Home›Repair guides›Westinghouse›Cleaning the Spark Arrestor

Westinghouse WH5500 — Cleaning the Spark Arrestor

Maintenance · Exhaust System

For the Westinghouse WH5500, from the Westinghouse owner's manual.

Browse Westinghouse generators & specs →

Before you start

  • Do not operate engine with spark arrestor screen removed

Procedure

  1. Stop generator and allow to cool several minutes.
  2. Move generator to flat surface.
  3. Use flat-head screwdriver to loosen spark arrestor band clamp.
  4. Slide band clamp off spark arrestor screen.
  5. Pull spark arrestor screen out of muffler exhaust tube.
  6. Use wire brush to remove dirt and residue from screen.
  7. If screen shows signs of wear (torn, broken, large holes), replace it.
  8. Reinstall spark arrestor screen on muffler exhaust tube base.
  9. Reinstall band clamp over screen and tighten with screwdriver.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Source: Westinghouse owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Westinghouse repair guides →