Procedure
- Stop generator and let it cool
- Move generator to a flat, level surface
- Loosen spark arrestor band clamp with a flathead screwdriver
- Slide band clamp off spark arrestor screen
- Pull spark arrestor screen off the muffler exhaust pipe
- Remove dirt and debris with a wire brush
- Replace screen if worn (rips, tears, large openings)
- Reinstall screen over muffler exhaust pipe
- Reinstall and tighten band clamp
Tools required
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Source: Westinghouse owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.