Home›Engines›Caterpillar 3508B

Caterpillar 3508B Engine

The Caterpillar 3508B is a 34.5 L 8-cylinder ta engine rated at 1800 rpm, producing up to 698 kW. It powers generator sets from Caterpillar, including the 3508. It holds 397 L (104.9 gal) of oil and 103 L (27.2 gal) of coolant.

Also known as: Caterpillar 3508B, 3508B

34.5 L
Displacement
8
Cylinders
1800 rpm
Rated speed
698 kW
Gross power

Service parts for the 3508B

The cheapest captured merchant offer per filter — see the full cross-reference below for every OEM/aftermarket option.

Oil system

1 required

Prices captured from merchant listings; some links are affiliate links. Verify against your serial number before ordering.

Engine specifications

Oil capacity397.0 L
Coolant capacity103.0 L
Displacement34.5 L
Cylinders8
AspirationTA
Rated speed1800 rpm
Gross power698 kW

Maintenance schedule

ItemSpecCapacityPart #Interval
Air filterAir conditionerR134a Amazon Amazon eBay $585.30 eBay FridayParts $25.50
Oil filter175-7546 Amazon eBay
Battery245-5829 Amazon eBay $98.00
Coolant294-7420 Amazon eBay
Oil227.1 L—500 hr

Pooled from every document that names this exact engine — confirm the interval and part number against your unit's serial number.

Service intervals

40
ItemActionHoursMonthsNotes
SystemTest1 hrToCI quarterly: exercise system under full load for 1 hour
Battery Electrolyte LevelCheck250 hrEvery 250 Service Hours
BeltsInspect250 hrInspect/Adjust/Replace; Every 250 Service Hours
Cooling System Coolant Sample (Level 1)Other250 hrObtain; Every 250 Service Hours
Cooling System Supplemental Coolant Additive (SCA)Test250 hrTest/Add; Every 250 Service Hours
Engine Oil SampleOther250 hrObtain; Every 250 Service Hours
Engine Oil SampleTest250 hrEvery 250 Service Hours - Obtain
Engine Valve LashAdjust4000 hrFirst service — Inspect/Adjust; Initial 250 Service Hours
Fan Drive BearingLubricate250 hrEvery 250 Service Hours
Fuel InjectorAdjust4000 hrFirst service — Inspect/Adjust; Initial 250 Service Hours
Hoses and ClampsInspect250 hrInspect/Replace; Every 250 Service Hours
RadiatorClean250 hrEvery 250 Service Hours
Speed SensorClean250 hrFirst service — Initial 250 Service Hours (Prime Power) - Clean/Inspect
Air ShutoffTest500 hrEvery 500 Service Hours (Prime Power)
Cooling System Coolant Sample (Level 1)Test500 hrEvery 500 Service Hours (Prime Power)
Cooling System Coolant Sample (Level 2)Test500 hrFirst service — Initial 500 Hours for new, refilled and converted systems
Engine Oil and FilterChange500 hrEvery 500 Service Hours - standard sump; deep sump every 1000 hours
Magnetic PickupsClean500 hrFirst service — Clean/Inspect; Initial 500 Service Hours or at first oil change
Cooling System Coolant Sample (Level 2)Other1000 hrObtain; Every 1000 Service Hours
EngineClean1000 hrEvery 1000 Service Hours
Engine Crankcase BreatherClean1000 hrEvery 1000 Service Hours
Engine Protective DevicesCheck1000 hrEvery 1000 Service Hours
Engine Protective DevicesTest1000 hrCheck; Every 1000 Service Hours
Fuel System Primary FilterReplace1000 hrEvery 1000 Service Hours - Clean/Inspect/Replace
Fuel System Secondary FilterReplace1000 hrEvery 1000 Service Hours
Generator Winding InsulationTest1000 hrEvery 1000 Service Hours
Rotating RectifierInspect1000 hr12 moEvery 1000 Service Hours or 1 Year - Inspect/Test
Crankshaft Vibration DamperInspect2000 hrEvery 2000 Service Hours
Engine MountsCheck2000 hrEvery 2000 Service Hours
GeneratorOther2000 hr6 moEvery 2000 Service Hours or 6 Months - Dry
Generator Set VibrationTest2000 hrEvery 2000 Service Hours - Test/Record
Stator LeadCheck2000 hr6 moEvery 2000 Service Hours or 6 Months
TurbochargerInspect2000 hrEvery 2000 Service Hours
Cooling System Coolant (DEAC)Change3000 hr36 moEvery 3000 Service Hours or 3 Years
Cooling System Coolant Extender (ELC)Other3000 hr36 moEvery 3000 Service Hours or 3 Years - Add
Air Shutoff DamperCheck6000 hrEvery 6000 Service Hours - Remove/Check
AlternatorInspect6000 hr72 moEvery 6000 Service Hours or 6 Years
Cooling System Coolant (ELC)Change6000 hr72 moEvery 6000 Service Hours or 6 Years
Cooling System Water Temperature RegulatorReplace6000 hr72 moEvery 6000 Service Hours or 6 Years
Prelube PumpInspect6000 hr72 moEvery 6000 Service Hours or 6 Years

