Home›Engines›Deutz F3M 2011 F

Deutz F3M 2011 F Engine

The Deutz F3M 2011 F is a 2.33 L natural engine rated at 1500 rpm. It powers generator sets from Atlas Copco, including the QAX 20 Dd. It holds 5.5 L (1.5 gal) of oil and 8 L (2.1 gal) of coolant.

Also known as: DEUTZ F3M 2011 F

Part of the Deutz F3M2011 engine family — 2 variants share parts & fitment.

2.33 L
Displacement
1500 rpm
Rated speed
5.5 L
Oil capacity

Engine specifications

Oil capacity5.5 L
Coolant capacity8.0 L
Displacement2.33 L
Aspirationnatural
Rated speed1500 rpm

Generator sets powered by this engine

1
Atlas Copco QAX 20 Dd

How to read your Deutz engine serial & model number →

Common problems

9
  • The starter motor turns the engine too slowly
    Cause: Battery capacity too low. Bad electrical connection. Fault in starter motor. Wrong grade of lubricating oil.
  • The engine does not start or is difficult to start
    Cause: Starter motor turns engine too slowly. Fuel tank empty. Fault in fuel control solenoid. Restriction in a fuel pipe. Fault in fuel lift pump. Dirty fuel filter element. Air in fuel system. Fault in atomisers. Cold start system used incorrectly. Fault in cold start system. Restriction in fuel tank vent. Wrong type or grade of fuel used. Restriction in exhaust pipe.
  • Not enough power
    Cause: Restriction in a fuel pipe. Fault in fuel lift pump. Dirty fuel filter element. Restriction in air filter/cleaner or induction system. Air in fuel system. Fault in atomisers or atomisers of an incorrect type.
  • No residual voltage
    Fix: For an instant apply on the + and – terminals of the electronic regulator a 12 V battery voltage with a 30 Ω resistor in series respecting the polarities.
  • Low voltage at no load
    Cause: Voltage potentiometer out of setting.
    Fix: Reset voltage potentiometer.
  • Insufficient residual voltage
    Fix: Increase the speed by 15%.
  • High voltage at no load
    Cause: Voltage potentiometer out of setting.
    Fix: Reset voltage potentiometer.
  • Alternator does not excite
    Cause: Blown fuse.
    Fix: Replace fuse.
  • After being excited alternator does not excite
    Cause: Connections are interrupted.
    Fix: Check connection cables as per attached drawings.

Compiled from service & troubleshooting documentation across every generator set that uses the Deutz F3M 2011 F.

Service intervals

9
ItemActionHoursMonthsNotes
Brake adjustmentCheckFirst service — After the first 100 km travel
Brake systemCheck6 moTwice a year
Earth leakage relay N13Test1 moMust be tested monthly by pushing test button T13
Lighting tower (condition, bolt tightness, fixation of elevation cable)Check6 moAt least twice a year
Towbar bolts, axle bolts and wheel nutsCheck6 moFirst service — At least twice a year and after the initial 50 hours of operation
Vibration dampersCheck6 moCheck the condition twice a year
Wheel axle suspension bearings and brake handle spindleLubricate6 moAt least twice a year; ball bearing grease for wheel bearings, graphite grease for drawbar and spindle
Wheel hub bearingsLubricate12 moRepack once a year using grease
Wheel nuts and towbar boltsCheckFirst service — After the first 100 km travel: check and retighten to specified torque

