Home›Repair guides›Westerbeke›Lay-Up and Recommissioning

Westerbeke — Lay-Up and Recommissioning

Maintenance · Engine and generator

From a Westerbeke operator's manual covering: 16.0 BEDA, 20.0 BED, 25.0 BED, 32.0 BEDA. Check it applies to your exact model before use.

Applies to: Westerbeke 20.0 BED, Westerbeke 25.0 BED

Before you start

  • Do not leave old engine oil in the sump over the lay-up period.

Procedure

  1. Drain all engine oil, replace the oil filter and fill sump with new oil.
  2. Top off fuel tank with No. 2D diesel and add fuel additives; change filter/water separator element.
  3. Flush raw water circuit with fresh water then antifreeze solution.
  4. Remove raw water pump impeller; store it and replace cover with a new gasket.
  5. Check and clean or replace zinc anode; clear zinc debris from heat exchanger.
  6. For long lay-up (12 months or more), remove glow plugs and squirt oil into cylinders.
  7. Rotate crankshaft by hand two revolutions and re-install glow plugs.
  8. At recommissioning, install impeller, reconnect batteries, check zinc anode and start engine.

Specs & values

  • Lay-up cylinder lubrication for lay-up of 12 months or more

Full service-parts list: Westerbeke 20.0 BED →, Westerbeke 25.0 BED →

Source: Westerbeke operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Westerbeke repair guides →