Home›Repair guides›Westinghouse›Storing Generator

Westinghouse — Storing Generator

Maintenance

From a Westinghouse owner's manual covering: WGen2000, WGen3600, WGen5500, WGen6500st, WGen7500, WGen8300st. Check it applies to your exact model before use.

Browse Westinghouse generators & specs →

Before you start

  • Never store a generator with fuel in the tank indoors or near an ignition source

Procedure

  1. Press in the Battery Disconnect button on electric start units
  2. Clean the generator
  3. Drain all gasoline from the fuel tank as best as possible
  4. With fuel shut-off valve open, run the engine until remaining fuel is consumed and it shuts off
  5. Close the fuel shut-off valve
  6. Change the oil
  7. Remove the spark plug and place about 1 tablespoon of oil in the opening, then turn the engine over several times
  8. Replace the spark plug
  9. Move the generator to a clean, dry storage location

Source: Westinghouse owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Westinghouse repair guides →