Generac GT-999 Engine Engine
The Generac GT-999 is a 1 L 2-cylinder engine rated at 3600 rpm. It powers generator sets from Generac, including the G0070420 and GT-530. It holds 1.8 L (0.5 gal) of oil.
Also known as: Generac GT-999, GT-999
Engine specifications
| Oil capacity | 1.8 L |
|---|
| Displacement | 0.999 L |
|---|
| Cylinders | 2 |
|---|
| Rated speed | 3600 rpm |
|---|
Generator sets powered by this engine
2
Common problems
15- DANGER 000001
- Problem 22 – Battery is Dead Battery is Dead
Fix: Test 45 – Check Battery and Cables - Problem 21 – No Low Speed Exercise No Low Speed Exercise
- Problem 20 – Generator Will Not Exercise Generator Will Not Exercise
Fix: Test 45 – Check Battery and Cables - Engine Will Not Crank When Utility Power Source Fails Evolution E-Code 2400
Fix: Test 44 – Check 7.5 Amp Fuse Evolution Alarm Code 2400 - Wiring Error ALARM 2099
- Voltage and Frequency Drop Excessively When Loads Are Applied
Fix: TEST 14 - CHECK VOLTAGE AND FREQUENCY UNDER LOAD, BOTH LOW -> TEST 15 - CHECK FOR OVERLOAD CONDITION, NOT OVERLOADED -> GOOD -> IF RECONFIGURED TO LP GAS, VERIFY THAT PROPER PROCEDURE WAS FOLLOWED (REFER TO INSTALLATION MANUAL), GOOD -> OVERLOADED -> DISCONTINUE TESTING, REDUCE LOADS TO UNIT’S RATED CAPACITY, TEST 12 - CHECK STEPPER MOTOR CONTROL, GOOD -> BAD -> REPAIR OR REPLACE, LOOK FOR A SHORTED CONDITION IN A CONNECTED LOAD OR IN ONE OF THE LOAD CIRCUITS, GOOD -> TEST 7 - CHECK STATOR AC POWER WINDINGS, ENGINE CONDITION GOOD -> REPAIR OR REPLACE, BAD -> TEST 16 - CHECK ENGINE CONDITION, GOOD -> GO TO “PROBLEM 18 - ENGINE STARTS HARD AND RUNS ROUGH/LACKS POWER” SECTION 4.3 - Unstable Voltage or Incorrect Output Which is Not Triggering a Shutdown
Fix: TEST 1 - CHECK AC OUTPUT VOLTAGE, ERRATIC -> PROCEED TO PROBLEM 3 - Undervoltage 1902
- Stepper Overcurrent ALARM 2100
- RPM Sensor ALARM 1501
- Prolonged Over-Voltage Undervoltage 1900
- Overspeed ALARM
Cause: Prolonged (60 Hz on a 50 Hz unit, 72Hz on 60Hz unit) Over specified Hz for 3 seconds. Possible cause: Stepper motor/mixer body assembly issue. - Overloaded ALARM 2102
- Overload Remove Load ALARM 2399
Compiled from service & troubleshooting documentation across every generator set that uses the Generac GT-999.
Common questions
What is the oil capacity of the Generac GT-999?
The Generac GT-999 engine has an oil capacity of 1.8 liters.
What is the displacement of the Generac GT-999?
The Generac GT-999 has a displacement of 0.999 liters with 2 cylinders.
Which generators use the Generac GT-999 engine?
The Generac GT-999 powers 2 generator set(s), including Generac G0070420, Generac GT-530.
What is a common problem with the Generac GT-999 engine?
A commonly reported issue on generators using the Generac GT-999 is: DANGER.