Onan (status indicator switch) Controller

The Onan (status indicator switch) is a generator-set controller. It is used on generator sets from Cummins/Onan, including the 5.5 HGJAE and 6.5 HGJAE.

4
Generator sets
Cummins/Onan
Brand
2
Fuel types

Generator sets using this controller

4

Also fitted to: Cummins/Onan 5.5 HGJAD/HGJAE, Cummins/Onan 7.0 HGJAD/HGJAE.

Troubleshooting

60

Fault codes

CodeMeaningCauseRemedy
1High engine coolant temperatures
12OVERVOLTAGE SHUTDOWNController unable to maintain rated voltageSee an authorized Onan dealer.
12Over Voltage — Indicates the control is unable to maintain rated voltage.Contact local dealer or distributor.
12Overvoltage
12Overvoltage shutdown — Controller unable to maintain rated voltageController unable to maintain rated voltageSee an authorized Onan dealer.
12Overvoltage — Instantaneous Fault − AC voltage S1−S2 greater than 150 VAC; Delayed Fault − AC voltage S1−S2 greater than 138 VAC, but less than 150 VAC for 3 continuous minutesGenset loads; Inverter/Charger; wire connections; AC sense transformer; windingsVerify that Last Fault is FC 12: Yes, continue diagnosis; No, troubleshoot actual last fault; Measure AC voltage; Measure AC frequency while changing engine rpm to determine if frequency response matches engine rpm response: repair damaged generator drive system as necessary; Cycle loads to determine if a particular load causes fault: diagnose faulty load as necessary; Determine Inverter/Charger battery charge rate (typical default is 80 percent): if adjustable reduce to 30 percent; Verify balanced loads in 120/240 VAC applications: balance loads within 10 percent line−to−line as required; HGJAD only − Run genset in Engine Run Only mode and externally excite field F1−F2 with 12 VDC or 24 VDC and measure main and quadrature winding AC output; Non EFI − If the genset will not stay running measure genset frequency, quadrature winding and main winding voltages using Break-Out Tool 420−0603 and Instruction Sheet R1098; Remove connector P1 from control and re-install and try to start genset: inspect, repair or replace P1 connector pins as necessary; Measure field, quadrature and main winding resistance: clean slip rings, replace brushes, repair harness and replace rotor or stator as necessary; Measure field, quadrature and main winding resistance to ground: clean slip rings, replace brushes, repair harness and replace rotor or stator as necessary; Measure field, quadrature and main winding resistance to each other: clean slip rings, replace brushes, repair harness and replace rotor or stator as necessary; Check brush alignment per PSB-682a; Dealers contact Distributor for technical support, Distributors contact factory for technical support
13AC voltage S1–S2 less than 108 VAC for 5 continuous secondsGenset loads, Inverter/Charger, wire connections, generator drive system, windings, AC sense transformer, windingsVerify that Last Fault is FC 13: Yes, continue diagnosis; No, troubleshoot actual last fault; Measure AC voltage; Measure AC voltage in and out of sense transformer (if so equipped): repair wire connection, replace sense transformer as necessary; Measure AC frequency while changing engine rpm to determine if frequency response matches engine rpm response: repair damaged generator drive system as necessary; Cycle loads to determine if a particular load will cause fault: diagnose faulty load as necessary; Determine battery charge rate (typical default is 80 percent): if adjustable reduce to 30 percent; Verify balanced loads in 120/240 VAC applications: balance loads within 10 percent line–to–line as required; HGJAD only – Run genset in Engine Run Only mode and externally excite field F1–F2 with 12 VDC or 24 VDC and measure main and quadrature winding AC output; Non EFI – If the genset will not stay running measure genset frequency, quadrature winding and main winding voltages using Break-Out Tool 420–0603 and Instruction Sheet R1098; Remove connector P1 from control and re-install and try to start genset: inspect, repair or replace P1 connector pins as necessary; Measure field, quadrature and main winding resistance: clean slip rings, replace brushes, repair harness and replace rotor or stator as necessary; Measure field, quadrature and main winding resistance to ground: clean slip rings, replace brushes, repair harness and replace rotor or stator as necessary; Measure field, quadrature and main winding resistance to each other: clean slip rings, replace brushes, repair harness and replace rotor or stator as necessary; Check brush alignment per PSB-682a; Dealers contact Distributor for technical support, Distributors contact factory for technical support
13UNDERVOLTAGE SHUTDOWNController unable to maintain rated voltageReduce the number of connected appliances, especially when air conditioners and battery chargers are running.
