Winco HPS9000VE-03/A — Electric Starting (LP/NG)
Operation · engine
For the Winco HPS9000VE-03/A, from the Winco service manual.
Browse Winco generators & specs →
Before you start
- Almost impossible to manual start using NG
Procedure
- Check oil level, refill as needed
- Turn on the LP/NG fuel supply
- NEVER use the choke when operating on NG
- Turn the engine switch to ON
- Rotate the key switch briefly to START; do not operate starter more than 5 seconds, wait 10 seconds between attempts
- When the engine starts, release the key switch
- The engine should promptly come up to operating speed
Source: Winco service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.