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Service specifications

47
TypeItemValueUnitCondition
GapBrake lining thickness, replace when worn to1mm
OtherAltitude capability2500m
OtherAltitude capability4000m
OtherCoolant pH limits, outside which coolant should be replacedbelow 7 or above 9.5
OtherCoolant pH typical value for EG8.6
OtherFrequency droop< 5%
OtherFrequency droop< 8%
OtherGlycol concentration in coolant, maximum recommended68vol.%
OtherGlycol concentration in coolant, minimum> 33vol.%
OtherPerformance class (acc. ISO 8528-5:1993)G1
OtherPerformance class (acc. ISO 8528-5:1993)G2
PressureEngine oil pressure shut down switch activates at0.5bar
ResistanceAlternator insulation resistance (IT-config)10-100kOhm
ResistanceAlternator insulation resistance minimum1MΩ
ResistanceInsulation monitoring relay N14 factory setting13kOhmfactory set
SpeedRated speed1500rpm
TemperatureEngine coolant temperature shut down switch activates at105°C
TemperatureMaximum ambient temperature50°C
TemperaturePARCOOL EG antifreeze protection-40°C
TorqueBolts, axle/beams80 ± 10Nm
TorqueBolts, engine/drive housing (M12)80 ± 10Nm
TorqueBolts, engine/drive housing (M14)125 ± 10Nm
TorqueBolts, lifting eye/flywheel housing205 + 20Nm
TorqueBolts, towbar/axle80 ± 10Nm
TorqueBolts, towbar/bottom80 ± 10Nm
TorqueBolts, towing eye/towbar80 ± 10Nm
TorqueHexagon screws/nuts M10, strength grade 12.978Nm
TorqueHexagon screws/nuts M10, strength grade 8.846Nm
TorqueHexagon screws/nuts M12, strength grade 12.9135Nm
TorqueHexagon screws/nuts M12, strength grade 8.880Nm
TorqueHexagon screws/nuts M14, strength grade 12.9210Nm
TorqueHexagon screws/nuts M14, strength grade 8.8125Nm
TorqueHexagon screws/nuts M16, strength grade 12.9345Nm
TorqueHexagon screws/nuts M16, strength grade 8.8205Nm
TorqueHexagon screws/nuts M6, strength grade 12.915Nm
TorqueHexagon screws/nuts M6, strength grade 8.89Nm
TorqueHexagon screws/nuts M8, strength grade 12.939Nm
TorqueHexagon screws/nuts M8, strength grade 8.823Nm
TorqueJoints adjustable towbar M24275 ± 25Nm
TorqueJoints adjustable towbar M32375 ± 25Nm
TorqueLifting beam40 ± 10Nm
TorqueLocking nut towbar height adjustment ZV 2000250-300Nm
TorqueLocking nut towbar height adjustment ZV 2500350-400Nm
TorqueRated active power (PRP) 3ph9.6kWreference conditions
TorqueSafety switches35 ± 5Nm
TorqueWheel nuts80 + 10/- 0Nm
VoltageElectrical system12Vdc

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Recommended fluids

FluidGradeStandardAmbientCapacityNotes
CoolantPARCOOL EG8.0 lReady to use Ethylene Glycol based coolant, premixed 50/50, guaranteed to -40°C; coolant capacity 8 l; never mix different coolants
Engine oilPAROIL 5W30ISO 3448-25°C to 30°CSynthetic ultra high performance diesel engine oil; never mix synthetic with mineral oil
Engine oilPAROIL 15W40ISO 3448-15°C to 40°CMineral based high performance diesel engine oil; 6 l (QAX 12), 5.5 l (QAX 20/30); never mix oils of different brands or types
Fuellow sulphur dieselPAROIL is optimized for EURO-3 & -2, EPA TIER II & III engines running on low sulphur diesel
Greaseball bearing greaseFor wheel bearings
Greasegraphite greaseFor drawbar and spindle

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Procedures

12
Brake cable adjustment adjustment

⚠ Before towing the generator, ensure the towing equipment of the vehicle matches the towing eye

Tools: Jack, Blocks

  1. Pull the towing eye out to the outermost position; hand brake lever downward.
  2. Loosen the lock nuts.
  3. Turn adjusting nuts and brake cable nuts clockwise until no slack remains.
  4. Keep the equalizer perpendicular to the main brake cable.
  5. Apply the hand brake lever several times and repeat the adjustment.
  6. Tighten the nuts with their lock nuts.
  7. Remove the jack and the blocks.
  8. Road test the generator and brake several times.
Brake shoe adjustment adjustment

⚠ Before jacking up the generator, connect it to a towing vehicle or attach a weight of minimum 50 kg to the towbar

Tools: Wrench, Pin 4 mm

  1. Check brake lining thickness through the plugs (5); replace shoes at 1 mm or less.
  2. Lift and support the generator; make sure all brakes are off.
  3. Lock the swivel cams from outside using a 4 mm pin.
  4. Turn the adjusting bolt clockwise with a wrench until the wheel locks up.
  5. Center the brake shoes by actuating the parking brake several times.
  6. Turn the adjusting bolt anti-clockwise until the wheel runs free (approx. 1 full turn).
  7. Check the equalizer is perpendicular with the parking brake actuated.
  8. Remove the locking pin and check all lock nuts.
Height adjustment (with adjustable towbar) adjustment

