Home›Repair guides›Wisconsin›Fuel Pump Priming

Wisconsin — Fuel Pump Priming

Operation

From a Wisconsin service manual covering: FM-X4B7D, V-460D, V-461D, V-465D, V460D, V461D, V465, Y-128-S1, YB-85A. Check it applies to your exact model before use.

Browse Wisconsin generators & specs →

Procedure

  1. Move hand primer lever up and down; distinct resistance of diaphragm should be felt.
  2. If not, turn engine one revolution so fuel pump drive cam rotates from upper position.
  3. Assuming strainer is empty, approximately 25 strokes required to fill bowl.
  4. After strainer bowl full, additional 5 to 10 strokes fill carburetor bowl.
  5. When carburetor is full, hand primer lever moves more easily.

Source: Wisconsin service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.