13Under Voltage — Indicates the control is unable to maintain rated voltage.Reduce load: reduce the number of connected appliances, especially air conditioners and battery chargers (review load management in Loading the Generator Set).
13Undervoltage shutdown — Controller unable to maintain rated voltageController unable to maintain rated voltageReduce the number of connected appliances, especially when air conditioners and battery chargers are running.
13Undervoltage — AC voltage S1−S2 less than 108 VAC for 5 continuous secondsGenset loads; Inverter/Charger; wire connections; generator drive system; windings; AC sense transformer; windingsVerify that Last Fault is FC 13: Yes, continue diagnosis; No, troubleshoot actual last fault; Measure AC voltage; Measure AC voltage in and out of sense transformer (if so equipped): repair wire connection, replace sense transformer as necessary; Measure AC frequency while changing engine rpm to determine if frequency response matches engine rpm response: repair damaged generator drive system as necessary; Cycle loads to determine if a particular load will cause fault: diagnose faulty load as necessary; Determine battery charge rate (typical default is 80 percent): if adjustable reduce to 30 percent; Verify balanced loads in 120/240 VAC applications: balance loads within 10 percent line−to−line as required; HGJAD only − Run genset in Engine Run Only mode and externally excite field F1−F2 with 12 VDC or 24 VDC and measure main and quadrature winding AC output; Non EFI − If the genset will not stay running measure genset frequency
14OVERFREQUENCY SHUTDOWNEngine governor unable to maintain rated frequencySee an authorized Onan dealer.
14Over Frequency — Indicates the engine governor is unable to maintain rated frequency.Contact local dealer or distributor.
14OverfrequencyGenset loads, Inverter/Charger, engine governor function, fuel supply, air fuel mixture, exhaust system, choke, demand regulator, carburetor, generator drive system, generator windings, ignition, wire connectionsVerify that Last Fault is FC 14: Yes, continue diagnosis; No, troubleshoot actual last fault; Measure AC current while running genset with vehicle loads: identify faulty or short cycling loads; Determine battery charge rate (typical default is 80 percent): if adjustable reduce to 30 percent; Measure genset load capability with shop load bank (derate for altitude and temperature as necessary); Measure genset frequency and droop while running; Measure AC frequency while changing engine rpm to determine if frequency response matches engine rpm response: repair damaged generator drive system as necessary; Disconnect genset control P1 connector, verify P1 pins are fully inserted and inspect pin condition per PSB–676: insert, repair or replace pins as necessary; Reconnect P1 connector and test run genset for fault occurrence: repair or replace pins in connector as necessary; Check governor, actuator, linkage and spring for debris, damage and looseness: readjust and repair as necessary; Measure field, quadrature and main winding resistance: clean slip rings, replace brushes, repair harness and replace rotor or stator as necessary; Measure field, quadrature and main winding resistance to ground: clean slip rings, replace brushes, repair harness and replace rotor or stator as necessary; Measure field, quadrature and main winding resistance to each other: clean slip rings, replace brushes, repair harness and replace rotor or stator as necessary; Check brush alignment per PSB-682a; Verify that spark plug cables are secure on spark plugs: reconnect or replace as necessary; Inspect ignition kill leads in harness and at connector P1: repair or replace lead, terminal or pins as necessary; Test Magnetos: Disconnect Connector P1. Connect positive(+) meter lead to chassis ground. HGJAA, D, E, F – Measure continuity to negative lead at pin P1–4 and P1–5: replace magnetos as necessary. HGJAB, C – Measure continuity to negative lead at pin P1–15 and P1–20: replace magnetos as necessary; Measure spark plug gap: set gap or replace spark plugs as necessary; Verify ignition spark condition; Inspect spark plug lead, kill lead terminal at magneto and measure magneto air gap: replace terminals, set gap or replace magnetos as necessary; Measure temperature of air intake and temperature rise across genset; remove blockage or prevent air recirculation; Dealers contact Distributor for technical support, Distributors contact factory for technical support
14Overfrequency shutdown — Engine governor unable to maintain rated frequencyEngine governor unable to maintain rated frequencySee an authorized Onan dealer.