⚠ Height adjustment should be undertaken on levelled ground and in coupled condition

Tools: Support tools, Extension tube

  1. Remove spring pin (1).
  2. Release locking nut (2) with extension tube (3).
  3. Adjust required height of the towbar.
  4. Tighten locking nut (2) by hand first.
  5. Tighten locking nut (2) to the torque in the table.
  6. Fix locking nut (2) with spring pin (1).
Activating a dry-charged battery maintenance

⚠ Before handling batteries, read the relevant safety precautions

Tools: Electrolyte (sulphuric acid solution in distilled water)

  1. Take out the battery.
  2. Battery and electrolyte must be at equal temperature above 10°C.
  3. Remove cover and/or plug from each cell.
  4. Fill each cell with electrolyte until level reaches 10 to 15 mm above plates.
  5. Rock the battery a few times so air bubbles escape; wait 10 minutes and recheck.
  6. Refit plugs and/or cover.
  7. Place the battery in the generator.
Battery maintenance maintenance

⚠ Observe all relevant environmental and safety precautions

Tools: Petroleum jelly

  1. Keep the battery clean and dry.
  2. Keep the electrolyte level at 10 to 15 mm above the plates.
  3. Top up with distilled water only.
  4. Keep terminals and clamps tight, clean and lightly covered with petroleum jelly.
Cleaning coolers maintenance

⚠ Never steam clean the alternator

⚠ Never leave spilled liquids in or around the generator

Tools: Fibre brush, Steam cleaner

  1. Keep the oil-cooler clean to maintain cooling efficiency.
  2. Remove fan cowl upper part to reach fan side surface of oil cooler.
  3. Remove centre part of front baffles to reach opposite surface.
  4. Steam cleaning with a cleansing agent may be applied.
  5. Remove dirt with a fibre brush; never use a wire brush or metal objects.
  6. Angle jet at approx. 90° to the coolers to avoid damage.
  7. Protect electrical and controlling equipment and air filters against moisture.
  8. Close the service doors afterwards.
Cleaning fuel tank maintenance

⚠ Never leave spilled liquids in or around the generator

Tools: Drain pan

  1. Place an appropriate drain pan under the drainplug of the fuel tank.
  2. Remove the drain plug.
  3. Lift the towbar and tilt the generator approx. 15° to remove all fuel, dirt and water.
  4. Clean the fuel tank and fix the drain plug handtight.
  5. Refill the fuel tank with clean fuel.
Recharging a battery maintenance

⚠ When charging batteries, each cell must be open

Tools: Automatic battery charger

  1. Check electrolyte level in each cell before and after charging; top up with distilled water only.
  2. Keep each cell open, i.e. plugs and/or cover removed.
  3. Prefer the slow charging method.
  4. Set charge current to battery capacity in Ah divided by 20.
  5. Use a commercial automatic battery charger according to its manufacturer's instructions.
Replacing the air filter element maintenance

⚠ Never run the generator without air filter element

⚠ The safety cartridge cannot be cleaned

  1. Release the snap clips and remove the dust trap; clean the trap.
  2. Remove the element from the housing.
  3. Inspect new elements for tears or punctures before installation.
  4. Discard the element when damaged.
  5. Reassemble in reverse order of dismantling.
  6. Inspect and tighten all air intake connections.
  7. Reset the vacuum indicator.
Replacing the coolant maintenance

⚠ Never remove the cooling system filler cap while coolant is hot

⚠ Never mix different coolants

⚠ Topping up with water only is not allowed

  1. Drain the entire cooling system completely.
  2. Dispose or recycle used coolant per local laws.
  3. Flush twice with clean water.
  4. Determine amount of PARCOOL EG required and pour into the radiator top tank.
  5. Run the engine until normal operating temperature is reached, then stop and cool.
  6. Recheck coolant level and add if necessary.
Replacing the fuel filter element maintenance

⚠ Never leave spilled liquids in or around the generator

  1. Unscrew the filter element from the adapter head.
  2. Clean the adapter head sealing surface.
  3. Lightly oil the gasket of the new element.
  4. Screw the new element onto the header until the gasket is properly seated.
  5. Tighten with both hands.
  6. Check for fuel leaks once the engine has been restarted.
Erection of the lighting tower operation

