Home›Repair guides›Winco›Storage Preparation (over 30 days)

Winco WL16000HE-03/A — Storage Preparation (over 30 days)

Maintenance · fuel system

For the Winco WL16000HE-03/A, from the Winco service manual.

Browse Winco generators & specs →

Procedure

  1. Add fuel stabilizer and run 2 minutes to circulate
  2. Optionally drain remaining fuel into approved container
  3. Run engine until fuel in carburetor/lines is used up and engine stops
  4. Drain oil while warm and refill with fresh oil
  5. Clean dirt and chaff from cylinder, fins, blower housing, screen, muffler
  6. Store in a clean, dry area

Source: Winco service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.