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Service specifications

60
TypeItemValueUnitCondition
ClearanceAir shutoff damper plunger distance A (minimum)18.3mm0.72 inch; replace plunger if less
ClearanceCoolant level below bottom of filler pipe13mmno sight gauge
ClearanceCrankshaft end play.178 to .635mm (0.0070 to 0.0250 inch)measured with dial indicator
ClearanceCrankshaft end play after assembly0.178 to 0.635mm (0.0070 to 0.0250 inch)after assembly
ClearanceEnd play at heat sink after assembly0.076 to 0.635mm (0.0030 to 0.0250 inch)after assembly
ClearanceGap at 3, 6, 9, 12 o'clock positions0.03 to 0.13mm (0.001 to 0.005 inch)between
ClearanceGap between generator and flywheel housing at locations (E), (F), (G), (H)>0.03 and <0.13mm (0.001 inch to 0.005 inch)more than 0.03 mm and less than 0.13 mm
ClearanceGenerator forward offset from midpoint of end play+ 0.50mm (+ 0.0200 inch)while generator supported by crane
ClearanceRotor end play3.81 to 7.62mm (.150 to .300 inch)approximately
ClearanceShim thickness divisor for number of shims0.8mm (0.03 inch)divide Letter L by this value
ClearanceSupport deflection during bolt tightening0.13mm (0.005 inch)maximum allowed movement
GapAir shutoff damper plunger distance A (replace if less)18.3mm
OtherAir cleaner element cleaning limitsix timesreplace at least once per year regardless
OtherAltitude capability without derate1525m
OtherAltitude capability without derate800m
OtherCoolant Sample (Level 1) interval for Cat DEAC250hours
OtherCooling system cleaner amount (heavy deposits)0.5L per 3.8 to 7.6 L capacity1 pint per 1 to 2 US gal
OtherCooling system cleaner amount (normal deposits)0.5L per 15 L capacity1 pint per 4 US gal
OtherCooling system cleaning duration (heavy deposits)90minutesminimum, coolant at least 82 C (180 F)
OtherCooling system cleaning duration (normal deposits)30minutesminimum, coolant at least 82 C (180 F)
OtherCooling system fill rate maximum19L/min
OtherDamper fluid viscosity degradation limit20percentmajority of applications
OtherDamper fluid viscosity degradation limit (Hasse & Wrede)20percentmajority of applications
OtherDamper operating hours before rebuild/replace (damper without sampling port)20000hours
OtherDamper without sampling port - rebuild/replace interval20000hoursor at major overhaul
OtherExercise under full load1hourToCI quarterly
OtherFast Acting Cooling System Cleaner amount0.5 L per 15 LLcooling system capacity, normal deposits
OtherFast Acting Cooling System Cleaner amount0.5 L per 3.8 to 7.6 LLcooling system capacity, heavy deposits
OtherFull load test duration4hoursOnce per year
OtherGross Input Torque (TH55-E70)12 667N•m (9350 lb-ft)
OtherGross Input Torque (TH55-E90)12 677N•m (9350 lb-ft)
OtherHydrosolv cleaner concentration2 to 5percenttemperatures up to 93 C (200 F)
OtherLoad bank data recording interval15minutesDuring load bank test
OtherLoad bank test load level80% of generator nameplate capacity4-hour resistive load bank test
OtherLoad bank test profile2 hours at 50%, 1 hour at 75%, 1 hour at 100%Annual four (4) hour load bank test
OtherMaximum air pressure at nozzle for cleaning purposes205kPa30 psi
OtherNew drive belt tension recheck after operation30minutesrated rpm
OtherRating condition (diesel 7 L and higher)99 kPa (29.31 in Hg) dry barometer, 25°C (77°F)SAE J1995 inlet air standard
OtherRating condition (diesel up to 6.6 L)100 kPa (29.5 in Hg) total barometric pressure, 1 kPa (.295 in Hg) vapor pressure, 25°C (77°F)ISO/TR14396 inlet air standard
OtherRating condition (gas)100 kPa (29.61 in Hg) and 25°C (77°F)SAE J1349 standard
OtherStall Torque Ratio (TH55-E70)2.23
OtherStall Torque Ratio (TH55-E90)2.23
OtherStarting motor cool-down between cranking periods2minutes
OtherSupplemental coolant additive concentration maximum (conventional coolant)6percent
OtherSupplemental coolant additive concentration maximum (water and SCA)8percent
OtherThread lock cure time minimum before air shutoff use1hour
PressureAir cleaner service indicator restriction (clean/replace)6kPa25 inches of H2O
PressureEngine air cleaner differential pressure (nominal)3kPanormal engine operation
PressureEngine air cleaner maximum differential pressure (replace element)6.2kPa
PressureEngine oil filter differential pressure (nominal)60kPanormal engine operation
PressureEngine oil filter differential pressure (normal)60kPanormal engine operation
PressureEngine oil filter differential pressure (replace elements)103kPaoil filter elements to be replaced
PressureEngine oil pressure during cranking70kPacranking with fuel off
PressureFuel filter differential pressure (nominal)60kPanormal engine operation
PressureFuel filter differential pressure (normal)60kPanormal engine operation
PressureFuel filter differential pressure (replace secondary elements)103kPafuel filter elements to be replaced
PressureMaximum air pressure at nozzle for cleaning205kPa
PressureMaximum air pressure for cleaning (aftercooler core)205kPa30 psi; at nozzle
PressureMaximum air pressure for cleaning (radiator)205kPa30 psi; deadheaded nozzle
PressureMaximum air pressure for cleaning air cleaner element207kPa30 psi