15UNDERFREQUENCY SHUTDOWNEngine governor unable to maintain rated frequencyReduce the number of connected appliances, especially when air conditioners and battery chargers are running.
15Under Frequency — Indicates the engine governor is unable to maintain rated frequency.Reduce load: reduce the number of connected appliances, especially air conditioners and battery chargers (review load management in Loading the Generator Set).
15Underfrequency
15Underfrequency shutdown — Engine governor unable to maintain rated frequencyEngine governor unable to maintain rated frequencyReduce the number of connected appliances, especially when air conditioners and battery chargers are running.
17Fuel Pump Fault — Only Active Prior to 2001 − Open fuel pump circuit at controlWire connections; harness leads; faulty fuel pumpVerify that Last Fault is FC 17: Yes, continue diagnosis; No, troubleshoot actual last fault; Verify fuel pump operation in prime mode, if pump operates fault condition has been cleared verify harness connections, no further troubleshooting; HGJAA, D Check continuity across fuse F1; Disconnect genset control P1 connector, verify P1 pins are fully inserted and inspect pin condition per PSB−676: insert, repair or replace pins as necessary; Reconnect P1 connector, prime genset to verify pump operation and test run genset for fault occurrence; Measure continuity between E2 fuel pump leads; replace terminals or fuel pump as necessary; Measure voltage between fuel pump E2 + and ground while priming; replace terminals, harness leads or control as necessary
17Fuel pump faultWire connections, harness leads, faulty fuel pumpVerify that Last Fault is FC 17: Yes, continue diagnosis; No, troubleshoot actual last fault; Verify fuel pump operation in prime mode, if pump operates fault condition has been cleared verify harness connections, no further troubleshooting; HGJAA, D Check continuity across fuse F1; Disconnect genset control P1 connector, verify P1 pins are fully inserted and inspect pin condition per PSB–676: insert, repair or replace pins as necessary; Reconnect P1 connector, prime genset to verify pump operation and test run genset for fault occurrence; Measure continuity between E2 fuel pump leads; replace terminals or fuel pump as necessary; Measure voltage between fuel pump E2 + and ground while priming; replace terminals, harness leads or control as necessary
19GOVERNOR ACTUATOR SHUTDOWNController sensed open or shorted circuitSee an authorized Onan dealer.
19Governor Actuator (EFI Only) — Shorted or open connection between governor leads after pressing startWire connections; P1−17; governor actuator (Does Not Pertain to Model HGJAA)Verify that Last Fault is FC 19: Yes, continue diagnosis; No, troubleshoot actual last fault; Disconnect genset control P1 connector, verify P1 pins are fully inserted and inspect pin condition per PSB−676: insert, repair or replace pins as necessary; Reconnect P1 connector and test run genset for fault occurrence: repair or replace pins in connector as necessary; P1−17 open to ground on EFI Models: ground lead as required for carburetor configuration; Verify actuator function by applying DC voltage to terminals: replace actuator as necessary; Measure resistance between actuator terminals; repair or replace connections as necessary, replace governor actuator; Measure continuity between P1−28 and actuator lead; repair or replace terminals and leads as necessary; Measure DC voltage at actuator while starting: replace controller as necessary
19Governor Actuator — Indicates the control sensed an open or shorted circuit.Contact local dealer or distributor.
