| | Grounding/bonding | Bonding conductor; No. 8 AWG copper wire minimum | Ground generator by solid mounting to vehicle frame/chassis or by approved bonding conductor. DO NOT disconnect bonding conductor. If replaced, use only flexible No. 8 AWG copper wire minimum. |
| 120 | | Single voltage AC output (factory connection) | Stator power leads 11P and 33 at the main circuit breakers; 22P and 44 at the 4-tab ground terminal | Most units shipped connected for 120 VAC output only. Some models have a 30 amp and a 20 amp main breaker; others have two 30 amp breakers. |
| 120 | 1 | Connection for 120 Volts Only (Figure 1) | Dual stator power windings; grounded neutral; CB1 | These air-cooled Q Series generator sets are equipped with dual stator AC power windings supplying power by a dual 2-wire connection system. |
| 120 | 1 | Dual 2-wire connection system (120 volts only) | Dual stator power windings; grounded neutral | Figure 1 — Connection for 120 Volts Only; jumper between circuit breakers must be removed when connecting for 120/240 volts |
| 120 | 1 | Dual 2-wire connection system from dual stator AC power windings (Figure 1) | Dual stator AC power windings; grounded neutral | Used where units power only 120 volts AC loads |
| 120 | 1-Phase | Factory connection for 120 volts AC only | T1 (red), T3 (black), T2 (white) | Neutral is grounded. |
| 120 | single | 120 volts only — dual 2-wire connection with jumper between circuit breakers installed | | Figure 1 connection for 120 volts only; grounded neutral |
| 120 volts AC | 1-Phase | Factory wired for 120 volts AC only; grounded neutral | T1 (red), T2 (white), T3 (black); stator leads 11, 33, 22, 44 | CB1 and CB2 line breakers |
| 120 volts only | 1 | jumper installed between circuit breakers | T1/T2/T3/T4, neutral | stator dual 2-wire connection system |
| 120 volts only | single | jumper wire installed between circuit breakers for 120/240V reconnection | T1/T2/T3/T4, grounded neutral | dual stator AC power windings, dual 2-wire connection system; neutral grounded |
| 120/208 | 3-Phase | parallel wye | S1 through S12; bolted junctions: 1: S4,S5,S6,S10,S11,S12 = Neutral (00); 2: S1 and S7 = Line E1; 3: S2 and S8 = Line E2; 4: S3 and S9 = Line E3 | Voltage Code B |
| 120/240 | | Dual voltage AC output (reconnection) | Stator output leads 11P and 44 form the two hot leads (T1 Red and T3 Black); junction of leads 22P and 33 forms the neutral (T2 White) | Neutral line remains grounded. Remove the jumper wire between the two main circuit breakers. Existing breakers may be re-used, or a 2-pole breaker rated closer to unit capacity may be installed. |
| 120/240 | 1 | Reconnect dual stator windings for dual voltage output; remove the jumper between the circuit breakers | Dual stator AC power windings | All units are reconnectable to 120 and/or 240 volts, dual voltage output. Units are not listed per RVIA/ANSI when reconnected for dual voltage output. Replacement line breakers consist of two separate breakers with a connecting piece between the handles. |
| 120/240 | 1 | Reconnectable dual voltage output | Dual stator power windings | All units are reconnectable to 120 and/or 240 volts, dual voltage output; units are not listed per RVIA/ANSI when reconnected for dual voltage output |
| 120/240 | 1 | Reconnected for dual voltage AC output | Dual stator power windings | Be sure to remove the jumper between the circuit breakers when connecting for 120/240 volts. If reconnected for dual voltage, the unit is no longer RVIA listed. |
| 120/240 | 1-Phase | 3-wire | Leads 11 and 44 form hot lines; junction of Leads 22 and 33 forms neutral | Voltage Code A |
| 120/240 | 1-Phase | Reconnected for dual voltage output | T1 (red) hot, T3 (black) hot, T2 (white) neutral | Neutral is grounded. Connect stator leads 22 and 33 together and route to grounding terminal (GT). Connect stator a-c output leads 11 and 44 to the 2-pole circuit breaker. |
| 120/240 | 1-Phase or 3-Phase | delta connected | Two of six stator coils are double-wound; connect 240 volts AC loads across Lines E1 and E2; connect 120 volts AC loads across Lines E1 to 00 or E3 to 00 | Voltage Code D |
| 120/240 | single | Dual voltage output — remove the jumper between the circuit breakers | | Units are not listed per RVIA/ANSI when reconnected for dual voltage output; replacement line breakers consist of two separate breakers with a connecting piece between handles |
| 120/240 volts AC | 1-Phase | Reconnected for dual voltage output; grounded neutral | Connect stator leads 11 and 44 to 2-pole breaker; attach T1 (red) and T3 (black); connect stator leads 22 and 33 together and route to grounding terminal (GT) | Neutral is grounded |
| 120/240V | 1 | dual voltage output | 11P and 44 hot; 22P and 33 neutral | Neutral remains grounded; jumper removed; may use 2-pole breaker |
| 120V | 1 | single voltage output | 11P,22P,33,44 | Factory connected; jumper between main circuit breakers |