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Recommended fluids

FluidGradeStandardAmbientCapacityNotes
CoolantCat DEACDiesel; 3,000 Service Hours or Three Years; annual S·O·SSM Level 2 coolant sampling and analysis
CoolantCat DEAC (Diesel Engine Antifreeze/Coolant)Conventional coolant; SCA required; see SEBU6251
CoolantCat ELCDiesel; 12,000 Service Hours or Six Years; add Cat ELC Extender at 6,000 service hours or one half of service life; annual S·O·SSM Level 2 coolant sampling and analysis
CoolantCat ELC (Extended Life Coolant)Add Cat ELC Extender once; do not use conventional SCA with Cat ELC
CoolantCat ELC ExtenderNeeds to be added only once; add per cooling system capacity
CoolantCat NGECNatural Gas; 16,000 Service Hours or Three Years; use interval that occurs first
CoolantCommercial long life / heavy-duty coolant meeting Caterpillar EC-1Caterpillar Engine Coolant Specification -1 (EC-1)Obtain Level 1 coolant sample
CoolantCommercial long life coolant meeting Caterpillar EC-1Caterpillar Engine Coolant Specification -1 (EC-1)
CoolantSupplemental Coolant Additive (SCA)Max 6 percent with conventional coolant; max 8 percent with water and SCA
Engine oilEPA 2D 89.330-96 (fuel reference, Diesel <6.6 L, density 0,845-0,850 kg/L a 15 °C)Reference condition only, not a lubricant recommendation
Engine oilCat NGEONatural Gas
Engine oilair tool oilbelow 0°CAir starting motor lubricator; temperatures below 0 C (32 F)
Engine oillow sulfated ash oilRequired for U.S. EPA Tier 4 Final, EU Stage IV engines.
Engine oilmeeting manufacturer's specsAdd crankcase oil (grade meeting manufacturer's specs) to correct level (SCI)
Engine oilCat Arctic DEO SYN SAE 0W-30-40°C to 30°CEngine Crankcase; Industrial Engines
Engine oilCat DEO SYN SAE 5W-40-30°C to 50°CEngine Crankcase; Industrial Engines
Engine oilCat DEO SAE 10W-30-18°C to 40°CEngine Crankcase; Industrial Engines
Engine oilCat DEO SAE 15W-40-9°C to 50°CEngine Crankcase; Industrial Engines
Engine oilnondetergent SAE 10Wabove 0°CAir starting motor lubricator; temperatures greater than 0 C (32 F)
FuelUltra Low Sulfur Diesel (ULSD)Contains less than or equal to 15 parts per million sulfur (mg/kg); required for U.S. EPA Tier 4 Final, EU Stage IV engines. B20 biodiesel capability available.
Fuel35° API gravity at 60°F (16°C)LHV 18,390 Btu/lb (42 780 kJ/kg)Fuel at 85°F (29°C) weighing 7.001 lbs/U.S. gal (838.9 g/liter)
Fuel35° API gravity, LHV 42 780 kJ/kg (18,390 btu/lb)SAE J1995Diesel engines 7 liter and higher; used at 29°C (84.2°F) with density 838.9 g/L
