Procedure
- Stop inverter and let cool.
- Move inverter to flat, level surface.
- Remove four screws holding muffler cover in place.
- Loosen clamp holding spark arrestor onto muffler.
- Slide spark arrestor band clamp off spark arrestor screen.
- Pull spark arrestor screen off muffler exhaust pipe.
- Remove dirt/debris with wire brush; replace if worn (rips, tears, large openings).
- Reinstall spark arrestor screen and band clamp.
Tools required
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Source: Westinghouse owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.