HomeEnginesCummins/Onan CCK-3CR/16000S

Cummins/Onan CCK-3CR/16000S Engine Engine

The Cummins/Onan CCK-3CR/16000S is a 8.16 L 2-cylinder air cooled, l-head, horizontally opposed engine rated at 1800 rpm. It powers generator sets from Cummins/Onan, including the CC. It holds 3.79 L (1.0 gal) of oil.

Also known as: Onan CCK-3CR/16000S

8.16 L
Displacement
2
Cylinders
1800 rpm
Rated speed
3.79 L
Oil capacity

Engine specifications

Oil capacity3.79 L
Displacement8.16 L
Cylinders2
AspirationAir Cooled, L-Head, Horizontally Opposed
Rated speed1800 rpm

Generator sets powered by this engine

1

Common problems

15
  • VOLTAGE UNSTEADY BUT ENGINE NOT MISFIRING
    Cause: Speed too low.
    Fix: Adjust governor to correct speed.
  • VOLTAGE LOW AT FAR END OF LINE BUT NORMAL NEAR POWER PLANT
    Cause: Too small line wire for load and distance.
    Fix: Install larger or extra wires. Or reduce load.
  • The speed may remain about the same or increase when the load is applied, resulting in a frequency 1 or 2-cycles Aigker than the no load frequency.
    Fix: If the rise in frequency is more than 2-cycles, lessen the internal spring tension. If there is a drop in the frequency, increase the booster internal spring tension. To increase the tension, pull out on the spring bracket, and move the pin to a different hole.
  • Spark plug burned or carboned.
    Fix: Install new plug.
  • Sludge on oil cup screen.
    Fix: Clean screen & air sump.
  • SHARP METALLIC THUD, ESPECIALLY WHEN COLD ENGINE FIRST STARTED
    Cause: Low oil supply.
    Fix: Add oil.
  • Preignition can occur causing engine damage.
    Cause: Not removing lead deposits before switching from leaded to non-leaded gasoline.
  • PINGING SOUND WHEN ENGINE IS SUDDENLY OR HEAVILY LOADED!
    Cause: Wrong spark plug.
    Fix: Install correct spark plug.
  • Operating problems due to the fuel system.
    Fix: Check the fill cap to make sure the vacuum and pressure relief valve is working properly.
  • Oil too light or diluted from leaking fuel pump diaphragm.
    Fix: Drain. Refill with proper oil. Repair or replace fuel pump.
  • Oil too heavy grade.
    Fix: Drain. Refill.
  • Oil taa low.
    Fix: Add oil.
  • Oil relief valve stuck.
    Fix: Clean by-pass. Replace if needed.
  • Oil badly diluted.
    Fix: Change oil.
  • Low or Discharged Battery
    Fix: Faulty Starter, Faulty Start Solenoid

Compiled from service & troubleshooting documentation across every generator set that uses the Cummins/Onan CCK-3CR/16000S.

Maintenance schedule

ItemSpecCapacityPart #Interval
Air filter500 hr find
Fuel filter500 hr find
Oil filter500 hr find
BeltPlace a drop of light oil on breaker arm pivot shaft every 200 operating hours. find
CoolantChange Coolant
OilAPI SE or SE/CC (gasoline operation only)3.79 liters100 hr

Pooled from every document that names this exact engine — confirm the interval and part number against your unit's serial number.

Common questions

What is the oil capacity of the Cummins/Onan CCK-3CR/16000S?

The Cummins/Onan CCK-3CR/16000S engine has an oil capacity of 3.79 liters.

What is the displacement of the Cummins/Onan CCK-3CR/16000S?

The Cummins/Onan CCK-3CR/16000S has a displacement of 8.16 liters with 2 cylinders.

Which generators use the Cummins/Onan CCK-3CR/16000S engine?

The Cummins/Onan CCK-3CR/16000S powers 1 generator set(s), including Cummins/Onan CC.

How often should you change the oil in the Cummins/Onan CCK-3CR/16000S?

The Cummins/Onan CCK-3CR/16000S oil change interval is every 100 hours.

What is a common problem with the Cummins/Onan CCK-3CR/16000S engine?

A commonly reported issue on generators using the Cummins/Onan CCK-3CR/16000S is: VOLTAGE UNSTEADY BUT ENGINE NOT MISFIRING. Cause: Speed too low.. Fix: Adjust governor to correct speed..