Home TroubleshootingCummins/Onan DQHAB

Cummins/Onan DQHAB Troubleshooting

Cummins/Onan DQHAB troubleshooting: 56 fault codes and symptom-cause-remedy entries from the manufacturer's own service documentation.

Cummins/Onan DQHAB — full specs, parts & maintenance.

All Cummins/Onan fault codes →

Troubleshooting

56

Fault codes

CodeMeaning
121Speed Signal Lost
135Oil Pressure Sensor High
141Oil Pressure Sensor Low
143Pre-Low Oil Pressure Sensor
144Coolant Temperature Sensor High
145Coolant Temperature Sensor Low
146Pre-High Cool Temp
151High Coolant Temp
197Low Coolant Level
234Overspeed
235Low Coolant Level
359Fail to Start
415Low Oil Pressure
441Low Battery Voltage
442High Battery Voltage
1123Shutdown After Battle Short
1124Delayed Shutdown
1131Battle Short Active
1244Engine Normal Shutdown
1311Customer Inputs #1
1312Customer Inputs #2
1317Customer Inputs #3
1318Customer Inputs #4
1334Crit Scaler OR
1335Non-Crit Scaler OR
1416Fail to Shutdown
1417Power Down Failure
1433Emergency Stop
1434Remote Emergency Stop
1435Low Coolant Temperature
1438Fail to Crank
1442Weak Battery
1443Battery Failed
1444KW Overload
1445Short Circuit
1446High AC Voltage
1447Low AC Voltage
1448Under Frequency
1449Over Frequency
1461Loss of Field
1466Modem Failure
1468Network Error
1469Speed/Hz Match
1471Over Current
1472Over Current
2335Excitation Fault
2336Memory Error
2341High Control Temperature
2342Too Long in Idle
2967Governor Fault
2968AVR Fault
2969LON Failure
2972Field Overload

Symptoms & remedies

SymptomCauseRemedy
Generator does not startFault Code 101 - Starter Motor FaultCheck starter motor connections and replace if necessary
Engine runs roughFault Code 203 - Fuel System FaultInspect fuel filter and injectors, clean or replace as needed
Generator produces low voltage outputFault Code 304 - Alternator Winding FaultCheck alternator windings for damage and repair or replace if necessary

Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing.

Cross-brand guides for these symptoms

Common questions

Cummins/Onan DQHAB: Generator does not start — what causes it?

Documented causes: Fault Code 101 - Starter Motor Fault. See the table for the matching fixes.

Cummins/Onan DQHAB: Engine runs rough — what causes it?

Documented causes: Fault Code 203 - Fuel System Fault. See the table for the matching fixes.

Cummins/Onan DQHAB: Generator produces low voltage output — what causes it?

Documented causes: Fault Code 304 - Alternator Winding Fault. See the table for the matching fixes.