Cummins/Onan P1700i Troubleshooting

Cummins/Onan P1700i troubleshooting: 43 symptom-cause-remedy entries from the manufacturer's own service documentation.

Cummins/Onan P1700i — full specs, parts & maintenance.

All Cummins/Onan fault codes →

Troubleshooting

43

Symptoms & remedies

SymptomCauseRemedy
Engine fails to startEngine switch is not in its proper positionTurn engine switch to "CHOKE" position
No electricity is generated at receptacleDC circuit breaker is turned OFF
No electricity is generated at receptacleOverload Lamp is turned ON (Red)
No electricity is generated at receptacleAC receptacle and DC terminals have loose connection
No electricity is generated at receptacleEngine starting was attempted with appliances already connected
Engine fails to start — engine switch not in its proper positionEngine switch is not in its proper positionTurn engine switch to "" (CHOKE) position
Engine fails to start — fuel level lowFuel level is low/emptyIf empty, refill fuel tank making sure not to overfill
Engine fails to start — generator connected to an applianceGenerator is connected to an applianceIf connected, turn off the power switch on the connected appliance and unplug
Engine fails to start — spark plug contaminatedSpark plug contaminationRemove spark plug and clean electrode
Engine fails to start — engine oil level lowEngine oil level is lowIf the engine oil level is low, add the oil to the upper level line on the oil gauge
Engine fails to start — loose spark plug capSpark plug cap is looseIf loose, push spark plug cap back into place
No electricity is generated at receptacle — DC circuit breaker turned OFFDC circuit breaker is turned OFFDepress the circuit breaker into ON position, after making sure the electric appliances are in the normal condition
No electricity is generated at receptacle — Overload Lamp turned ON (Red)Overload Lamp is turned ON (Red)Stop the engine and check the appliances and/or generator for overloading
No electricity is generated at receptacle — loose connection at AC receptacle and DC terminalsAC receptacle and DC terminals have loose connectionSecure connection if necessary
No electricity is generated at receptacle — engine starting attempted with appliances already connectedEngine starting was attempted with appliances already connected to generatorTurn off switch on the appliance, and disconnect cable from receptacle. Reconnect after generator has been started properly
Fails To CrankLow battery.Check battery fluid level.
Fails To CrankBad battery connection.Clean & tighten all battery & cable connections.
Fails To CrankBlown fuse.Replace fuse on control panel.
Cranks SlowlyLow battery.Check battery fluid level.
Cranks SlowlyBad battery connection.Clean & tighten all battery & cable connections.
Cranks SlowlyIncorrect oil viscosity.Replace with recommended viscosity oil.
Cranks SlowlyLoad connected.Disconnect load before starting.
Cranks But Won’t StartFuel below generator pickup level in tank.Add fuel.
Cranks But Won’t StartFuel supply shutoff valve closed.Fully open fuel supply valve.
Cranks But Won’t StartCarbon deposits on spark plug(s).Remove spark plug(s) and replace.
Cranks But Won’t StartLow oil level.Add oil.
Exhausting Black SmokeDirty air filter.Replace air filter.
Exhausting Black SmokeChoke stuck or misadjusted.Contact an Cummins Onan Authorized RV Service & Parts Dealer.
Unit Runs Then Stops, Or Stops When Driving Around A CornerLow fuel level.Add fuel.
Unit Runs Then Stops, Or Stops When Driving Around A CornerLow oil level.Add oil.
Unit Runs Then Stops, Or Stops When Driving Around A CornerExcess oil.Reduce engine oil level.
Unit Starts And Runs, Then Stops When The Start Switch Is ReleasedLow fluid levels.Check & bring all fluids up to the appropriate levels.
Unit Starts And Runs, Then Stops When The Start Switch Is ReleasedPossible overheating.Check for blocked air flow or other possible causes of overheating.
Unit Starts And Runs, Then Stops When The Start Switch Is ReleasedOther functional problem.Contact an Cummins Onan Authorized RV Service & Parts Dealer.
Unit Starts And Runs, Then Stops When The Start Switch Is ReleasedNo AC output.Contact an Cummins Onan Authorized RV Service & Parts Dealer.
Unit Runs Then SurgesLoose or worn spark plug leads.Check spark plug leads at spark plug & ignition coil.
Unit Runs Then SurgesDefective ignition coil, wiring, or control components.Contact an Cummins Onan Authorized RV Service & Parts Dealer.
Unit Runs Then SurgesFaulty spark plug.Remove spark plug & clean or replace.
Unit Runs Then SurgesGovernor out of adjustment.Contact an Cummins Onan Authorized RV Service & Parts Dealer.
Unit Runs Then SurgesCombustion air pre-heat malfunction.Contact an Cummins Onan Authorized RV Service & Parts Dealer.
Unit Runs Then SurgesCarburetor icing.Move carburetor pre-heater to the winter position.
Unit Runs Then SurgesCarburetor varnishing.Try fuel system cleaner and contact dealer if no change.
Circuit Breaker TripsOverloaded circuit.Turn-off some of the electrical load, and reset the circuit breaker.

Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing.

Common questions

Cummins/Onan P1700i: Unit Runs Then Surges — what causes it?

Documented causes: Loose or worn spark plug leads.; Defective ignition coil, wiring, or control components.; Faulty spark plug.; Governor out of adjustment.. See the table for the matching fixes.

Cummins/Onan P1700i: No electricity is generated at receptacle — what causes it?

Documented causes: DC circuit breaker is turned OFF; Overload Lamp is turned ON (Red); AC receptacle and DC terminals have loose connection; Engine starting was attempted with appliances already connected. See the table for the matching fixes.

Cummins/Onan P1700i: Cranks Slowly — what causes it?

Documented causes: Low battery.; Bad battery connection.; Incorrect oil viscosity.; Load connected.. See the table for the matching fixes.