Cummins/Onan EH65V Engine Engine
The Cummins/Onan EH65V is a 0.65 L 2-cylinder ohv engine rated at 2400 rpm, producing up to 9.6 kW. It powers generator sets from Cummins/Onan, including the Q and QG 5500. It holds 1.9 L (0.5 gal) of oil.
Also known as: Cummins Onan EH65V
Engine specifications
| Oil capacity | 1.9 L |
|---|
| Displacement | 0.653 L |
|---|
| Cylinders | 2 |
|---|
| Aspiration | OHV |
|---|
| Rated speed | 2400 rpm |
|---|
| Gross power | 9 kW |
|---|
Generator sets powered by this engine
2
Common problems
7- Unit Starts And Runs, Then Stops When The Start Switch Is Released
Cause: Low fluid levels, Possible overheating, Other functional problem
Fix: Check & bring all fluids up to the appropriate levels, Check for blocked air flow or other possible causes of overheating, Contact an Cummins Onan Authorized RV Service & Parts Dealer - Unit Runs Then Surges
Cause: Loose or worn spark plug leads, Defective ignition coil, wiring, or control components, Faulty spark plug, Governor out of adjustment, Combustion air pre-heat malfunction, Carburetor icing, Carburetor varnishing
Fix: Check spark plug leads at spark plug & ignition coil, Contact an Cummins Onan Authorized RV Service & Parts Dealer, Remove spark plug & clean or replace, Contact an Cummins Onan Authorized RV Service & Parts Dealer, Contact an Cummins Onan Authorized RV Service & Parts Dealer, Contact an Cummins Onan Authorized RV Service & Parts Dealer - Unit Runs Then Stops, Or Stops When Driving Around A Corner
Cause: Low fuel level, Low oil level, Excess oil
Fix: Add fuel, Add oil, Reduce engine oil level - Fails To Crank
Cause: Low battery, Bad battery connection, Blown fuse
Fix: Check battery fluid level, Clean & tighten all battery & cable connections, Replace fuse on control panel - Exhausting Black Smoke
Cause: Dirty air filter
Fix: Replace air filter - Cranks But Won’t Start
Cause: Fuel below generator pickup level in tank, Fuel supply shutoff valve closed, Carbon deposits on spark plug(s), Low oil level
Fix: Add fuel, Fully open fuel supply valve, Remove spark plug(s) and replace, Add oil - Circuit Breaker Trips
Cause: Overloaded circuit
Fix: Turn-off some of the electrical load, and reset the circuit breaker
Compiled from service & troubleshooting documentation across every generator set that uses the Cummins/Onan EH65V.
Maintenance schedule
| Item | Spec | Capacity | Part # | Interval | |
|---|
| Air filter | | | — | | find |
| Fuel filter | | | — | | find |
| Oil filter | | | — | | find |
| Belt | | | — | | find |
| Coolant | | | — | | |
| Oil | | 2.0 qt (1.9 L) | — | | |
Pooled from every document that names this exact engine — confirm the interval and part number against your unit's serial number.
Common questions
What is the oil capacity of the Cummins/Onan EH65V?
The Cummins/Onan EH65V engine has an oil capacity of 1.9 liters.
What is the displacement of the Cummins/Onan EH65V?
The Cummins/Onan EH65V has a displacement of 0.653 liters with 2 cylinders.
Which generators use the Cummins/Onan EH65V engine?
The Cummins/Onan EH65V powers 2 generator set(s), including Cummins/Onan Q, Cummins/Onan QG 5500.
What is a common problem with the Cummins/Onan EH65V engine?
A commonly reported issue on generators using the Cummins/Onan EH65V is: Unit Starts And Runs, Then Stops When The Start Switch Is Released. Cause: Low fluid levels, Possible overheating, Other functional problem. Fix: Check & bring all fluids up to the appropriate levels, Check for blocked air flow or other possible causes of overheating, Contact an Cummins Onan Authorized RV Service & Parts Dealer.