Home›Repair guides›Yanmar›Turbocharger Turbine Cleaning (MET18, 900/1000 min-1, solid cleaning)

Yanmar — Turbocharger Turbine Cleaning (MET18, 900/1000 min-1, solid cleaning)

Maintenance

From a Yanmar manual — check it applies to your exact model before use.

Browse Yanmar generators & specs →

Before you start

  • Excessive quantity of cleaning agent can cause surging.
  • Periodic disassembly servicing must be implemented separately.

Procedure

  1. Adjust engine load to about 75% and turbine inlet temperature below 510 °C.
  2. Open valves in order (1) then (3) then (4); circulate air for 0.5-1 minute to cool.
  3. Close valves in order (4) then (3) then (1).
  4. Fill specified amount of solid cleaning agent into tank (2); close cap firmly.
  5. Open valves (1) then (3) then (4) to pass air and fill the cleaning agent.
  6. Close valves in order (4) then (2) then (1).

Specs & values

  • Solid cleaning agent 0.05-0.1 l per one time
  • Marine grit #10, grain dia. 1.7-2.4 mm (Walnut-shell)
  • General service air 0.4-1.0 MPa

Source: Yanmar manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.