HomeEnginesCaterpillar 3412 CTA

Caterpillar 3412 CTA Engine Engine

The Caterpillar 3412 CTA is a 27.02 L 6-cylinder cta engine rated at 2100 rpm, producing up to 560 kW. It powers generator sets from Caterpillar, including the 3412C TA and SR4B. It holds 139 L (36.7 gal) of oil and 59 L (15.6 gal) of coolant.

Also known as: Caterpillar 3412 CTA

27.02 L
Displacement
6
Cylinders
2100 rpm
Rated speed
560 kW
Gross power

Engine specifications

Oil capacity139.0 L
Coolant capacity59.0 L
Displacement27.02 L
Cylinders6
AspirationCTA
Rated speed2100 rpm
Gross power560 kW

Generator sets powered by this engine

2

Common problems

15
  • When the engine oil pressure is increased beyond the low oil pressure setpoint, the GSC will inform the governor that the engine speed should be increased from IDLE to RATED rpm. 2301A Control
  • The GSC+ detects an alarm fault
    Fix: Fault alarm indicator (26) is accompanied by an alarm fault code that is shown on the upper display (29) when the alarm codes key (30) is pressed.
  • The GSC+ detects a shutdown fault
    Fix: The engine will shut down if the engine is running. The engine will not be allowed to start.
  • The fault alarm indicator (3) flashes when the GSC detects an alarm fault. g00604607
  • Overcrank
    Cause: Engine does not start within the setpoint for overcrank.
  • Low oil pressure indicator flashes, and the engine is shut down.
    Cause: The engine oil pressure drops below the setpoints for low oil pressure shutdown that are programmed into the GSC. There are two low oil pressure setpoints. One setpoint is used when the engine is at idle speed. The other setpoint is used when the engine is at rated speed.
  • Low oil pressure
    Cause: Engine oil pressure drops below the setpoints for low oil pressure shutdown that are programmed into the GSC+.
    Fix: The tow oil pressure indicator FLASHES, and the engine is shut down. The engine is not allowed to start until the fault is corrected.
  • High water temperature indicator flashes, and the engine is shut down.
    Cause: The engine coolant temperature rises above the setpoint for high water temperature shutdown that is programmed into the GSC.
  • High water temperature
    Cause: Engine coolant temperature rises above the setpoint for high water temperature shutdown that is programmed into the GSC+.
    Fix: The engine is shutdown and the engine is not allowed to start until the fault is corrected.
  • Generator parameters are not matched to the bus
    Fix: If the generator and bus voltages, frequencies and phases are in sync, the lamps will light continuously. If not, the associated lamp will flash.
  • Fault shutdown 21
  • Fault alarm 22
  • Engine overspeed indicator flashes, and the engine is shut down.
    Cause: The engine speed exceeds a certain threshold set in the GSC+.
    Fix: Correct the condition by addressing any issues that caused the engine to overspeed.
  • Engine overspeed
    Cause: Engine speed exceeds the setpoint for engine overspeed that is programmed into the GSC+.
    Fix: The engine is shutdown and the engine is not allowed to start until the fault is corrected.
  • Engine overcrank indicator flashes, and the engine is shut down.
    Cause: The engine has been cranked for an extended period without starting.
    Fix: Correct the condition by ensuring proper start-up procedures are followed.

Compiled from service & troubleshooting documentation across every generator set that uses the Caterpillar 3412 CTA.

Maintenance schedule

ItemSpecCapacityPart #Interval
Air filterSingle element canister type air cleaner, Service indicator1250 hr find
Fuel filterPrimary and secondary fuel filters, Water separator51344901250 hr PartsGeek $48.97
Oil filter1250 hr find
BeltFan and belt guards, Exhaust flex and ANSI style outlet flange, gasket, bolts and mating weld flange1250 hr find
CoolantCat® Extended Life Coolant90.0 L6000 hr
OilSump refill with filter69.0 L

Pooled from every document that names this exact engine — confirm the interval and part number against your unit's serial number.

Filters for this engine

  • Air filter: Caterpillar 7T1S90 Caterpillar 7W6611 Caterpillar 1063973 Caterpillar 612506 Donaldson P525026 Donaldson P525129 Donaldson P533884 Donaldson P532506
  • Fuel filter (primary): Caterpillar 5134490 Donaldson P551858 Wix 33780
  • Oil filter: Caterpillar 3890434 Caterpillar 2P4005 Donaldson P551808 Donaldson P554005 Wix 57792 Wix 51792 Ac Delco PF879L

Cross-referenced via Donaldson + OEM/engine-maker interchange — options to verify against your serial number, not confirmed for every exact variant.

Also used in

5
  • Caterpillar 992C — Loader Wheeled
  • Caterpillar 992D — Loader Wheeled
  • Caterpillar D10N — Tractor Tracked
  • Caterpillar D9L — Tractor Tracked
  • Manitowoc 4599 SERIES 4 — Dragline

Other equipment known to use this engine, via filter-application cross-reference — useful for sourcing parts even when your exact machine isn't listed elsewhere on this page.

Common questions

What is the oil capacity of the Caterpillar 3412 CTA?

The Caterpillar 3412 CTA engine has an oil capacity of 139.0 liters.

What is the displacement of the Caterpillar 3412 CTA?

The Caterpillar 3412 CTA has a displacement of 27.02 liters with 6 cylinders.

Which generators use the Caterpillar 3412 CTA engine?

The Caterpillar 3412 CTA powers 2 generator set(s), including Caterpillar 3412C TA, Caterpillar SR4B.

What oil filter does the Caterpillar 3412 CTA use?

The Caterpillar 3412 CTA uses oil filter part numbers Caterpillar 3890434, Caterpillar 2P4005, Donaldson P551808.

What fuel filter does the Caterpillar 3412 CTA use?

The Caterpillar 3412 CTA uses fuel filter part numbers Caterpillar 5134490, Donaldson P551858, Wix 33780.

What air filter does the Caterpillar 3412 CTA use?

The Caterpillar 3412 CTA uses air filter part numbers Caterpillar 7T1S90, Caterpillar 7W6611, Caterpillar 1063973.

What is a common problem with the Caterpillar 3412 CTA engine?

A commonly reported issue on generators using the Caterpillar 3412 CTA is: When the engine oil pressure is increased beyond the low oil pressure setpoint, the GSC will inform the governor that the engine speed should be increased from IDLE to RATED rpm..