Home›Controllers›4 Generator

4 Generator Controller

The 4 Generator is a generator-set controller. It is used on generator sets from Northern Lights, including the M864.

2
Generator sets
Northern Lights
Brand
20–25 kW
Power range
2
Fuel types

Generator sets using this controller

2

Engines paired with this controller

1

Troubleshooting

16

Symptoms & remedies

SymptomCauseRemedy
Battery Will Not ChargeLoose or corroded connectionsClean and tighten battery connections
Below Normal Engine TemperatureThermostats not working properlyCheck thermostats
Engine Emits Black or Gray Exhaust SmokeClogged or dirty air cleanerService air cleaner
Engine Emits White SmokeImproper fuelUse correct fuel for temperature
Engine Hard to Start or Will Not StartImproper starting procedureSee starting section of this manual. Take special note of Bypass Switch operation
Engine KnocksInsufficient oilCall your dealer
Engine OverheatsEngine overloadedReduce the electrical load
Engine Runs Irregularly or Stalls FrequentlyBelow normal engine temperatureRemove and check thermostat
Entire Electrical System Does Not FunctionCheck DC circuit breakerIf breaker is tripped, reset it
High Fuel ConsumptionImproper type of fuelUse correct fuel for temperature
High Oil ConsumptionBreak-in periodOil consumption decreases after break in
Lack of Engine PowerEngine overloadedReduce the load
Low Compression PressureSee your dealer
Low Oil PressureLow oil levelFill crankcase to proper level
Starter Cranks SlowlyLow battery conditionCheck specific gravity of each battery; Check electrolyte level of each battery; Replace battery if necessary
Starter InoperativeCheck DC circuit breakerIf the breaker is tripped, reset it

Fault codes and symptom→remedy steps extracted from this controller’s service/owner documentation; verify against the official manual before servicing. Aggregated from the service documentation of generator sets built on this controller.