Procedure

  1. Drive out old diode with a suitable drift.
  2. Install replacement diode with a deep well socket catching the outside edge.
  3. Use a C-clamp to press it into the generator housing.
  4. Maintain good alignment and diode contact with the housing.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Two diodes (#32609)

Source: Westerbeke service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.