19Governor actuator (EFI only)Wire connections, P1–17, governor actuatorVerify that Last Fault is FC 19: Yes, continue diagnosis; No, troubleshoot actual last fault; Disconnect genset control P1 connector, verify P1 pins are fully inserted and inspect pin condition per PSB–676: insert, repair or replace pins as necessary; Reconnect P1 connector and test run genset for fault occurrence: repair or replace pins in connector as necessary; P1–17 open to ground on EFI Models: ground lead as required for carburetor configuration; Verify actuator function by applying DC voltage to terminals: replace actuator as necessary; Measure resistance between actuator terminals; repair or replace connections as necessary, replace governor actuator; Measure continuity between P1–28 and actuator lead; repair or replace terminals and leads as necessary; Measure DC voltage at actuator while starting: replace controller as necessary
19Governor actuator shutdown — Controller sensed open or shorted circuitController sensed open or shorted circuitSee an authorized Onan dealer.
2LOW OIL PRESSURE SHUTDOWNLow oil pressure cutoff switch did not openCheck engine oil level and add oil as necessary (Page Section 4.2); Drain excess oil (above dipstick Full mark.)
2Low Oil Pressure FaultLow/high oil level; faulty switch; faulty oil pressure relief valve; fault oil pumpVerify that Last Fault is FC 2: Yes, continue diagnosis; No, troubleshoot actual last fault; Measure oil level: add or drain oil as necessary; Disconnect genset control P1 connector, verify P1 pins are fully inserted and inspect pin condition per PSB-676: insert, repair or replace pins as necessary; Reconnect P1 connector and test run genset for fault occurrence: repair or replace pins in connector as necessary; Measure continuity change across start/stop switch between rest and under simulated pressure: replace switch as necessary; HGJAB, C — Measure continuity between ground and P1-13: repair or replace harness as necessary. HGJAA, D, E, F — Measure continuity between ground and P1-6: repair or replace harness as necessary; Measure oil pressure with mechanical gauge: repair or replace relief valve and oil pump as necessary
2Low Oil Pressure — Indicates that the low oil pressure cutoff switch did not open.Check engine oil level: if the dipstick indicates oil is low, add oil; if oil is above the full mark on dipstick, drain excess oil.
2Low oil pressure faultLow/high oil level, faulty switch, faulty oil pressure relief valve, fault oil pumpVerify that Last Fault is FC 2: Yes, continue diagnosis; No, troubleshoot actual last fault; Measure oil level: add or drain oil as necessary; Disconnect genset control P1 connector, verify P1 pins are fully inserted and inspect pin condition per PSB–676: insert, repair or replace pins as necessary; Reconnect P1 connector and test run genset for fault occurrence: repair or replace pins in connector as necessary; Measure continuity change across start/stop switch between rest and under simulated pressure: replace switch as necessary; HGJAB, C – Measure continuity between ground and P1–13: repair or replace harness as necessary. HGJAA, D, E, F – Measure continuity between ground and P1–6: repair or replace harness as necessary; Measure oil pressure with mechanical gauge: repair or replace relief valve and oil pump as necessary
2Low oil pressure shutdown — First-level shutdown code—Low oil pressure cutoff switch did not openLow oil pressure cutoff switch did not openCheck engine oil level and add oil as necessary (Page 17); Drain excess oil (above dipstick Full mark.)
22GOVERNOR ACTUATOR OVERLOAD SHUTDOWNDuration of operation at or near full-duty cycle beyond design limitReduce the number of connected appliances, especially when air conditioners and battery chargers are running; Service the air cleaner (Page Section 4.5); Check for and repair a blocked exhaust system.
