Procedure
- With engine running, turn off the gasoline valve
- Run the engine until it runs out of fuel
- Remove the plastic insert from the demand regulator
- Install a locally approved flexible fuel line
- Connect the LP/NG fuel line to the flexible fuel line
- Ensure hose is attached to proper fitting (LP or NG)
- Turn on the vapor fuel
- Start the engine
- Apply the load to the generator
Source: Winco service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.