Westerbeke — Bridge Rectifier Test Procedures

Testing & diagnosis

From a Westerbeke service manual covering: WTA 15, WTA 20, WTA 25, WTA12KW, WTA15KW, WTA16KW, WTAl5KW. Check it applies to your exact model before use.

Procedure

  1. Remove the main rotor DC connection at the ground or at the soldered DC output (red dot).
  2. Set ohmmeter on low scale Rx1.
  3. Connect plus lead to DC lead (red dot); contact points 1,2,3,4 with negative; no deflection should occur.
  4. Reverse connections; contact points 1,2,3,4 with plus; half to three-quarter scale deflection should occur.
  5. Points 1,2,3 read 8-9 ohm; point 4 reads 30-40 ohm.
  6. If readings between points 1,2,3 vary, remove rectifier and test independently.