Home›Repair guides›Westerbeke›Torquing Cylinder Head Bolts

Westerbeke — Torquing Cylinder Head Bolts

Repair & overhaul

From a Westerbeke operator's manual covering: 16.0 BEDA, 20.0 BED, 25.0 BED, 32.0 BEDA. Check it applies to your exact model before use.

Applies to: Westerbeke 20.0 BED, Westerbeke 25.0 BED

Procedure

  1. Make sure the engine is cold.
  2. Loosen one head bolt one-half turn, then tighten to 85 to 90 lb-ft (11.8 to 12.5 kg/m) for BED 20KW and 25KW.
  3. Tighten the cylinder head bolts according to the sequence shown in the illustration.
  4. The 32 KW head bolts do NOT require retorquing.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • 85 to 90 lb-ft (11.8 to 12.5 kg/m)

Full service-parts list: Westerbeke 20.0 BED →, Westerbeke 25.0 BED →

Source: Westerbeke operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.