool

  1. Connect a voltmeter to the set output.
  2. Start the set.
  3. Adjust the trimmer pot to the desired voltage.
Flashing the Field diagnostic

Tools: AVR/generator test adapter, 6 volt dry cell battery

  1. Disconnect P1/J1 inside the control box.
  2. Connect test adapter and 6 volt dry cell battery for a few seconds.
  3. Connect B+ to F1 (P1-8) and B- to F2 (P1-1).
  4. Reconnect P1/J1.
  5. See Troubleshooting if flashing the field does not restore voltage.
Test the PAS diagnostic
  1. Pull the T-handle (valve must be open before testing) OR press the emergency stop button
  2. Confirm valve closed by verifying knob rotated perpendicular to pipe centerline
Testing AVR vs Generator diagnostic

⚠ HAZARDOUS VOLTAGE: use insulated tools and dry clothing.

Tools: AVR/generator test adapter, 6 volt dry cell battery

  1. Disconnect all generator loads.
  2. Disconnect P1/J1 and connect test adapter and 6 volt dry cell battery.
  3. Start genset and close terminal K4-5 to ground to keep it running.
  4. Measure voltage across test terminals.
  5. If AVR connections good and output 100-140 VAC across Q1-S2 and 130-150 VAC across Q1-Q2, replace AVR.
Fuel System Test installation

⚠ Fuel leakage presents fire and explosion hazards.

  1. After installation, test the fuel system for tightness per USCG specification 33CFR183.542.
  2. Find and correct any leak before putting the fuel system into service.
Installing Coolant Recovery Tank installation
  1. Use the bracket as a template to locate mounting holes.
  2. Allow at least 2 inches (51 mm) from tank top to any upper structure.
  3. Use hose from kit between engine overflow and tank connector.
  4. Route drain tube end to the drip pan to avoid coolant spills to bilge.
  5. Locate tank so hose is pitched slightly downward.
Light Tower Set Up installation

⚠ The mast extends up to 25 ft (7.6 m). Make sure area above the unit is open and clear of overhead wires and obstructions.

  1. For maximum light coverage, locate the unit at ground level or higher than the area being illuminated.
  2. Place the unit on firm, relatively flat ground, then block the wheels to keep it from moving.
  3. Pull the tongue jack locking pin, rotate the jack 90 degrees, replace the pin and raise the trailer tongue off the towing vehicle.
  4. Connect a good earthen ground to the grounding stud on the frame near the trailer tongue.
  5. Pull each outrigger out until the spring loaded locking pin snaps into place; rotate jacks 90 degrees pad down.
  6. Pull the rear jack locking pin and rotate 90 degrees; level all four jacks until firmly in contact with the ground.
  7. Before raising the mast, adjust lamps using the wing nuts on the trunnion, aim, then tighten hardware.
Light Tower Setup installation

⚠ Verify area above unit is clear of overhead wires and obstructions.

⚠ Do not set up the unit if high winds are expected.

  1. Position unit at ground level or higher than the area to be illuminated.
  2. Place unit on firm, relatively flat ground (less than 5° slope); block the wheels.
  3. Pull tongue jack locking pin, rotate jack 90°, install pin, raise trailer tongue.
  4. Ground the unit per NEC, state, and local regulations.
  5. Pull outrigger locking pins, extend outriggers until spring loaded pin snaps; rotate jacks down.
  6. Pull rear jack locking pin and rotate 90° until pin snaps into place.
  7. Adjust all four jacks clockwise until pads firmly contact the ground.
  8. Adjust lamps: loosen trunnion wing nuts, aim, then tighten hardware.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Voltage reconnection

VoltagePhaseConnectionLeadsNotes
110/120 VAC1Load leads connected to the circuit breakers in the control box; output taken from two generator windingsL1, L2, L3 (see Figure 8-9 and schematic 612-6713)Load should be balanced across the windings; full load from one winding can cause poor voltage regulation and damage
120/2401AC distributionFrom generator to main circuit breaker (40A) to lights and auxiliary outletsVoltage regulation: Capacitor +/-6%
220/240 VAC1Load leads connected to the circuit breakers in the control box; output taken from two generator windingsL1, L2, L3 (see Figure 8-9 and schematic 612-6713)Generator is 4-wire reconnectible (1-phase) or 12-wire reconnectible (3-phase)

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Parts cataloged across the Kubota D1005 family

27
Part #DescriptionCategory
185-6934V-BeltBelt
149-2106Fuel FilterFuel filter
300-1500Fuel FilterFuel filter
M1679-2TWO F U E L LINES IN TANK FITTINGFuel line
185-5421Plug, GlowGlow plug
185-7268Glow Plug (24 Volt)Glow plug
132-0375Sea Water Pump Impeller kit w/cover & gasketImpeller
132-0379Sea Water Pump ImpellerImpeller
65004SIDE LIGHTLight
65011SIDE LIGHTLight
65078SIDE LIGHTLight
65381SIDE LIGHTLight
185-5835Oil FilterOil filter
324-1491Oil FilterOil filter
100-3478-02Cruise KitService part / kit
10222Plug, 3 wireService part / kit
130-4434Zinc PencilService part / kit
13498SERVICE LOGService part / kit
185-6721Element, BreatherService part / kit
65003Coil InsulatorService part / kit
65012TRAILER PLUGService part / kit
CS1312-1CROSS-SECTION VIEW HULL STRAINER SEA COCK RECOMMENDED WATER STRAINER OR FILTER FLUSH THROUGH-HULL FITTING TO GENSETService part / kit
KB03MAN2Kubota Workshop ManualService part / kit
W10441170D1005-E3B, D1105-E3B, D1105-T-E3BService part / kit
324-1542Fuel Injection PumpPump
612-6673Water PumpPump
323-1544ThermostatThermostat

Parts cataloged across all variants of this engine family — verify the exact part fits your specific variant and serial number before ordering.

