Before you start

  • Never store with fuel in tank near ignition sources

Procedure

  1. Clean the generator
  2. Drain gasoline from fuel tank as best as possible
  3. With fuel valve open, run engine until fuel in lines/carburetor is consumed and engine shuts off
  4. Close fuel shutoff valve
  5. Change the oil
  6. Remove spark plug, add about 1 tablespoon of oil into spark plug opening, pull recoil handle several times
  7. Replace spark plug
  8. Move generator to clean, dry storage place

Source: Westinghouse owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.