FuelEPA 2D 89.330-96EPA 2D 89.330-96Diesel engines up to 6.6 liter; density 0.845-0.850 kg/L @ 15°C (59°F); fuel inlet temperature 40°C (104°F)
FuelNo. 2 fuel3600 engines designed for 80 000 hours on No. 2 fuel; ratings based on API gravity of 35 at 15 C (60 F), LHV of 42 780 kJ/kg used at 29 C (84 F) with a density of 838.9 g/L
Fueldry natural gas, LHV 35.54 MJ/Nm3 (905 btu/ft3)Gas ratings based on SAE J1349 standard conditions of 100 kPa (29.61 in Hg) and 25°C (77°F)
GreaseCat Generator Set GreasePart Number 108-8611
GreaseEA6-40°C to 80°CNon-regreasable bearings 311-0843/311-0844
GreaseMobilith SHC220-40°C to 80°C2.8 gRoller bearings 139-0349/139-0350; every 250 service hours
Grease2S-3230 Bearing Lubricant-29°C to 80°C51.2 gGenerator bearings; 59 mL (2 oz); every 2000 service hours or 12 months
GreaseUNIREX N3-29°C to 60°CDo not exceed 60 °C (140 °F) above ambient; some bearings non-regreasable

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Procedures

12
Alignment Of Electric Sets With Supports At The Flywheel Housing / Installation Of A New Generator Or Flexible Plates adjustment

Tools: crane, dial indicator, shims, torque wrench

  1. Loosen all bolts connecting base to foundation; loosen all bolts fastening engine supports and generator supports to base.
  2. Ensure enough clearance between bolts and bolt holes in base, engine supports, generator supports at all locations.
  3. Check clearance between base and foundation at all mounting locations; use shims to prevent deflection; tighten base-to-foundation bolts to final torque.
  4. While generator supported by crane, loosen all bolts (2) fastening generator to flywheel housing; tighten alternate bolts to final torque; check clearance between base and engine and generator support
  5. Tighten all bolts fastening engine supports and generator supports to base to half of final torque; loosen all bolts (2); measure gap between generator and flywheel housing; ensure bolts centered in c
  6. Gaps at (E), (F), (G), (H) should be more than 0.03 mm (0.001 inch) and less than 0.13 mm (0.005 inch); adjust shims or move rear of generator right or left.
  7. After shim correction, tighten generator support bolts to half of final torque 450 N-m (332 Ib ft); check gaps; repeat until 0.13 mm (0.005 inch) or less; begin with Step 5.
  8. Install dial indicator on base with tip next to support mounting bolt (4); put tip on support (3); check while tightening bolt to final torque; if indicator moves more than 0.13 mm (0.005 inch), insta
Alignment Of Electric Sets Without Supports At The Flywheel Housing adjustment