22Governor Actuator Overload (EFI Only) — Only active Prior to 2001 − Maximum governor output (PWM) for 10 continuous secondsGenset loads; Inverter/Charger; wire connections; fuel supply; air fuel mixture; exhaust system; governor actuator; ignition systemVerify that Last Fault is FC 22: Yes, continue diagnosis; No, troubleshoot actual last fault; Measure AC current while running genset with vehicle loads: identify faulty or short cycling loads or reduce vehicle loads as necessary; Determine battery charge rate (typical default is 80 percent): if adjustable reduce to 30 percent; Measure genset load capability with shop load bank (derate for altitude and temperature as necessary); Measure AC frequency and droop while running; Measure AC frequency while changing engine rpm to determine if frequency response matches engine rpm response: repair damaged generator drive system as necessary; Disconnect genset control P1 connector, verify P1 pins are fully inserted and inspect pin condition per PSB−676: insert, repair or replace pins as necessary; Reconnect P1 connector and test run genset for fault occurrence: repair or replace pins in connector as necessary; Check air filter cleanliness; replace air filter as necessary; Check intake manifold and gaskets for air leaks: tighten fasteners and replace gaskets and manifold as necessary; Check for blocked or damaged exhaust system: repair or replace exhaust components as necessary; Measure fuel pump pressure/flow: replace fuel filter, pressure regulator or fuel pump as necessary; Verify actuator function by applying DC voltage to terminals: replace actuator as necessary; Check throttle body for binding; inspect spring for dirt and debris: clean spring, replace throttle body as necessary; Verify that spark plug cables are secure on spark plugs: reconnect or replace as necessary; Inspect ignition kill leads in harness and at connector P1: repair or replace lead, terminal or pins as necessary; Test Magnetos: Disconnect Connector P1; Connect positive(+) meter lead to chassis ground; HGJAA, D, E, F − Measure continuity to negative lead at pin P1−4 and P1−5: replace magnetos as necessary; HGJAB, C − Measure continuity to negative lead at pin P1−15 and P1−20: replace magnetos as necessary; Measure spark plug gap: set gap or replace spark plugs as necessary; Verify ignition spark condition; Inspect spark plug cables, kill lead terminal at magneto and measure magneto air gap: replace terminals, set gap or replace magnetos as necessary; Dealers contact Distributor for technical support, Distributors contact factory for technical support
22Governor Actuator Overload — Indicates the duration of operation is near full-duty cycle beyond design limit.Excessive load; dirty air filter element; blocked exhaust system.Reduce load: reduce the number of connected appliances, especially air conditioners and battery chargers (review load management in Loading the Generator Set); replace the air filter if dirty; if exhaust system is blocked, remove blockage.
22Governor actuator overload (EFI only)Genset loads, Inverter/Charger, wire connections, fuel supply, air fuel mixture, exhaust system, governor actuator, ignition systemVerify that Last Fault is FC 22: Yes, continue diagnosis; No, troubleshoot actual last fault; Measure AC current while running genset with vehicle loads: identify faulty or short cycling loads or reduce vehicle loads as necessary; Determine battery charge rate (typical default is 80 percent): if adjustable reduce to 30 percent; Measure genset load capability with shop load bank (derate for altitude and temperature as necessary); Measure AC frequency and droop while running; Measure AC frequency while changing engine rpm to determine if frequency response matches engine rpm response: repair damaged generator drive system as necessary; Disconnect genset control P1 connector, verify P1 pins are fully inserted and inspect pin condition per PSB–676: insert, repair or replace pins as necessary; Reconnect P1 connector and test run genset for fault occurrence: repair or replace pins in connector as necessary; Check air filter cleanliness; replace air filter as necessary; Check intake manifold and gaskets for air leaks: tighten fasteners and replace gaskets and manifold as necessary; Check for blocked or damaged exhaust system: repair or replace exhaust components as necessary; Measure fuel pump pressure/flow: replace fuel filter, pressure regulator or fuel