Aftermarket parts that fit this engine

60
16285-52032 Amazon eBay KuduParts $20.59 FridayParts $25.89 SinoCMP $79.00 RTV1140 FridayParts $11.00 16251-73034 Amazon eBay $45.00 FridayParts $42.60 16251-73032 FridayParts $42.60 ZD331 FridayParts $9.90 69mm FridayParts $46.99 16241-73034 FridayParts $46.99 SinoCMP $109.00 16251-73030 FridayParts $42.60 17208-60010 FridayParts $54.30 17208-60015 SinoCMP $49.00 FridayParts $54.30 17208-60016 FridayParts $54.30 17208-60017 FridayParts $54.30 60mm FridayParts $12.94 15521-23530 Amazon eBay FridayParts $68.25 19202-23540 Amazon eBay $34.99 FridayParts $68.25 6A320-59210 FridayParts $98.54 LRS02300 FridayParts $98.54 3Pcs FridayParts $9.90 SinoCMP $36.00 6687911 FridayParts $49.91 6687909 FridayParts $49.91 16032-53000 Amazon eBay SinoCMP $45.00 FridayParts $49.92 16032-53001 FridayParts $49.92 16032-53900 Amazon eBay FridayParts $49.93 6672429 FridayParts $44.48 6680278 FridayParts $44.48 6667453 FridayParts $99.99 6687906 FridayParts $50.58 6674172 KuduParts $14.00 FridayParts $17.75 16604-52030 FridayParts $34.65 16851-52030 FridayParts $18.95 R1401-51352 FridayParts $18.95 R1401-51350 FridayParts $18.85 16032-53902 SinoCMP $45.00 FridayParts $66.00 1G677-53900 FridayParts $89.90 1G677-53902 FridayParts $89.90 1G677-53903 SinoCMP $75.00 FridayParts $89.90 RA211-51280 Amazon eBay KuduParts $9.00 FridayParts $10.99 6969775 FridayParts $10.20 6652576 FridayParts $10.20 17213-12310 Amazon eBay $131.03 FridayParts $199.99 17213-12312 FridayParts $199.99 1E013-63590 FridayParts $20.51 183827 FridayParts $20.51 722D FridayParts $20.51 930D2 FridayParts $20.51 16271-43560 Amazon eBay $18.89 NAPA $16.83 KuduParts $24.00 FridayParts $26.17 1G065-53002 FridayParts $68.99 1G065-53900 FridayParts $68.99 SinoCMP $79.00 1G065-53902 FridayParts $68.99 16261-53001 FridayParts $99.99 16261-53011 FridayParts $99.99 16032-51013 SinoCMP $369.00 FridayParts $499.01 16261-42502 Amazon eBay $12.00 KuduParts $21.00 FridayParts $23.09 16241-35070 Amazon eBay $89.01 FridayParts $102.95 15841-32431 Amazon eBay $17.99 PartsGeek $10.97 FridayParts $20.00 16241-65511 FridayParts $15.99 16241-65510 FridayParts $15.99 16265-12312 FridayParts $99.99 1G700-12310 FridayParts $95.50 SinoCMP $169.00 1K591-12310 FridayParts $95.50

Parts listed by aftermarket suppliers as fitting this engine — leads compiled from supplier catalogs; verify the exact part for your serial number.

Filters for this engine

  • Air filter: Kubota K318182240 Kubota K318182250 Donaldson P778979 Donaldson P780018 Wix 49978 Wix 49968
  • Oil filter: Kubota 7665025430 Donaldson P550162 Wix 51334 Ac Delco X45 Baldwin B179

Cross-referenced via Donaldson + OEM/engine-maker interchange — options to verify against your serial number, not confirmed for every exact variant.

Also used in

12
  • Bobcat 463 — Skid Steer Loader
  • Bobcat S300 — Skid Steer Loader
  • Bobcat S70 — Skid Steer Loader
  • Kubota B21 — Tractor
  • Kubota B2100 — Tractor
  • Kubota B2100DT — Tractor
  • Kubota B2100HST-D — Tractor
  • Kubota B2100HST-DB — Tractor
  • Kubota BX2660 — Tractor
  • Kubota BX2670 — Tractor
  • Kubota F2260-R — Mower
  • Kubota F2560E — Mower

Other equipment known to use this engine, via filter-application cross-reference — useful for sourcing parts even when your exact machine isn't listed elsewhere on this page.

Common questions

What is the oil capacity of the Kubota D1005?

The Kubota D1005 engine has an oil capacity of 4.25 liters.

What is the displacement of the Kubota D1005?

The Kubota D1005 has a displacement of 1.001 liters with 3 cylinders.

Which generators use the Kubota D1005 engine?

The Kubota D1005 powers 6 generator set(s), including Cummins/Onan MDKAL, Generac MLT3060K, Generac MLT4060, Generac MLT4060KVLED, Generac MLT6.

What oil filter does the Kubota D1005 use?

The Kubota D1005 uses oil filter part numbers Kubota 7665025430, Donaldson P550162, Wix 51334.

What air filter does the Kubota D1005 use?

The Kubota D1005 uses air filter part numbers Kubota K318182240, Kubota K318182250, Donaldson P778979.

How often should you change the oil in the Kubota D1005?

The Kubota D1005 oil change interval is every 100 hours.

What is a common problem with the Kubota D1005 engine?

A commonly reported issue on generators using the Kubota D1005 is: Oil pressure switch failure. Fix: Refer to OEM engine operator’s manual to identify corrective action..