Tools: shims, torque wrench

  1. Loosen all bolts connecting base to foundation; loosen all bolts fastening generator supports and engine supports to base.
  2. Ensure clearance between bolts and bolt holes in base, engine supports, generator supports at all locations.
  3. Check clearance between base and foundation at all mounting locations; use shims to prevent base deflection; tighten base-to-foundation bolts to final torque.
  4. Check clearance between base and engine, base and engine supports, base and generator supports over entire length; use shims to prevent support deflection; tighten all mounting bolts to final torque.
Belts - Adjusting the Alternator Belt adjustment
  1. Remove the drive belt guard.
  2. Loosen mounting bolt (1), adjusting nuts (2) and mounting bolt (3).
  3. Turn adjusting nuts (2) to increase or decrease drive belt tension.
  4. Tighten adjusting nuts (2), mounting bolt (3), and mounting bolt (1).
  5. Reinstall the drive belt guard.
  6. If new belts installed, recheck tension after 30 minutes at rated rpm.
Belts - Inspect/Adjust/Replace adjustment

⚠ Slippage of loose belts can reduce efficiency of driven components

⚠ Too tight belts place unnecessary stress on components

  1. Remove the drive belt guard.
  2. Loosen mounting bolt, adjusting nuts and mounting bolt.
  3. Turn adjusting nuts to increase or decrease drive belt tension.
  4. Tighten adjusting nuts and both mounting bolts to proper torque.
  5. Reinstall the drive belt guard.
  6. If new drive belts are installed, recheck tension after 30 minutes.
Rechecking The Alignment adjustment

Tools: torque wrench, shims

  1. Loosen the sixteen close coupled adapter bolts (2); visually ensure they are centered in clearance holes.
  2. Check gaps at 3, 6, 9, and 12 o'clock positions; use 2, 4, 8, and 10 o'clock if 12 and 6 are inaccessible.
  3. If gaps are between 0.03 mm (0.001 inch) and 0.13 mm (0.005 inch), tighten all bolts; alignment check complete. If not, loosen bolts fastening generator to base frame; adjust shims; move rear of gener
  4. After adjustment, tighten generator mounting bolts to one half of standard torque 450 N-m (332 lb ft); repeat procedure starting with Step 1.
Air Shutoff - Test (ADEM II Engine Control Modules) diagnostic

⚠ Check the wiring for the air shutoff switches, and for the solenoids

  1. Do not start the engine; ensure engine control is OFF.
  2. Verify both air shutoff gates latched OPEN and switches connected.
  3. Turn panel power ON; gates should remain open.
  4. Activate EMERGENCY STOP; both gates should close.
  5. Reset; latch only right gate; power ON; right gate should close.
  6. Latch only left gate; power ON; left gate should close.
  7. Operate engine normally; ensure gates remain latched.
Generator Winding Insulation - Test diagnostic

⚠ High voltage can cause electrocution. Discharge instrument leads and generator windings.

Tools: 300-8648 Insulation Testing Gp

  1. Take the generator out of service.
  2. Visually inspect generator for moisture. If moisture exists, dry the unit first.
  3. Inspect installation. Determine equipment that will be tested.
  4. Discharge capacitance of the windings. Disconnect 'T0' from ground.
  5. Disconnect sensing lead wires for regulator and PT leads of load share module.
  6. Connect insulation tester Black lead to ground; RED lead to 'T0'.
  7. Set voltage to rated voltage. Apply voltage; observe readings at 30 and 60 seconds.
  8. Record 60 second reading (correct for temperature), temperature, and humidity.
Installation Of The Generator For Generator Sets That Are Equipped With A 3500 Engine installation

⚠ Damage to engine and generator can result if electric set is operated with a plate assembly that does not have proper clearance.

⚠ If N or O is less than initial A, disassemble and check coupling plate for bowing; replace if bowed.

Tools: dial indicator, straight edge, magnetic bases, crane, torque wrench, 17 5N-4478 Plates