pump as necessary; Verify actuator function by applying DC voltage to terminals: replace actuator as necessary; Check throttle body for binding; inspect spring for dirt and debris: clean spring, replace throttle body as necessary; Verify that spark plug cables are secure on spark plugs: reconnect or replace as necessary; Inspect ignition kill leads in harness and at connector P1: repair or replace lead, terminal or pins as necessary; Test Magnetos: Disconnect Connector P1. Connect positive(+) meter lead to chassis ground. HGJAA, D, E, F – Measure continuity to negative lead at pin P1–4 and P1–5: replace magnetos as necessary. HGJAB, C – Measure continuity to negative lead at pin P1–15 and P1–20: replace magnetos as necessary; Measure spark plug gap: set gap or replace spark plugs as necessary; Verify ignition spark condition; Inspect spark plug cables, kill lead terminal at magneto and measure magneto air gap: replace terminals, set gap or replace magnetos as necessary; Dealers contact Distributor for technical support, Distributors contact factory for technical support
22Governor actuator overload shutdown — Duration of operation at or near full-duty cycle beyond design limitDuration of operation at or near full-duty cycle beyond design limitReduce the number of connected appliances, especially when air conditioners and battery chargers are running; Service the air cleaner (Page 19); Check for and repair a blocked exhaust system.
23LOW OIL PRESSURE CUTOFF SWITCH SHUTDOWNController sensed switch still open during start—not a running faultSee an authorized Onan dealer.
23Low Oil Pressure Cutoff Switch — Indicates the control sensed that switch is still open during start (not a running start).Contact local dealer or distributor.
23Low oil pressure cutoff switch shutdown — Controller sensed switch still open during start—not a running faultController sensed switch still open during start—not a running faultSee an authorized Onan dealer.
23Oil Pressure Switch Fault — Only Active Prior to 2001 − Continuous open on oil pressure switch input before crankingWire connections; faulty switchVerify that Last Fault is FC 23: Yes, continue diagnosis; No, troubleshoot actual last fault; Verify harness lead is connected to switch: repair or replace terminal as necessary; Disconnect genset control P1 connector, verify P1 pins are fully inserted and inspect pin condition per: insert, repair or replace pins as necessary; Reconnect P1 connector and test run genset for fault occurrence; Measure continuity to ground at switch and through harness at P1 connector: replace switch, repair or replace harness as necessary
23Oil pressure switch faultWire connections, faulty switch
27VOLTAGE SENSE SHUTDOWNController unable to sense output voltageSee an authorized Onan dealer.
27Voltage Sense Lost
27Voltage Sense Lost — No Sense Voltage (0 VAC across S1−S2) for 1 continuous second after start disconnectGenset loads; Inverter/Charger; VAC sense transformer; engine governor function; fuel supply; choke; demand regulator; carburetor; generator windings; ignition; wire connections; temperatureVerify that Last Fault is FC 27: Yes, continue diagnosis; No, troubleshoot actual last fault; Measure AC voltage; Determine battery charge rate (typical default is 80 percent): if adjustable reduce to 30 percent; Disconnect genset control P1 connector, verify P1 pins are fully inserted and inspect pin condition per PSB−676: insert, repair or replace pins as necessary; Reconnect P1 connector and test run genset for fault occurrence: repair or replace pins in connector as necessary; Check air filter cleanliness; replace air filter as necessary; Check for blocked or damaged exhaust system: repair or replace exhaust components as necessary; HGJAD only − Run genset in Engine Run Only and externally excite field with 12 VDC or 24 VDC and measure main and quadrature winding AC output; Non EFI only
27Voltage Sense — Indicates the control is unable to sense output voltage.Contact local dealer or distributor.
27Voltage sense shutdown — Controller unable to sense output voltageController unable to sense output voltageSee an authorized Onan dealer.
29HIGH BATTERY VOLTAGE SHUTDOWNVoltage across battery system greater than 19 voltsCheck battery bank connections and reconnect if necessary so that the 12 volt batteries serving the genset are connected in parallel (12 volt) rather than in series (24 volt); Select a lower battery boost charge rate.