⚠ The lighting tower should never be left unattended

⚠ Before moving the unit, ALWAYS lower the mast and secure it on the transport frame

⚠ When the genset is mounted on a lighting tower it is NOT permitted to use the lifting eye

  1. Position the generator: rear-end upwind, immobilize with handbrake or chocks, level with jockey wheel.
  2. Extend the four stabilizers as far as possible and lock with levers HLS.
  3. Unlock and lower the stabilizer feet; lock in a foreseen hole.
  4. Wind down the foot until it touches the ground and clamps the stabilizer firmly.
  5. Loosen the elevation cable by turning the winding mechanism lever clockwise.
  6. Unlock the mast by raising lever LTF at the back of the transport frame.
  7. Raise the mast from horizontal to vertical; check the locking pin secures the vertical position.
  8. Raise the mast to the desired height by turning the winding mechanism lever.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Parts cataloged across the Deutz F3M2011 family

1
Part #DescriptionCategory
F3M2011IL OilOil filter

Parts cataloged across all variants of this engine family — verify the exact part fits your specific variant and serial number before ordering.

Aftermarket parts that fit this engine

60
04103812 FridayParts $52.80 04103808 FridayParts $52.80 04213069 FridayParts $29.98 FP-XP-0040400 S200-64H FridayParts $409.00 04283323KZ FridayParts $519.90 FP-XP-0006022 FP-XP-0011848 tcd3 SinoCMP $259.00 FP-XP-0011825 FP-XP-0011654 FP-XP-0011589 FP-XP-0033611 ACD110-24 FridayParts $618.35 acd110 FP-XP-0040907 0419-9900 FridayParts $68.32 FP-XP-0022436 0419-9904 FridayParts $75.00 FP-XP-0022369 FP-XP-0022364 75366GT FridayParts $50.20 FP-XP-0022309 FP-XP-0010468 Fl912W FridayParts $47.78 BCD1669 FP-XP-0010452 FP-XP-0010371 tcd7 FP-XP-0010291 FP-XP-0001891 FP-XP-0001728 FP-XP-0013236 TD3.6 FridayParts $79.00 FP-XP-0013202 PC1M2073 FridayParts $268.18 FP-XP-0013062 0423-3304 FridayParts $609.00 FP-XP-0013060 TD2009L04 FridayParts $1490.91 9323A232G FridayParts $1490.91 FP-XP-0012961 FP-XP-0012950 FP-XP-0034650 FP-XP-0034435 tcd2 SinoCMP $159.00 FP-XP-0005121 FP-XP-0041903 FP-XP-0041880 FP-XP-0041876 FP-XP-0007149 FP-XP-0017891 FP-XP-0017553 F3M101 FridayParts $55.00 FP-XP-0017519 FP-XP-0017509 4Pcs FridayParts $7.88 SinoCMP $25.90 FP-XP-0002340 FP-XP-0002329 FP-XP-0038874

Parts listed by aftermarket suppliers as fitting this engine — leads compiled from supplier catalogs; verify the exact part for your serial number.

Also used in

4
  • Ditch Witch RT40 — Trencher
  • Gehl 4640 — Skid Steer Loader
  • Gehl SL4640 — Skid Steer Loader
  • Wirtgen W 35 — Milling Equipment

Other equipment known to use this engine, via filter-application cross-reference — useful for sourcing parts even when your exact machine isn't listed elsewhere on this page.

Common questions

What is the oil capacity of the Deutz F3M 2011 F?

The Deutz F3M 2011 F engine has an oil capacity of 5.5 liters.

What is the displacement of the Deutz F3M 2011 F?

The Deutz F3M 2011 F has a displacement of 2.33 liters.

Which generators use the Deutz F3M 2011 F engine?

The Deutz F3M 2011 F powers 1 generator set(s), including Atlas Copco QAX 20 Dd.

What is a common problem with the Deutz F3M 2011 F engine?

A commonly reported issue on generators using the Deutz F3M 2011 F is: The starter motor turns the engine too slowly. Cause: Battery capacity too low. Bad electrical connection. Fault in starter motor. Wrong grade of lubricating oil..