  1. Ensure generator is disengaged from engine; clean generator support and base contact surfaces; remove protective material from flywheel pilot bearing bore and coupling contact surface.
  2. Remove two engine side covers; rotate engine until no. 1 crankshaft throw is perpendicular; measure crankshaft end play with dial indicator; record as A and divide by two for B.
  3. With crankshaft at extreme forward position, measure distance from straight edge to flywheel housing mounting surface (C) and flywheel pilot surface (D); subtract D from C for E.
  4. Remove coupling bolts and washers; remove plates, shims, and exhaust fan; lift rotor; locate rotor so air gap equal; move rotor to extreme rear.
  5. Place dial indicator on vertical surface of heat sink at rear of rotor shaft; measure rotor end play (approximately 3.81 to 7.62 mm); record F and divide by two for G.
  6. Move rotor to extreme rear; position straight edge across mounting ring diameter; measure distance to mounting ring surface (H) and hub mounting surface (I); subtract H from I for J.
  7. Bolt a standard set of 17 5N-4478 Plates together; measure thickness in two locations along contour; average as K.
  8. Determine number of shims: subtract B, E, G, K from J for L; divide L by 0.8 mm (0.03 inch) for M; round up.
  9. Put coupling plate in flywheel bore; check clearance between coupling plate outside diameter and flywheel bore inside diameter.
  10. Install coupling plate assembly, bolts (6) and calculated shims; tighten bolts (5) in 180 degree intervals in three stages to 525 + 25 N-m (390 + 20 lb ft).
  11. Install guide bolts in flywheel; put generator on engine; install bolts (10); tighten to 100 N-m (75 lb ft) in pairs at 180 degree intervals in three stages.
  12. While crane supports generator, place dial indicator on heat sink vertical surface; push generator forward within + 0.50 mm (+ 0.0200 inch) of midpoint of end play.
  13. Install fan mounting bolts (11) into flywheel; tighten to 200 N-m (150 Ib ft) in pairs at 180 degree intervals in three stages.
  14. Place dial indicators on no. 1 crankshaft throw and heat sink; push crankshaft forward; check crankshaft end play 0.178 to 0.635 mm and heat sink end play 0.076 to 0.635 mm; record N and O.
  15. If N or O is less than initial A, disassemble; check coupling plate for bowing; replace if bowed; check calculations; install generator and repeat steps 13 and 15.
Installation Of The Generator For Generator Sets That Are Not Equipped With A 3500 Engine installation

⚠ Damage to engine and generator can result if electric set is operated with a plate assembly that does not have proper clearance.

Tools: dial indicator, indicator assembly, bar, torque wrench, guide bolt, crane

  1. Remove dirt, burrs, paint from generator support and base contact surfaces; remove protective material from flywheel pilot bearing bore and coupling contact surface.
  2. Remove timing pointer cover; install indicator assembly on front of engine; tip contacts crankshaft pulley face.
  3. Position plate assembly in flywheel bore; check clearance between plate outside diameter and bore inside diameter.
  4. Install full shim pack and plate assembly on generator with bolts; tighten bolts to 525 + 45 N-m (390 + 30 lb ft).
  5. Install guide bolt in flywheel; put generator on engine; install bolts (9) and (10); tighten but do not bend locks under bolts (8).
  6. Use dial indicator to check crankshaft end play; if reading differs from initial, remove generator and enough shims to get original end play.
  7. Install generator again and check crankshaft end play; after correct shims, bend locks under bolts (8).
Aftercooler Core - Inspect/Clean maintenance

⚠ Do not use a high concentration of caustic cleaner

⚠ Do not use high pressure when the fins are cleaned

  1. Remove the core.
  2. Turn the aftercooler core on one side; remove accessible debris.
  3. Back flush the core with cleaner.
  4. Remove the drain plug; steam clean the core; flush the fins.
  5. Wash the core with hot, soapy water.
  6. Flush thoroughly with clean, fresh water until clear.
  7. Dry the core with compressed air opposite to normal flow direction.
  8. Inspect O-rings/seals; pressure test for leaks; install the core.
Automatic Transfer Switch Semi-Annual Service maintenance
  1. Verify proper operation of exerciser clock; adjust if necessary.
  2. Provide visual inspection of all contacts and connection points.
  3. Perform building load test if practical and inspect for proper transfer and re-transfer.
  4. Verify operation of all control lamps.
Batteries - Replace maintenance

⚠ Batteries give off combustible gases which can explode; ensure proper ventilation.

⚠ Always recycle a battery; never discard a battery.

