Home›Repair guides›Wisconsin›Solid State Ignition Distributor Testing (Voltmeter)

Wisconsin — Solid State Ignition Distributor Testing (Voltmeter)

Testing & diagnosis

From a Wisconsin service manual covering: FM-X4B7D, V-460D, V-461D, V-465D, V460D, V461D, V465, Y-128-S1, YB-85A. Check it applies to your exact model before use.

Browse Wisconsin generators & specs →

Before you start

  • Disconnect ground (negative) cable when charging battery.
  • Do not reverse battery cables; negative ground system only.

Procedure

  1. Connect voltmeter positive lead to negative side of ignition coil; ground negative lead; set to DC volts on at least 15 volt scale.
  2. Disconnect high voltage wire from center of distributor cap and ground it to engine block or chassis.
  3. Crank engine.
  4. Voltmeter should fluctuate from 1 to 2 volts to 10 to 12 volts as engine is cranked.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Voltmeter fluctuation 1 to 2 volts to 10 to 12 volts
  • Constant 0 reading = open primary circuit
  • Constant 1.0 to 3.5 volts = electronic module shorted
  • Constant battery voltage = module open circuit, replace

Source: Wisconsin service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.