Cummins/Onan KTAK4-2100 Engine Engine
The Cummins/Onan KTAK4-2100 is a 18.8 L 6-cylinder turbocharged and aftercooled engine rated at 1800 rpm. It powers generator sets from Cummins/Onan, including the DFE. It holds 45.4 L (12.0 gal) of oil and 90.8 L (24.0 gal) of coolant.
Also known as: Cummins KTAK4-2100
Engine specifications
| Oil capacity | 45.4 L |
|---|
| Coolant capacity | 90.8 L |
|---|
| Displacement | 18.8 L |
|---|
| Cylinders | 6 |
|---|
| Aspiration | turbocharged and aftercooled |
|---|
| Rated speed | 1800 rpm |
|---|
Generator sets powered by this engine
1
Common problems
15- Over Current 1471
- Low AC Voltage 2331
- High AC Voltage 2358
- Weak Battery 1442
- Warning, Shutdown, and Non-Automatic lamps are not lit. Digital display shows main menu or selected menu.
Cause: Indicates all engine systems are normal. No corrective action required - Warning lamp lights.
Cause: LOW COOLANT TEMP 210 – WARNING
Fix: Set is in standby mode but is not operating. Warning occurs when engine coolant temperature is 70° F (21° C) or lower. NOTE: In applications where the ambient temperature falls below 40°F (4°C), Low Engine Temp may be indicated even though the coolant heaters are operating. - Under Frequency 1448
- Too Long in Idle 2342
- The light will display the fault codes (active or inactive) in succession, starting with the most recent. Up to 32 (unacknowledged) fault codes can be stored in control panel memory. 213
- Speed/Hz Match 1469
- Speed Signal Lost 121
- Shutdown lamp lights. 212
Cause: Indicates engine has overheated (coolant temperature has risen above the shutdown trip point: 223° F – standby / 215° F – primary) or the coolant level is low. Allow engine to cool down completely before proceeding with the following checks:
Fix: A. Check coolant level and replenish if low. Look for coolant leakage and repair if necessary. b. Check for obstructions to cooling airflow and correct as necessary. c. Check fan belt and repair or tighten if necessary. d. Reset control and restart after locating and correcting problem. Contact an authorized service center if none of the above. - Shutdown After Battle Short 1123
- Short Circuit 1445
- Remote Emergency Stop 1434
Compiled from service & troubleshooting documentation across every generator set that uses the Cummins/Onan KTAK4-2100.
Maintenance schedule
| Item | Spec | Capacity | Part # | Interval | |
|---|
| Air filter | | | — | 1000 hr | find |
| Fuel filter | | | — | 500 hr | find |
| Oil filter | | | — | 1000 hr | find |
| Coolant | | 90.8 L | — | 540 hr | |
| Oil | | 45.4 L | — | | |
Pooled from every document that names this exact engine — confirm the interval and part number against your unit's serial number.
Common questions
What is the oil capacity of the Cummins/Onan KTAK4-2100?
The Cummins/Onan KTAK4-2100 engine has an oil capacity of 45.4 liters.
What is the displacement of the Cummins/Onan KTAK4-2100?
The Cummins/Onan KTAK4-2100 has a displacement of 18.8 liters with 6 cylinders.
Which generators use the Cummins/Onan KTAK4-2100 engine?
The Cummins/Onan KTAK4-2100 powers 1 generator set(s), including Cummins/Onan DFE.
What is a common problem with the Cummins/Onan KTAK4-2100 engine?
A commonly reported issue on generators using the Cummins/Onan KTAK4-2100 is: Over Current.