  1. Turn key start switch OFF. Remove key and all electrical loads.
  2. Turn OFF battery charger. Disconnect the charger.
  3. Disconnect NEGATIVE '-' cable from NEGATIVE battery terminal.
  4. Disconnect POSITIVE '+' cable from POSITIVE battery terminal.
  5. Remove the used battery. Install the new battery.
  6. Connect starting motor cable to POSITIVE '+' battery terminal.
  7. Connect ground plane cable to NEGATIVE '-' battery terminal.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Aftermarket parts that fit this engine

60
348-6693 FridayParts $275.56 218-9901 FridayParts $88.10 171-2212 FridayParts $75.99 7N-1961 FridayParts $148.89 375-1478 FridayParts $34.99 3E-6466 FridayParts $73.99 162-2073 FridayParts $73.99 147-7975 FridayParts $217.50 7E-0127 FridayParts $212.23 122-6585 FridayParts $123.56 261-6847 FridayParts $112.35 124-5572 KuduParts $50.00 FridayParts $52.10 2G-1034 FridayParts $13.66 7T-2798 FridayParts $41.23 9S-9082 Amazon eBay $24.58 FridayParts $29.81 0508477 FridayParts $29.81 4D-2287 FridayParts $39.92 346-7515 FridayParts $149.99 8M-3368 FridayParts $27.20 334-5006 FridayParts $769.56 171-8708 FridayParts $97.58 212-5883 FridayParts $156.66 1B-7709 FridayParts $19.99 8N-6861 FridayParts $309.44 110-6993 FridayParts $309.44 118-9494 FridayParts $309.44 211-7826 FridayParts $309.44 440-0257 FridayParts $109.20 155-9879 FridayParts $224.20 133-6350 FridayParts $1301.00 109-4367 FridayParts $179.99 164-2441 FridayParts $120.99 261-6848 FridayParts $159.99 3E-7826 FridayParts $199.59 415-2428 FridayParts $269.59 415-2430 FridayParts $158.99 145-6034 FridayParts $359.99 179-6863 FridayParts $489.99 297-9545 FridayParts $339.89 297-9546 FridayParts $499.99 341-8543 FridayParts $135.99 365-4922 FridayParts $319.99 6V-2696 FridayParts $68.41 7T-0157 FridayParts $68.41 9G-5321 FridayParts $89.99 9W-4651 FridayParts $64.63 9W-6692 FridayParts $89.99 233-7973 KuduParts $891.00 FridayParts $915.75 10R-1264 FridayParts $529.99 2291631 FridayParts $545.30 162-3906 FridayParts $59.98 298-3648 FridayParts $2650.99 4P-6009 FridayParts $45.26 9T-7757 FridayParts $239.56 158-8987 KuduParts $50.00 FridayParts $52.56 126-1813 KuduParts $50.00 FridayParts $52.56 SinoCMP $149.00 112-7913 FridayParts $2069.99 219-1965 FridayParts $2789.99 10R-4648 FridayParts $2789.99 9T-9227 FridayParts $72.88

Parts listed by aftermarket suppliers as fitting this engine — leads compiled from supplier catalogs; verify the exact part for your serial number.

Filters for this engine

  • Oil filter: Caterpillar 3890434 Donaldson P551808 Wix 57792 Baldwin B7299

Cross-referenced via Donaldson + OEM/engine-maker interchange — options to verify against your serial number, not confirmed for every exact variant.

Also used in

9
  • Caterpillar 5130 — Excavator Tracked
  • Caterpillar 5130B — Excavator Tracked
  • Caterpillar 776C — Dump Truck
  • Caterpillar 777B — Dump Truck
  • Caterpillar 777C — Dump Truck
  • Caterpillar 777D — Haul Truck
  • Caterpillar D11N — Tractor Tracked
  • Caterpillar D11R — Tractor Tracked
  • Caterpillar D11R CD — Tractor Tracked

Other equipment known to use this engine, via filter-application cross-reference — useful for sourcing parts even when your exact machine isn't listed elsewhere on this page.

Common questions

What is the oil capacity of the Caterpillar 3508B?

The Caterpillar 3508B engine has an oil capacity of 397.0 liters.

What is the displacement of the Caterpillar 3508B?

The Caterpillar 3508B has a displacement of 34.5 liters with 8 cylinders.

Which generators use the Caterpillar 3508B engine?

The Caterpillar 3508B powers 1 generator set(s), including Caterpillar 3508.

What oil filter does the Caterpillar 3508B use?

The Caterpillar 3508B uses oil filter part numbers Caterpillar 3890434, Donaldson P551808, Wix 57792.

How often should you change the oil in the Caterpillar 3508B?

The Caterpillar 3508B oil change interval is every 500 hours.