Before you start

  • Gasoline stored for as little as 60 days can go bad, causing gum/varnish/corrosive buildup.

Procedure

  1. Clean the generator.
  2. Drain all gasoline from the fuel tank as best as possible.
  3. With the fuel shutoff valve open, run the engine until remaining gasoline is consumed and engine shuts off.
  4. Close the fuel shutoff valve.
  5. Change the oil.
  6. Remove the spark plug and place about 1 tablespoon of oil in the spark plug opening; pull the recoil handle to turn the engine over several times.
  7. Replace the spark plug.
  8. Move the generator to a clean, dry place for storage.

Source: Westinghouse owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.