29High Battery Voltage
29High Battery Voltage — Indicates that voltage across the battery system is greater than 19 Volts.Check battery bank connections and reconnect if necessary so that the 12 Volt batteries serving the generator set are connected in parallel (12 Volt) rather than in series (24 Volt); select a lower battery boost charge rate.
29High battery voltageIncorrect battery configuration, wire damage, faulty charger, controlVerify that Last Fault is FC 29: Yes, continue diagnosis; No, troubleshoot actual last fault; Measure DC voltage at battery, genset and connector P1: reconnect battery or repair wiring as necessary; Measure DC voltage with battery charger on: reduce boost charge rate or diagnose faulty charger as necessary; If genset shares batteries with propulsion engine, check for fault using shop battery (voltage spike may cause fault): diagnose fault or voltage spikes from propulsion engine charging system; Disconnect genset control P1 connector, verify P1 pins are fully inserted and inspect pin condition per PSB–676: insert, repair or replace pins as necessary; Reconnect P1 connector and test run genset for fault occurrence: replace controller
29High battery voltage shutdown — Voltage across battery system greater than 19 voltsVoltage across battery system greater than 19 voltsCheck battery bank connections and reconnect if necessary so that the 12 volt batteries serving the genset are connected in parallel (12 volt) rather than in series (24 volt); Select a lower battery boost charge rate.
3SERVICE CHECK SHUTDOWNIndicates fault with second-level shutdown codeCheck the second-level shutdown code by pressing STOP once. The second-level shutdown code will have two-digits. The faults are listed in numerical order in this table.
3Service CheckSee second-level fault code.
3Service Check Fault — Single-Digit Fault to indicate shutdown due to a Two-Digit FaultAny Two-Digit Fault CodeVerify that Last Fault is FC 3: Yes, continue diagnosis; No, troubleshoot actual last fault; While LED is flashing three times press stop once (1 second duration): trouble shoot Two-Digit Fault Code
3Service check faultAny Two-Digit Fault CodeVerify that Last Fault is FC 3: Yes, continue diagnosis; No, troubleshoot actual last fault; While LED is flashing three times press stop once (1 second duration): trouble shoot Two-Digit Fault Code
3Service check shutdown — First-level shutdown code—Indicates fault with second-level shutdown codeIndicates fault with second-level shutdown codeCheck the second-level shutdown code by pressing STOP once. The second-level shutdown code will have two-digits. The faults are listed in numerical order in this table.
31OVERSPEED SHUTDOWNEngine speed greater than 3400 rpmSee an authorized Onan dealer.
31Over Speed — Indicates that engine speed is greater than 3400 RPM.Contact local dealer or distributor.
31Overspeed Fault (HGJAD, E, F Models Only)
31Overspeed fault (HGJAD, E, F models only)Engine governor function, fuel supply, air fuel mixture, exhaust system, choke, demand regulator, carburetor, generator drive system, ignition, wire connectionsVerify that Last Fault is FC 31: Yes, continue diagnosis; No, troubleshoot actual last fault; Measure genset frequency and droop while running; Measure AC frequency while changing engine rpm to determine if frequency response matches engine rpm response: repair damaged generator drive system as necessary; Disconnect genset control P1 connector, verify P1 pins are fully inserted and inspect pin condition per PSB–676: insert, repair or replace pins as necessary; Inspect spark plug lead, kill lead terminal at magneto and measure magneto air gap: replace terminals, set gap or replace magnetos as necessary; Measure temperature of air intake and temperature rise across genset; remove blockage or prevent air recirculation; Dealers contact Distributor for technical support, Distributors contact factory for technical support

Fault codes and symptom→remedy steps extracted from this controller’s service/owner documentation; verify against the official manual before servicing. Aggregated from the service documentation of generator sets built on this controller.