Generac GN-220 Engine Engine

The Generac GN-220 is a 0.22 L 1-cylinder 4-stroke engine rated at 2850 rpm. It powers generator sets from Generac and Magnum, including the IMPACT-36LPG PLUS II, Impact-34 plus, Impact-36 plus and Impact-36G. It holds 710 L (187.6 gal) of oil.

Also known as: GN-220, Generac GN-220

0.216 L
Displacement
1
Cylinders
2850 rpm
Rated speed
710.0 L
Oil capacity

Engine specifications

Oil capacity710.0 L
Displacement0.216 L
Cylinders1
Aspiration4-stroke
Rated speed2850 rpm

Generator sets powered by this engine

7

Shared across brands: Generac, Magnum

Common problems

15
  • Start/Stop switch at Stop, engine continues to run.
    Cause: Defective Start/Stop switch
    Fix: Replace switch.
  • Low Voltage Shutdown M04
  • High Temperature Shutdown M02
  • Engine starts, shuts down when Start/Stop switch is released.
    Cause: Engine oil is low.
    Fix: Check oil; add as needed.
  • Engine won't crank.
    Cause: 15 amp fuse is blown.
    Fix: Replace 15 amp fuse.
  • Engine cranks but won't start.
    Cause: Out of fuel.
    Fix: Replenish fuel.
  • Overspeed Shutdown M03
    Fix: Do not attempt a manual adjustment to control engine speed.
  • Low Oil Pressure Shutdown M01
    Fix: Check the engine oil level. If necessary, add oil to the FULL mark.
  • Engine starts hard, runs rough, low full load power.
    Cause: 1. Air cleaner plugged or damaged. 2. Defective spark plug. 3. Loose spark plug boot.
    Fix: 1. Clean or replace as needed. 2. Clean, regap or replace plug. 3. Press boot on securely.
  • No output from generator.
    Fix: Check circuit breaker. Reset to ON
  • Engine starts hard, runs rough.
    Cause: Air cleaner plugged or damaged.
    Fix: Clean or replace as needed.
  • W WARNING QA
  • Stator windings are shorted to ground
    Fix: The Stator should be cleaned and dried. The Insulation resistance tests should then be repeated. If, after cleaning and drying, the Stator again falls the test, replace the Stator assembly.
  • If the engine starts but the Stepper Motor does not move, and shutdown occurs after several seconds
    Cause: Broken or shorted Power Supply winding (Wires PS1 and PS2)
  • If the engine shuts down but speed did NOT exceed 4500 rpm
    Cause: One of the main windings (Power Phase 1 or 2) Is open

Compiled from service & troubleshooting documentation across every generator set that uses the Generac GN-220.

Maintenance schedule

ItemSpecCapacityPart #Interval
Air filterreplace element0D3262250 hr Amazon eBay PartsGeek
Fuel filter0D7515400 hr Amazon eBay PartsGeek
Oil filter070185100 hr Amazon eBay $19.97 PartsGeek
Oil24.0 oz5W-3025 hr PartsGeek

Pooled from every document that names this exact engine — confirm the interval and part number against your unit's serial number.

Common questions

What is the oil capacity of the Generac GN-220?

The Generac GN-220 engine has an oil capacity of 710.0 liters.

What is the displacement of the Generac GN-220?

The Generac GN-220 has a displacement of 0.216 liters with 1 cylinders.

Which generators use the Generac GN-220 engine?

The Generac GN-220 powers 7 generator set(s), including Generac IMPACT-36LPG PLUS II, Generac Impact-34 plus, Generac Impact-36 plus, Generac Impact-36G, Generac NP-30G.

How often should you change the oil in the Generac GN-220?

The Generac GN-220 oil change interval is every 25 hours.

What is a common problem with the Generac GN-220 engine?

A commonly reported issue on generators using the Generac GN-220 is: Start/Stop switch at Stop, engine continues to run.. Cause: Defective Start/Stop switch. Fix: Replace switch..