Home TroubleshootingCummins/Onan 600 DFX-4R

Cummins/Onan 600 DFX-4R Troubleshooting

Cummins/Onan 600 DFX-4R troubleshooting: 8 fault codes and symptom-cause-remedy entries from the manufacturer's own service documentation.

Cummins/Onan 600 DFX-4R — full specs, parts & maintenance.

All Cummins/Onan fault codes →

Troubleshooting

8

Symptoms & remedies

SymptomRemedy
Fault lamp lights and engine stops cranking after approximately 75-seconds.See engine service manual for troubleshooting fuel system. After correcting fault, reset engine monitor relay by placing Run-Stop/Reset-Remote switch to Stop/Reset position, depressing Reset button, then to the required running position.
Engine runs, shuts down, cranks for 75-seconds, cranking cycle stops, light ON.Check fuel supply.
"Low oil pressure shutdown."Check— a. Oil level. Replenish if necessary. b. Sensor. Faulty sensor will shut down engine. c. Refer to engine service manual for troubleshooting guide for oil system.
"High engine temperature shutdown."Check— a. Coolant level. Replenish is necessary. b. City water cooled sets. Check water flow, valves, etc. c. Check sensor; check thermostat.
DizzinessGet out into fresh air immediately.
Weakness and SleepinessGet out into fresh air immediately.
VomitingGet out into fresh air immediately.
Muscular TwitchingGet out into fresh air immediately.

Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing.