HomeEnginesGenerac GT-999

Generac GT-999 Engine Engine

The Generac GT-999 is a 1 L 2-cylinder engine rated at 3600 rpm. It powers generator sets from Generac, including the G0070420 and GT-530. It holds 1.8 L (0.5 gal) of oil.

Also known as: Generac GT-999, GT-999

0.999 L
Displacement
2
Cylinders
3600 rpm
Rated speed
1.8 L
Oil capacity

Engine specifications

Oil capacity1.8 L
Displacement0.999 L
Cylinders2
Rated speed3600 rpm

Generator sets powered by this engine

2

Common problems

15
  • DANGER 000001
  • Problem 22 – Battery is Dead Battery is Dead
    Fix: Test 45 – Check Battery and Cables
  • Problem 21 – No Low Speed Exercise No Low Speed Exercise
  • Problem 20 – Generator Will Not Exercise Generator Will Not Exercise
    Fix: Test 45 – Check Battery and Cables
  • Engine Will Not Crank When Utility Power Source Fails Evolution E-Code 2400
    Fix: Test 44 – Check 7.5 Amp Fuse Evolution Alarm Code 2400
  • Wiring Error ALARM 2099
  • Voltage and Frequency Drop Excessively When Loads Are Applied
    Fix: TEST 14 - CHECK VOLTAGE AND FREQUENCY UNDER LOAD, BOTH LOW -> TEST 15 - CHECK FOR OVERLOAD CONDITION, NOT OVERLOADED -> GOOD -> IF RECONFIGURED TO LP GAS, VERIFY THAT PROPER PROCEDURE WAS FOLLOWED (REFER TO INSTALLATION MANUAL), GOOD -> OVERLOADED -> DISCONTINUE TESTING, REDUCE LOADS TO UNIT’S RATED CAPACITY, TEST 12 - CHECK STEPPER MOTOR CONTROL, GOOD -> BAD -> REPAIR OR REPLACE, LOOK FOR A SHORTED CONDITION IN A CONNECTED LOAD OR IN ONE OF THE LOAD CIRCUITS, GOOD -> TEST 7 - CHECK STATOR AC POWER WINDINGS, ENGINE CONDITION GOOD -> REPAIR OR REPLACE, BAD -> TEST 16 - CHECK ENGINE CONDITION, GOOD -> GO TO “PROBLEM 18 - ENGINE STARTS HARD AND RUNS ROUGH/LACKS POWER” SECTION 4.3
  • Unstable Voltage or Incorrect Output Which is Not Triggering a Shutdown
    Fix: TEST 1 - CHECK AC OUTPUT VOLTAGE, ERRATIC -> PROCEED TO PROBLEM 3
  • Undervoltage 1902
  • Stepper Overcurrent ALARM 2100
  • RPM Sensor ALARM 1501
  • Prolonged Over-Voltage Undervoltage 1900
  • Overspeed ALARM
    Cause: Prolonged (60 Hz on a 50 Hz unit, 72Hz on 60Hz unit) Over specified Hz for 3 seconds. Possible cause: Stepper motor/mixer body assembly issue.
  • Overloaded ALARM 2102
  • Overload Remove Load ALARM 2399

Compiled from service & troubleshooting documentation across every generator set that uses the Generac GT-999.

Common questions

What is the oil capacity of the Generac GT-999?

The Generac GT-999 engine has an oil capacity of 1.8 liters.

What is the displacement of the Generac GT-999?

The Generac GT-999 has a displacement of 0.999 liters with 2 cylinders.

Which generators use the Generac GT-999 engine?

The Generac GT-999 powers 2 generator set(s), including Generac G0070420, Generac GT-530.

What is a common problem with the Generac GT-999 engine?

A commonly reported issue on generators using the Generac GT-999 is: DANGER.